Serial lookup
Search a serial number to see its full test history.
Serial C00000359
Tests6
Approved1
Failures5
Tests over time
Test history
| Date | Measurement ID | ID record | Article | Result | |
|---|---|---|---|---|---|
| 2026-02-16 10:38 | 53423 | 639068350935161766-6814 | S0003591 | Fail | View |
| 2026-02-16 10:39 | 53424 | 639068351492464657-6958 | S0003591 | Fail | View |
| 2026-02-16 10:40 | 53425 | 639068352049572160-7103 | S0003591 | Fail | View |
| 2026-02-16 10:41 | 53426 | 639068352790256198-5876 | S0003591 | Fail | View |
| 2026-02-16 10:42 | 53427 | 639068353285555304-8110 | S0003591 | Fail | View |
| 2026-02-16 10:47 | 53431 | 639068356069120092-1904 | S0003591 | Pass | View |
Test 53425
- Result
- Fail
- Date
- 2026-02-16 10:40
- Article
- S0003591
- ID record
- 639068352049572160-7103
- ID production
- Temperature
- Humidity
- Test duration
- 36
- Error ID
- 306
- Error text
- DMM: Měření zkratu: RE6 - BE (TP45/TP44) SHORT
Measurement lines
| Step | Name | Value | Min | Max | Result |
|---|---|---|---|---|---|
| 1.1.2 | DMM: Měření odporu: R2 (TP5/TP6) | 1001.0491 | 950 | 1050 | Pass |
| 1.1.1 | DMM: Měření odporu: R1 (TP5/TP4) | 5608.68279 | 5320 | 5880 | Pass |
| 1.2.1 | DMM: Měření odporu: F1 (TP9/TP8) | 0.658616132 | < | 2 | Pass |
| 1.2.2 | DMM: Měření odporu: F2 (TP10/TP11) | 0.893592786 | < | 2.5 | Pass |
| 1.2.3 | DMM: Měření odporu: R3+R4 (TP10/TP8) | 1410115.16 | 120000 | 1540000 | Pass |
| 2.2.4 | DMM: Měření napětí: +3V3 VDDA (TP2/TP22) | 3.28679554 | 2.64 | 3.96 | Pass |
| 2.2.6 | DMM: Měření napětí: +12V Bed Interface Power (TP2/TP28) | 11.9888614 | 9.6 | 14.4 | Pass |
| 2.2.5 | DMM: Měření napětí: +1V8 Audio (TP2/TP24) | 1.79898352 | 1.44 | 2.16 | Pass |
| 2.2.3 | DMM: Měření napětí: +3V3 Modem AVCC (TP2/TP16) | 3.28842865 | 2.64 | 3.96 | Pass |
| 2.2.2 | DMM: Měření napětí: +3V3 LDO Output (TP2/TP14) | 3.29590239 | 2.64 | 3.96 | Pass |
| 2.2.1 | DMM: Měření napětí: +5V StepDown Output (TP2/TP13) | 5.18324014 | 4 | 6 | Pass |
| 2.3.1 | AC1: Měření proudu: Kontrola odběru | 0.0156488 | < | 0.12 | Pass |
| 2.3.2 | DMM: Měření napětí: +12V ACDC měnič (TP2/TP12) | 11.9456529 | 11.4 | 12.6 | Pass |
| 3.2.1 | DMM: Měření frekvence: 1kHz (TP2/TP17) | 1000.01521 | 999.8 | 1000.2 | Pass |
| 3.3.1 | DMM: Měření proudu: LEDR (TP25/TP27) | -3.93831182E-08 | < | 0.0005 | Pass |
| 3.3.6 | DMM: Měření proudu: LEDG (TP25/TP27) | -4.36809567E-08 | < | 0.0005 | Pass |
| 3.3.5 | DMM: Měření proudu: LEDG (TP25/TP27) | 0.034736457 | 0.015 | 0.05 | Pass |
| 3.3.4 | DMM: Měření proudu: LEDG (TP25/TP27) | -4.01813646E-08 | < | 0.0005 | Pass |
| 3.3.3 | DMM: Měření proudu: LEDR (TP25/TP27) | -4.37028768E-08 | < | 0.0005 | Pass |
| 3.3.2 | DMM: Měření proudu: LEDR (TP25/TP27) | 0.035005553 | 0.015 | 0.05 | Pass |
| 3.4.1 | DMM: Měření proudu: (TP29/TP27) | 0.000974448875 | < | 0.0013 | Pass |
| 3.4.2 | DMM: Měření proudu: (TP34/TP27) | 0.000978600034 | < | 0.0013 | Pass |
| 3.5.1 | NZ3.1: Měření proudu: Kontrola odběru | 0.005147743 | < | 0.01 | Pass |
| 3.5.2 | NZ3.1: Měření proudu: Kontrola odběru | 0.005083065 | < | 0.01 | Pass |
| 3.6.1 | DMM: Měření zkratu: RE5 - NC (TP43/TP42) OPEN | 9.9E+37 | > | 1000000 | Pass |
| 3.6.2 | DMM: Měření zkratu: RE5 - NC (TP43/TP42) SHORT | 0.41252724 | < | 1 | Pass |
| 3.6.3 | DMM: Měření zkratu: RE5 - NC (TP43/TP42) OPEN | 9.9E+37 | > | 1000000 | Pass |
| 3.6.4 | DMM: Měření zkratu: RE6 - BE (TP45/TP44) OPEN | 9.9E+37 | > | 1000000 | Pass |
| 3.6.5 | DMM: Měření zkratu: RE6 - BE (TP45/TP44) SHORT | 2.97538045 | < | 1 | Fail |
Measurements over time
Hover for exact values · drag to zoom · double-click to reset
Readings (6)
| Date | Value | Min | Max |
|---|---|---|---|
| 2026-02-16 10:38 | 1001.156 | 950 | 1050 |
| 2026-02-16 10:39 | 1001.073 | 950 | 1050 |
| 2026-02-16 10:40 | 1001.049 | 950 | 1050 |
| 2026-02-16 10:41 | 1000.978 | 950 | 1050 |
| 2026-02-16 10:42 | 1001.03 | 950 | 1050 |
| 2026-02-16 10:47 | 1001.087 | 950 | 1050 |