Testing Portal everyone (auth disabled)

Serial lookup

Search a serial number to see its full test history.

Serial 000397419

Tests5
Approved1
Failures4

Tests over time

Test history

DateMeasurement IDID recordArticleResult
2024-09-19 13:09 323 638623409313806683-6276 S0001055 Fail View
2024-09-23 07:10 450 638626649815576238-9883 S0001055 Fail View
2024-09-24 15:25 537 638627810668299299-3316 S0001055 Fail View
2024-09-24 15:27 538 638627812260821170-2169 S0001055 Fail View
2024-12-05 14:35 5328 638690024581447780-9733 S0001055 Pass View

Test 537

Result
Fail
Date
2024-09-24 15:25
Article
S0001055
ID record
638627810668299299-3316
ID production
49267
Temperature
27,06
Humidity
42,62
Test duration
48
Error ID
309
Error text
DMM: Měření napětí (TP49/TP58)

Measurement lines

StepNameValueMinMaxResult
0.3 Uložení teploty okolí 27,06 Pass
0.4 Uložení vlhkosti okolí 42,62 Pass
0.5 Uložení Id testeru (uloženo na lokálním disku) Vez_Hokami_01-v01.01 Pass
0.6 Uložení id Artiklu (produktové číslo) S0001055 Pass
1.1 DMM: Kontrola hodnoty Odporu (TP6/TP4) 0,574230344 < 10 Pass
1.2 DMM: Kontrola hodnoty Odporu (TP6/TP5) 999,081254 800 1200 Pass
3.1 NZ3.1: Měření napětí: Zkrat? 28,00851 > 27,9 Pass
3.2 NZ3.1: Měření proudu: Kontrola odběru 0,0004227014 < 0,005 Pass
3.3 R11.12: Zapnutí (TP42/TP43) Pass
3.4 NZ3.1: Měření napětí: Zkrat? 28,00851 > 27,9 Pass
3.5 NZ3.1: Měření proudu: Kontrola odběru 0,02402105 < 0,04 Pass
4.1 DMM: Měření napětí: +BATT (TP49/TP44) 27,9683746 27,9 28,1 Pass
4.2 DMM: Měření napětí: +BATT (TP49/TP34) 27,9983497 27,9 28,1 Pass
4.3 DMM: Měření napětí: +12V (TP49/TP46) 11,8726193 11 12,2 Pass
4.4 DMM: Měření napětí: +5V (TP49/TP7) 4,99667672 4,9 5,1 Pass
4.5 DMM: Měření napětí: +3V3 (TP49/TP16) 3,30764556 3,2 3,4 Pass
4.6 DMM: Měření napětí: VDDA +3V3 (TP49/TP2) 3,30765591 3,2 3,4 Pass
4.7 DMM: Měření napětí: (TP49/TP8) 4,67666479 4,57 4,77 Pass
4.8 DMM: Měření napětí: (TP49/TP9) 4,67466201 4,57 4,77 Pass
4.9 DMM: Měření napětí: (TP49/TP10) 4,67264849 4,57 4,77 Pass
5.1 DMM: Měření napětí: (TP49/TP46) 0,520626741 < 1 Pass
5.2 DMM: Měření napětí: (TP49/TP46) 11,7999326 > 11,5 Pass
6.1 R9.12: Vypnutí (TP49/TP28) Pass
7.1 NZ3: Měření napětí: Zkrat? 28,00851 > 27,9 Pass
7.2 NZ3: Měření proudu: Kontrola odběru 0,02541786 < 0,06 Pass
7.3 R0.6: Zapnutí Ext. Programátoru Pass
8.1 TestSw: Ověření komunikace [TYP:AA NAME:eDrive NAME2:TestSW HW:Kolecko v4 SW: Pass
9.1 TestSW: [CHG_SIG (PC14)] = log1? 16384 16384 16384 Pass
9.2 EL1.1: Ověření proudu na zátěži -> Current? 2,14642 1,6 2,8 Pass
9.3 DMM: Měření napětí: Vstup U14 (TP39/TP32) 29,6649636 29 30,1 Pass
9.4 DMM: Měření napětí: Vstup U14 (TP39/TP33) 11,2714175 10,8 11,5 Pass
