Testing Portal everyone (auth disabled)

Serial lookup

Search a serial number to see its full test history.

Serial 000797152

Tests14
Approved1
Failures13

Tests over time

Test history

DateMeasurement IDID recordArticleResult
2024-09-19 12:33 346 638623387300018643-6041 S0001055 Fail View
2024-09-19 12:41 347 638623392208302988-5790 S0001055 Fail View
2024-09-19 12:42 348 638623392950854439-6507 S0001055 Fail View
2024-12-05 14:32 5333 638690022816728924-1879 S0001055 Fail View
2024-12-05 14:39 5334 638690027102964199-6831 S0001055 Fail View
2025-07-16 11:29 22214 638882549124900138-9377 S0001055 Fail View
2025-07-16 11:30 22215 638882549876914365-8935 S0001055 Fail View
2025-07-16 11:32 22216 638882550717837208-7445 S0001055 Fail View
2025-07-16 11:34 22217 638882551977991212-6980 S0001055 Fail View
2025-07-16 11:35 22218 638882552795311921-6176 S0001055 Pass View
2025-11-06 16:54 40578 638980412336203268-1311 S0001055 Fail View
2026-07-09 16:50 77822 639192125584608437-3885 S0001055 Fail View
2026-07-09 16:51 77823 639192126238100578-2421 S0001055 Fail View
2026-07-09 16:52 77824 639192126896309818-4343 S0001055 Fail View

Test 5333

Result
Fail
Date
2024-12-05 14:32
Article
S0001055
ID record
638690022816728924-1879
ID production
46078
Temperature
25,87
Humidity
30,76
Test duration
55
Error ID
371
Error text
TestSW: [ADC_PA1] sense B

