Serial C00000421

Tests3
Approved2
Failures1

Tests over time

Test history

DateMeasurement IDID recordArticleResult
2026-02-19 11:50 53503 639070985845307236-6128 S0003591 Pass View
2026-02-19 13:15 53547 639071036867081719-4420 S0003591 Fail View
2026-02-19 13:16 53548 639071037363983058-5368 S0003591 Pass View

Test 53547

Result
Fail
Date
2026-02-19 13:15
Article
S0003591
ID record
639071036867081719-4420
ID production
Temperature
Humidity
Test duration
16
Error ID
208
Error text
Vyhodnocení programu: [testSW]

Measurement lines

StepNameValueMinMaxResult
1.1.1 DMM: Měření odporu: R1 (TP5/TP4) 5620.16182 5320 5880 Pass
1.1.2 DMM: Měření odporu: R2 (TP5/TP6) 999.697167 950 1050 Pass
1.2.1 DMM: Měření odporu: F1 (TP9/TP8) 0.653261339 < 2 Pass
1.2.2 DMM: Měření odporu: F2 (TP10/TP11) 0.654892366 < 2.5 Pass
1.2.3 DMM: Měření odporu: R3+R4 (TP10/TP8) 1200978.86 120000 1540000 Pass
2.2.1 DMM: Měření napětí: +5V StepDown Output (TP2/TP13) 5.20821565 4 6 Pass
2.2.2 DMM: Měření napětí: +3V3 LDO Output (TP2/TP14) 3.28777077 2.64 3.96 Pass
2.2.3 DMM: Měření napětí: +3V3 Modem AVCC (TP2/TP16) 3.28020202 2.64 3.96 Pass
2.2.4 DMM: Měření napětí: +3V3 VDDA (TP2/TP22) 3.26370415 2.64 3.96 Pass
2.2.5 DMM: Měření napětí: +1V8 Audio (TP2/TP24) 1.7983953 1.44 2.16 Pass
2.2.6 DMM: Měření napětí: +12V Bed Interface Power (TP2/TP28) 11.9728305 9.6 14.4 Pass
2.3.1 AC1: Měření proudu: Kontrola odběru 0.00820398 < 0.12 Pass
2.3.2 DMM: Měření napětí: +12V ACDC měnič (TP2/TP12) 11.9335168 11.4 12.6 Pass

Measurements over time

Hover for exact values · drag to zoom · double-click to reset

Readings (3)
DateValueMinMax
2026-02-19 11:50 999.694 950 1050
2026-02-19 13:15 999.697 950 1050
2026-02-19 13:16 999.683 950 1050