Serial lookup
Search a serial number to see its full test history.
Serial C01000316
Tests7
Approved2
Failures5
Tests over time
Test history
| Date | Measurement ID | ID record | Article | Result | |
|---|---|---|---|---|---|
| 2026-02-13 06:27 | 53290 | 639065608229155061-5713 | S0003590 | Fail | View |
| 2026-02-13 06:28 | 53291 | 639065608725437344-8919 | S0003590 | Fail | View |
| 2026-02-13 06:30 | 53292 | 639065609331979070-1988 | S0003590 | Fail | View |
| 2026-02-13 06:32 | 53293 | 639065610346265227-5770 | S0003590 | Fail | View |
| 2026-02-13 06:35 | 53294 | 639065611712242405-5768 | S0003590 | Fail | View |
| 2026-02-13 06:36 | 53295 | 639065613340098759-9705 | S0003590 | Pass | View |
| 2026-07-13 10:44 | 78004 | 639195361727035892-5881 | S0003590 | Pass | View |
Test 53290
- Result
- Fail
- Date
- 2026-02-13 06:27
- Article
- S0003590
- ID record
- 639065608229155061-5713
- ID production
- Temperature
- Humidity
- Test duration
- 41
- Error ID
- 116
- Error text
- Kontrola vypočítaného průměru z odporů: F1 (TP9/TP8)
Measurement lines
| Step | Name | Value | Min | Max | Result |
|---|---|---|---|---|---|
| 1.1.1 | DMM: Měření odporu: R1 (TP5/TP4) | 5624.82308 | 5320 | 5880 | Pass |
| 1.1.2 | DMM: Měření odporu: R2 (TP5/TP6) | 1001.84774 | 950 | 1050 | Pass |
| 1.2.1 | Kontrola vypočítaného průměru z odporů: F1 (TP9/TP8) | 2.068335 | 0 | 2 | Fail |
Measurements over time
Hover for exact values · drag to zoom · double-click to reset
Readings (1)
| Date | Value | Min | Max |
|---|---|---|---|
| 2026-07-13 10:44 | 1001.803 | 950 | 1050 |