Measurement lines

StepNameValueMinMaxResult
0.3 Uložení teploty okolí 25,87 Pass
0.4 Uložení vlhkosti okolí 30,76 Pass
0.5 Uložení Id testeru (uloženo na lokálním disku) Vez_Hokami_01-v01.01 Pass
0.6 Uložení id Artiklu (produktové číslo) S0001055 Pass
1.1 DMM: Kontrola hodnoty Odporu (TP6/TP4) 0,604157691 < 10 Pass
1.2 DMM: Kontrola hodnoty Odporu (TP6/TP5) 999,432388 800 1200 Pass
3.1 NZ3.1: Měření napětí: Zkrat? 28,00851 > 27,9 Pass
3.2 NZ3.1: Měření proudu: Kontrola odběru 0,00056415 < 0,005 Pass
3.3 R11.12: Zapnutí (TP42/TP43) Pass
3.4 NZ3.1: Měření napětí: Zkrat? 28,00851 > 27,9 Pass
3.5 NZ3.1: Měření proudu: Kontrola odběru 0,02442182 < 0,04 Pass
4.1 DMM: Měření napětí: +BATT (TP49/TP44) 27,9550899 27,9 28,1 Pass
4.2 DMM: Měření napětí: +BATT (TP49/TP34) 27,994928 27,9 28,1 Pass
4.3 DMM: Měření napětí: +12V (TP49/TP46) 11,8941532 11 12,2 Pass
4.4 DMM: Měření napětí: +5V (TP49/TP7) 5,01546139 4,9 5,1 Pass
4.5 DMM: Měření napětí: +3V3 (TP49/TP16) 3,30314271 3,2 3,4 Pass
4.6 DMM: Měření napětí: VDDA +3V3 (TP49/TP2) 3,30316504 3,2 3,4 Pass
4.7 DMM: Měření napětí: (TP49/TP8) 4,69457546 4,57 4,77 Pass
4.8 DMM: Měření napětí: (TP49/TP9) 4,69154029 4,57 4,77 Pass
4.9 DMM: Měření napětí: (TP49/TP10) 4,69142838 4,57 4,77 Pass
5.1 DMM: Měření napětí: (TP49/TP46) 0,51936779 < 1 Pass
5.2 DMM: Měření napětí: (TP49/TP46) 11,8207227 > 11,5 Pass
6.1 R9.12: Vypnutí (TP49/TP28) Pass
7.1 NZ3: Měření napětí: Zkrat? 28,00851 > 27,9 Pass
7.2 NZ3: Měření proudu: Kontrola odběru 0,02525283 < 0,06 Pass
7.3 R0.6: Zapnutí Ext. Programátoru Pass
8.1 TestSw: Ověření komunikace [TYP:AA NAME:eDrive NAME2:TestSW HW:Kolecko v4 SW: Pass
9.1 TestSW: [CHG_SIG (PC14)] = log1? 16384 16384 16384 Pass
9.2 EL1.1: Ověření proudu na zátěži -> Current? 2,069423 1,6 2,8 Pass
9.3 DMM: Měření napětí: Vstup U14 (TP39/TP32) 29,6417695 29 30,1 Pass
9.4 DMM: Měření napětí: Vstup U14 (TP39/TP33) 11,3218368 10,8 11,5 Pass
9.5 DMM: Měření napětí: Vstup U14 (TP39/TP40) 1,61845884 1,5 1,8 Pass
10.1 NZ3.1: Měření napětí: Zkrat? 28,00851 > 27,9 Pass
10.2 NZ3.1: Měření proudu: Kontrola odběru 0,0249552 < 0,06 Pass
10.3 TestSW: [ADC_PA03] 3861 3667 3937 Pass
12.1 TestSW: [PA15] - napájení sense ABC Pass
12.2 TestSW: [HALL_A (PB4)] = log0? 0 0 0 Pass
12.3 TestSW: [HALL_A (PB4)] = log1? 16 16 16 Pass
12.4 TestSW: [HALL_B (PB5)] = log0? 0 0 0 Pass
12.5 TestSW: [HALL_B (PB5)] = log1? 32 32 32 Pass
12.6 TestSW: [HALL_C (PB0)] = log0? 0 0 0 Pass
12.7 TestSW: [HALL_C (PB0)] = log1? 1 1 1 Pass
13.1 TestSW: [CON_ID (PC13)] = log1? 8192 8192 8192 Pass
13.10 TestSW: [BTN_FFWD][ADC_PA6]? 4086 4000 4096 Pass
13.11 TestSW: [BTN_FFWD][ADC_PA6]? 2001 1900 2100 Pass
13.12 TestSW: [BTN_STOP][ADC_PA5]? 4086 4000 4096 Pass
13.13 TestSW: [BTN_STOP][ADC_PA5]? 1999 1900 2100 Pass
13.2 TestSW: [CON_ID (PC13)] = log0? 0 0 0 Pass
13.3 TestSW: [BTN_DRV][PA11] na log1 Pass
13.4 TestSW: [BTN_FWD][ADC_PB1]? 4085 4000 4096 Pass
13.5 TestSW: [BTN_FWD][ADC_PB1]? 2014 1900 2100 Pass
13.6 TestSW: [BTN_REV][ADC_PA4]? 4086 4000 4096 Pass
13.7 TestSW: [BTN_REV][ADC_PA4]? 2008 1900 2100 Pass
13.8 TestSW: [BTN_ULCK][ADC_PA7]? 4086 4000 4096 Pass
13.9 TestSW: [BTN_ULCK][ADC_PA7]? 2007 1900 2100 Pass
14.1 TestSW: [LED1][PB2] na log1 Pass
14.10 DMM: Měření napětí: LED3 (TP49/TP14) 3,29937898 > 3 Pass
14.11 TestSW: [LED3][PB11] na log0 Pass
14.12 DMM: Měření napětí: LED3 (TP49/TP14) 0,00341319267 < 0,1 Pass
14.13 TestSW: [LED4][PB12] na log1 Pass
14.14 DMM: Měření napětí: LED4 (TP49/TP12) 3,30068789 > 3 Pass
14.15 TestSW: [LED4][PB12] na log0 Pass
14.16 DMM: Měření napětí: LED4 (TP49/TP12) 0,00340135034 < 0,1 Pass
14.2 DMM: Měření napětí: LED1 (TP49/TP13) 3,29913468 > 3 Pass
14.3 TestSW: [LED1][PB2] na log0 Pass
14.4 DMM: Měření napětí: LED1 (TP49/TP13) 0,00351757161 < 0,1 Pass
14.5 TestSW: [LED2][PB10] na log1 Pass
14.6 DMM: Měření napětí: LED1 (TP49/TP11) 3,29930478 > 3 Pass
14.7 TestSW: [LED2][PB10] na log0 Pass
14.8 DMM: Měření napětí: LED1 (TP49/TP11) 0,00342061282 < 0,1 Pass
14.9 TestSW: [LED3][PB11] na log1 Pass
15.1 TestSW: ntc 59 49 90 Pass
16.1 DMM: Měření frekvence (TP49/TP55) 19995,1287 19600 20400 Pass
16.2 DMM: Měření frekvence (TP49/TP56) 19995,1287 19600 20400 Pass
16.3 DMM: Měření napětí (TP49/TP52) 14,0076282 13,3 14,7 Pass
17.1 DMM: Měření frekvence (TP49/TP61) 19995,1211 19600 20400 Pass
17.2 DMM: Měření frekvence (TP49/TP62) 19995,1268 19600 20400 Pass
17.3 DMM: Měření napětí (TP49/TP58) 14,0063289 13,3 14,7 Pass
18.1 DMM: Měření frekvence (TP49/TP67) 19995,1211 19600 20400 Pass
18.2 DMM: Měření frekvence (TP49/TP68) 19995,1249 19600 20400 Pass
18.3 DMM: Měření napětí (TP49/TP58) 14,0082741 13,3 14,7 Pass
19.1 DMM: Měření napětí: +5V (TP49/TP7) 0,00160585552 < 0,5 Pass
20.0.3 TestSW: [ADC_PA2] sense C do var VC = 2281 Pass
20.0.7 Analysis: VC VC[2281] 2210 2340 Pass
20.0.6 Analysis: VB VB[2270] 2210 2340 Pass
20.0.5 Analysis: VA VA[2271] 2210 2340 Pass
20.0.2 TestSW: [ADC_PA1] sense B do var VB = 2270 Pass
20.0.1 TestSW: [ADC_PA0] sense A do var VA = 2271 Pass
20.1 NZ3.1: Měření napětí: Zkrat? 28,00851 > 27,9 Pass
20.1.1 EL1.2: Ověření proudu na zátěži -> Current? 4,989843 4,7 5,3 Pass
20.1.2 TestSW: [ADC_PA0] sense A 2443 2436[VA] 2536[VA] Pass
20.1.3 TestSW: [ADC_PA1] sense B 2105 2005[VB] 2105[VB] Pass
20.1.4 TestSW: [ADC_PA2] sense C 2281 2210 2340 Pass
20.2 NZ3.1: Měření proudu: Kontrola odběru 0,03807751 < 0,06 Pass
20.2.1 EL1.2: Ověření proudu na zátěži -> Current? 4,989811 4,7 5,3 Pass
20.2.2 TestSW: [ADC_PA0] sense A 2099 2006[VA] 2106[VA] Pass
20.2.3 TestSW: [ADC_PA1] sense B 2434 2435[VB] 2535[VB] Fail

Measurements over time

Hover for exact values · drag to zoom · double-click to reset

Readings (3)
DateValueMinMax
2026-07-09 16:50 1.025 10
2026-07-09 16:51 1.018 10
2026-07-09 16:52 0.991 10