Testing Portal everyone (auth disabled)

Serial lookup

Search a serial number to see its full test history.

Serial C00000444

Tests4
Approved1
Failures3

Tests over time

Test history

DateMeasurement IDID recordArticleResult
2026-02-23 09:37 53734 639074361995034762-9388 S0003591 Fail View
2026-02-23 09:37 53735 639074362454293481-7725 S0003591 Fail View
2026-02-23 09:38 53736 639074363076240340-3995 S0003591 Fail View
2026-02-23 09:40 53737 639074363733324210-1716 S0003591 Pass View

Test 53735

Result
Fail
Date
2026-02-23 09:37
Article
S0003591
ID record
639074362454293481-7725
ID production
Temperature
Humidity
Test duration
26
Error ID
218
Error text
TestSW: test oscilátoru ON

Measurement lines

StepNameValueMinMaxResult
1.1.1 DMM: Měření odporu: R1 (TP5/TP4) 5631.86433 5320 5880 Pass
1.1.2 DMM: Měření odporu: R2 (TP5/TP6) 1002.15573 950 1050 Pass
1.2.1 DMM: Měření odporu: F1 (TP9/TP8) 0.395512012 < 2 Pass
1.2.2 DMM: Měření odporu: F2 (TP10/TP11) 0.629761342 < 2.5 Pass
1.2.3 DMM: Měření odporu: R3+R4 (TP10/TP8) 1411027.44 120000 1540000 Pass
2.2.1 DMM: Měření napětí: +5V StepDown Output (TP2/TP13) 5.17556448 4 6 Pass
2.2.2 DMM: Měření napětí: +3V3 LDO Output (TP2/TP14) 3.28733894 2.64 3.96 Pass
2.2.3 DMM: Měření napětí: +3V3 Modem AVCC (TP2/TP16) 3.27973377 2.64 3.96 Pass
2.2.4 DMM: Měření napětí: +3V3 VDDA (TP2/TP22) 3.27790715 2.64 3.96 Pass
2.2.5 DMM: Měření napětí: +1V8 Audio (TP2/TP24) 1.79862404 1.44 2.16 Pass
2.2.6 DMM: Měření napětí: +12V Bed Interface Power (TP2/TP28) 11.9866221 9.6 14.4 Pass
2.3.1 AC1: Měření proudu: Kontrola odběru 0.0233113 < 0.12 Pass
2.3.2 DMM: Měření napětí: +12V ACDC měnič (TP2/TP12) 11.9616774 11.4 12.6 Pass

Measurements over time

Hover for exact values · drag to zoom · double-click to reset

Readings (4)
DateValueMinMax
2026-02-23 09:37 1002.197 950 1050
2026-02-23 09:37 1002.156 950 1050
2026-02-23 09:38 1002.194 950 1050
2026-02-23 09:40 1002.11 950 1050