Serial C00000382

Tests3
Approved1
Failures2

Tests over time

Test history

DateMeasurement IDID recordArticleResult
2026-02-16 09:42 53375 639068317354279140-3997 S0003591 Fail View
2026-02-16 09:43 53376 639068318058076877-1130 S0003591 Fail View
2026-02-16 09:45 53377 639068318687219218-1541 S0003591 Pass View

Test 53376

Result
Fail
Date
2026-02-16 09:43
Article
S0003591
ID record
639068318058076877-1130
ID production
Temperature
Humidity
Test duration
26
Error ID
218
Error text
TestSW: test oscilátoru ON

Measurement lines

StepNameValueMinMaxResult
1.1.1 DMM: Měření odporu: R1 (TP5/TP4) 5604.46769 5320 5880 Pass
1.1.2 DMM: Měření odporu: R2 (TP5/TP6) 1000.37956 950 1050 Pass
1.2.1 DMM: Měření odporu: F1 (TP9/TP8) 0.710204177 < 2 Pass
1.2.2 DMM: Měření odporu: F2 (TP10/TP11) 0.884085681 < 2.5 Pass
1.2.3 DMM: Měření odporu: R3+R4 (TP10/TP8) 1425907.94 120000 1540000 Pass
2.2.1 DMM: Měření napětí: +5V StepDown Output (TP2/TP13) 5.121188 4 6 Pass
2.2.2 DMM: Měření napětí: +3V3 LDO Output (TP2/TP14) 3.29509047 2.64 3.96 Pass
2.2.3 DMM: Měření napětí: +3V3 Modem AVCC (TP2/TP16) 3.28854954 2.64 3.96 Pass
2.2.4 DMM: Měření napětí: +3V3 VDDA (TP2/TP22) 3.2937356 2.64 3.96 Pass
2.2.5 DMM: Měření napětí: +1V8 Audio (TP2/TP24) 1.79560819 1.44 2.16 Pass
2.2.6 DMM: Měření napětí: +12V Bed Interface Power (TP2/TP28) 11.9933219 9.6 14.4 Pass
2.3.1 AC1: Měření proudu: Kontrola odběru 0.0209683 < 0.12 Pass
2.3.2 DMM: Měření napětí: +12V ACDC měnič (TP2/TP12) 11.9012716 11.4 12.6 Pass

Measurements over time

Hover for exact values · drag to zoom · double-click to reset

Readings (3)
DateValueMinMax
2026-02-16 09:42 1000.386 950 1050
2026-02-16 09:43 1000.38 950 1050
2026-02-16 09:45 1000.357 950 1050