Testing Portal everyone (auth disabled)

Serial lookup

Search a serial number to see its full test history.

Serial 001342240

Tests6
Approved1
Failures5

Tests over time

Test history

DateMeasurement IDID recordArticleResult
2024-09-23 13:20 423 638626872036528716-2172 S0000608 Fail View
2024-09-23 13:20 424 638626872364193795-4561 S0000608 Fail View
2024-09-24 13:45 532 638627751023904250-3952 S0000608 Fail View
2024-09-24 13:51 533 638627755040010199-1325 S0000608 Fail View
2024-09-24 13:56 534 638627757561807252-1652 S0000608 Fail View
2024-09-24 13:58 535 638627758395962747-8532 S0000608 Pass View

Test 533

Result
Fail
Date
2024-09-24 13:51
Article
S0000608
ID record
638627755040010199-1325
ID production
47663
Temperature
26,83
Humidity
42,65
Test duration
8
Error ID
91
Error text
DMM: Kontrola hodnoty napětí (TP19/TP17,18)

Measurement lines

StepNameValueMinMaxResult
0.1 Uložení čísla výrobního příkazu 47663 Pass
0.2 Uložení ID obsluhy 0446 Pass
0.3 Uložení teploty okolí 26,83 Pass
0.4 Uložení vlhkosti okolí 42,65 Pass
0.5 Uložení Id testeru (uloženo na lokálním disku) Vez_Hokami_01-v01.01 Pass
0.6 Uložení id Artiklu (produktové číslo) S0000608 Pass
1.1 DMM: Kontrola hodnoty Odporu (TP2/TP3) 0,704782341 -1 1 Pass
1.2 DMM: Kontrola hodnoty Odporu (TP4/TP3) 5099,03363 5000 5200 Pass
1.3 DMM: Kontrola hodnoty Odporu (TP27/TP17,18) 10130,6029 9000 11000 Pass
2.1 DMM: Kontrola hodnoty Odporu (TP8/TP10) 1067,28291 1012 1120 Pass
4.1 NZ1: Odběr proudu ze zdroje (TP6/TP17,18) 0,00316208 0,0025 0,006 Pass
4.2 DMM: Kontrola hodnoty napětí (TP5/TP17,18) 11,9983764 11,9 12,1 Pass
4.3 DMM: Kontrola hodnoty napětí (TP19/TP17,18) 5,10186024 4,9 5,1 Fail

Measurements over time

No plottable values for this measurement.

Readings (1)
DateValueMinMax
2024-09-24 13:58