Testing Portal everyone (auth disabled)

Serial lookup

Search a serial number to see its full test history.

Serial C00000390

Tests2
Approved1
Failures1

Tests over time

Test history

DateMeasurement IDID recordArticleResult
2026-02-16 10:01 53391 639068328623603656-3445 S0003591 Fail View
2026-02-16 10:02 53392 639068328999083302-7974 S0003591 Pass View

Test 53391

Result
Fail
Date
2026-02-16 10:01
Article
S0003591
ID record
639068328623603656-3445
ID production
Temperature
Humidity
Test duration
3
Error ID
115
Error text
DMM: Měření odporu: F2 (TP10/TP11)

Measurement lines

StepNameValueMinMaxResult
1.1.1 DMM: Měření odporu: R1 (TP5/TP4) 5592.90591 5320 5880 Pass
1.1.2 DMM: Měření odporu: R2 (TP5/TP6) 999.82903 950 1050 Pass
1.2.1 DMM: Měření odporu: F1 (TP9/TP8) 0.630088817 < 2 Pass
1.2.2 DMM: Měření odporu: F2 (TP10/TP11) 5.05690705 < 2.5 Fail

Measurements over time

Hover for exact values · drag to zoom · double-click to reset

Readings (2)
DateValueMinMax
2026-02-16 10:01 999.829 950 1050
2026-02-16 10:02 999.832 950 1050