9.5 DMM: Měření napětí: Vstup U14 (TP39/TP40) 1,62900535 1,5 1,8 Pass
10.1 NZ3.1: Měření napětí: Zkrat? 28,00851 > 27,9 Pass
10.2 NZ3.1: Měření proudu: Kontrola odběru 0,025521 < 0,06 Pass
10.3 TestSW: [ADC_PA03] 3851 3667 3937 Pass
12.1 TestSW: [PA15] - napájení sense ABC Pass
12.2 TestSW: [HALL_A (PB4)] = log0? 0 0 0 Pass
12.3 TestSW: [HALL_A (PB4)] = log1? 16 16 16 Pass
12.4 TestSW: [HALL_B (PB5)] = log0? 0 0 0 Pass
12.5 TestSW: [HALL_B (PB5)] = log1? 32 32 32 Pass
12.6 TestSW: [HALL_C (PB0)] = log0? 0 0 0 Pass
12.7 TestSW: [HALL_C (PB0)] = log1? 1 1 1 Pass
13.1 TestSW: [CON_ID (PC13)] = log1? 8192 8192 8192 Pass
13.10 TestSW: [BTN_FFWD][ADC_PA6]? 4086 4000 4096 Pass
13.11 TestSW: [BTN_FFWD][ADC_PA6]? 2018 1900 2100 Pass
13.12 TestSW: [BTN_STOP][ADC_PA5]? 4086 4000 4096 Pass
13.13 TestSW: [BTN_STOP][ADC_PA5]? 2010 1900 2100 Pass
13.2 TestSW: [CON_ID (PC13)] = log0? 0 0 0 Pass
13.3 TestSW: [BTN_DRV][PA11] na log1 Pass
13.4 TestSW: [BTN_FWD][ADC_PB1]? 4086 4000 4096 Pass
13.5 TestSW: [BTN_FWD][ADC_PB1]? 2010 1900 2100 Pass
13.6 TestSW: [BTN_REV][ADC_PA4]? 4086 4000 4096 Pass
13.7 TestSW: [BTN_REV][ADC_PA4]? 2003 1900 2100 Pass
13.8 TestSW: [BTN_ULCK][ADC_PA7]? 4086 4000 4096 Pass
13.9 TestSW: [BTN_ULCK][ADC_PA7]? 2030 1900 2100 Pass
14.1 TestSW: [LED1][PB2] na log1 Pass
14.10 DMM: Měření napětí: LED3 (TP49/TP14) 3,30390329 > 3 Pass
14.11 TestSW: [LED3][PB11] na log0 Pass
14.12 DMM: Měření napětí: LED3 (TP49/TP14) 0,00341227156 < 0,1 Pass
14.13 TestSW: [LED4][PB12] na log1 Pass
14.14 DMM: Měření napětí: LED4 (TP49/TP12) 3,30510796 > 3 Pass
14.15 TestSW: [LED4][PB12] na log0 Pass
14.16 DMM: Měření napětí: LED4 (TP49/TP12) 0,00338244033 < 0,1 Pass
14.2 DMM: Měření napětí: LED1 (TP49/TP13) 3,30363952 > 3 Pass
14.3 TestSW: [LED1][PB2] na log0 Pass
14.4 DMM: Měření napětí: LED1 (TP49/TP13) 0,00352532575 < 0,1 Pass
14.5 TestSW: [LED2][PB10] na log1 Pass
14.6 DMM: Měření napětí: LED1 (TP49/TP11) 3,30384939 > 3 Pass
14.7 TestSW: [LED2][PB10] na log0 Pass
14.8 DMM: Měření napětí: LED1 (TP49/TP11) 0,00342827086 < 0,1 Pass
14.9 TestSW: [LED3][PB11] na log1 Pass
15.1 TestSW: ntc 64 49 90 Pass
16.1 DMM: Měření frekvence (TP49/TP55) 19995,1343 19600 20400 Pass
16.2 DMM: Měření frekvence (TP49/TP56) 19995,1348 19600 20400 Pass
16.3 DMM: Měření napětí (TP49/TP52) 14,0095527 13,3 14,7 Pass
17.1 DMM: Měření frekvence (TP49/TP61) 19995,1268 19600 20400 Pass
17.2 DMM: Měření frekvence (TP49/TP62) 19995,1306 19600 20400 Pass
17.3 DMM: Měření napětí (TP49/TP58) -0,168588745 13,3 14,7 Fail

Measurements over time

Hover for exact values · drag to zoom · double-click to reset

Readings (5)
DateValueMinMax
2024-09-19 13:09 26.34
2024-09-23 07:10 25.52
2024-09-24 15:25 27.06
2024-09-24 15:27 27.06
2024-12-05 14:35 25.79