Testing Portal everyone (auth disabled)

Serial lookup

Search a serial number to see its full test history.

Serial C00000344

Tests3
Approved1
Failures2

Tests over time

Test history

DateMeasurement IDID recordArticleResult
2026-02-16 11:47 53445 639068392111226388-9866 S0003591 Fail View
2026-02-16 11:48 53446 639068392668099733-3553 S0003591 Fail View
2026-02-16 11:54 53451 639068396285005123-1783 S0003591 Pass View

Test 53446

Result
Fail
Date
2026-02-16 11:48
Article
S0003591
ID record
639068392668099733-3553
ID production
Temperature
Humidity
Test duration
16
Error ID
208
Error text
Vyhodnocení programu: [testSW]

Measurement lines

StepNameValueMinMaxResult
1.1.1 DMM: Měření odporu: R1 (TP5/TP4) 5595.21892 5320 5880 Pass
1.1.2 DMM: Měření odporu: R2 (TP5/TP6) 999.243431 950 1050 Pass
1.2.1 DMM: Měření odporu: F1 (TP9/TP8) 0.663513655 < 2 Pass
1.2.2 DMM: Měření odporu: F2 (TP10/TP11) 0.895898 < 2.5 Pass
1.2.3 DMM: Měření odporu: R3+R4 (TP10/TP8) 1407923.6 120000 1540000 Pass
2.2.1 DMM: Měření napětí: +5V StepDown Output (TP2/TP13) 5.19973299 4 6 Pass
2.2.2 DMM: Měření napětí: +3V3 LDO Output (TP2/TP14) 3.28670058 2.64 3.96 Pass
2.2.3 DMM: Měření napětí: +3V3 Modem AVCC (TP2/TP16) 3.27871433 2.64 3.96 Pass
2.2.4 DMM: Měření napětí: +3V3 VDDA (TP2/TP22) 3.27688784 2.64 3.96 Pass
2.2.5 DMM: Měření napětí: +1V8 Audio (TP2/TP24) 1.79623391 1.44 2.16 Pass
2.2.6 DMM: Měření napětí: +12V Bed Interface Power (TP2/TP28) 11.9863104 9.6 14.4 Pass
2.3.1 AC1: Měření proudu: Kontrola odběru 0.0104039 < 0.12 Pass
2.3.2 DMM: Měření napětí: +12V ACDC měnič (TP2/TP12) 11.9413253 11.4 12.6 Pass

Measurements over time

Hover for exact values · drag to zoom · double-click to reset

Readings (3)
DateValueMinMax
2026-02-16 11:47 999.292 950 1050
2026-02-16 11:48 999.243 950 1050
2026-02-16 11:54 999.274 950 1050