| Date | Measurement ID | ID record | Article | Result | |
|---|---|---|---|---|---|
| 2026-02-23 09:19 | 53718 | 639074351350239323-5895 | S0003591 | Fail | View |
| 2026-02-23 09:20 | 53719 | 639074351853715199-5715 | S0003591 | Pass | View |
Test 53718
- Result
- Fail
- Date
- 2026-02-23 09:19
- Article
- S0003591
- ID record
- 639074351350239323-5895
- ID production
- Temperature
- Humidity
- Test duration
- 31
- Error ID
- 295
- Error text
- DMM: Měření zkratu: RE5 - NC (TP43/TP42) SHORT
Measurement lines
| Step | Name | Value | Min | Max | Result |
|---|---|---|---|---|---|
| 1.1.2 | DMM: Měření odporu: R2 (TP5/TP6) | 998.403836 | 950 | 1050 | Pass |
| 1.1.1 | DMM: Měření odporu: R1 (TP5/TP4) | 5602.52499 | 5320 | 5880 | Pass |
| 1.2.1 | DMM: Měření odporu: F1 (TP9/TP8) | 1.00669457 | < | 2 | Pass |
| 1.2.2 | DMM: Měření odporu: F2 (TP10/TP11) | 0.643552501 | < | 2.5 | Pass |
| 1.2.3 | DMM: Měření odporu: R3+R4 (TP10/TP8) | 1266863.94 | 120000 | 1540000 | Pass |
| 2.2.1 | DMM: Měření napětí: +5V StepDown Output (TP2/TP13) | 5.12904218 | 4 | 6 | Pass |
| 2.2.2 | DMM: Měření napětí: +3V3 LDO Output (TP2/TP14) | 3.29837159 | 2.64 | 3.96 | Pass |
| 2.2.3 | DMM: Měření napětí: +3V3 Modem AVCC (TP2/TP16) | 3.29169687 | 2.64 | 3.96 | Pass |
| 2.2.4 | DMM: Měření napětí: +3V3 VDDA (TP2/TP22) | 3.2969281 | 2.64 | 3.96 | Pass |
| 2.2.5 | DMM: Měření napětí: +1V8 Audio (TP2/TP24) | 1.8013002 | 1.44 | 2.16 | Pass |
| 2.2.6 | DMM: Měření napětí: +12V Bed Interface Power (TP2/TP28) | 11.9925579 | 9.6 | 14.4 | Pass |
| 2.3.1 | AC1: Měření proudu: Kontrola odběru | 0.0212418 | < | 0.12 | Pass |
| 2.3.2 | DMM: Měření napětí: +12V ACDC měnič (TP2/TP12) | 11.985658 | 11.4 | 12.6 | Pass |
| 3.2.1 | DMM: Měření frekvence: 1kHz (TP2/TP17) | 1000.01399 | 999.8 | 1000.2 | Pass |
| 3.3.1 | DMM: Měření proudu: LEDR (TP25/TP27) | -1.78905689E-08 | < | 0.0005 | Pass |
| 3.3.2 | DMM: Měření proudu: LEDR (TP25/TP27) | 0.0343376413 | 0.015 | 0.05 | Pass |
| 3.3.3 | DMM: Měření proudu: LEDR (TP25/TP27) | -1.75858529E-08 | < | 0.0005 | Pass |
| 3.3.4 | DMM: Měření proudu: LEDG (TP25/TP27) | 5.41627098E-08 | < | 0.0005 | Pass |
| 3.3.5 | DMM: Měření proudu: LEDG (TP25/TP27) | 0.0340637153 | 0.015 | 0.05 | Pass |
| 3.3.6 | DMM: Měření proudu: LEDG (TP25/TP27) | -1.84337335E-08 | < | 0.0005 | Pass |
| 3.4.1 | DMM: Měření proudu: (TP29/TP27) | 0.00098174062 | < | 0.0013 | Pass |
| 3.4.2 | DMM: Měření proudu: (TP34/TP27) | 0.000979753977 | < | 0.0013 | Pass |
| 3.5.1 | NZ3.1: Měření proudu: Kontrola odběru | 0.005065446 | < | 0.01 | Pass |
| 3.5.2 | NZ3.1: Měření proudu: Kontrola odběru | 0.005103684 | < | 0.01 | Pass |
| 3.6.1 | DMM: Měření zkratu: RE5 - NC (TP43/TP42) OPEN | 9.9E+37 | > | 1000000 | Pass |
| 3.6.2 | DMM: Měření zkratu: RE5 - NC (TP43/TP42) SHORT | 1.09739857 | < | 1 | Fail |
Measurements over time
Hover for exact values · drag to zoom · double-click to reset
Readings (2)
| Date | Value | Min | Max |
|---|---|---|---|
| 2026-02-23 09:19 | 998.404 | 950 | 1050 |
| 2026-02-23 09:20 | 998.398 | 950 | 1050 |