Serial lookup
Search a serial number to see its full test history.
Serial C01000300
Tests8
Approved2
Failures6
Tests over time
Test history
| Date | Measurement ID | ID record | Article | Result | |
|---|---|---|---|---|---|
| 2026-02-12 13:25 | 53238 | 639064994953566550-1498 | S0003590 | Fail | View |
| 2026-02-12 13:27 | 53239 | 639064995606713757-7277 | S0003590 | Fail | View |
| 2026-02-12 13:28 | 53240 | 639064996410606860-9917 | S0003590 | Fail | View |
| 2026-02-12 13:29 | 53241 | 639064997123813827-5893 | S0003590 | Fail | View |
| 2026-02-12 13:30 | 53242 | 639064997860253872-5196 | S0003590 | Fail | View |
| 2026-02-13 05:15 | 53243 | 639065564959614794-7689 | S0003590 | Fail | View |
| 2026-02-13 05:17 | 53244 | 639065565669375126-3006 | S0003590 | Pass | View |
| 2026-07-13 09:35 | 77978 | 639195320415288506-7411 | S0003590 | Pass | View |
Test 53240
- Result
- Fail
- Date
- 2026-02-12 13:28
- Article
- S0003590
- ID record
- 639064996410606860-9917
- ID production
- Temperature
- Humidity
- Test duration
- 61
- Error ID
- 270
- Error text
- TestSW: commPLM test
Measurement lines
| Step | Name | Value | Min | Max | Result |
|---|---|---|---|---|---|
| 1.1.2 | DMM: Měření odporu: R2 (TP5/TP6) | 1002.569 | 950 | 1050 | Pass |
| 1.1.1 | DMM: Měření odporu: R1 (TP5/TP4) | 5619.72569 | 5320 | 5880 | Pass |
| 1.2.1 | Kontrola vypočítaného průměru z odporů: F1 (TP9/TP8) | 0.553692 | 0 | 2 | Pass |
| 1.2.2 | Kontrola vypočítaného průměru z odporů: F2 (TP10/TP11) | 0.624597 | 0 | 2 | Pass |
| 1.2.3 | Kontrola vypočítaného průměru z odporů: R3+R4 (TP10/TP8) | 420470.123714 | 400000 | 460000 | Pass |
| 2.2.1 | DMM: Měření napětí: +3V3 LDO OUTPUT (TP2/TP13) | 3.28913615 | 3.1 | 3.4 | Pass |
| 2.2.2 | DMM: Měření napětí: +3V3 Modem AVCC (TP2/TP15) | 3.28299572 | 3.1 | 3.4 | Pass |
| 2.2.3 | DMM: Měření napětí: +3V3 VDDA (TP2/TP24) | 3.28894297 | 3.1 | 3.4 | Pass |
| 2.2.4 | DMM: Měření napětí: +1V8 Audio (TP2/TP26) | 1.80332462 | 1.74 | 1.86 | Pass |
| 2.3.1 | DMM: Měření napětí: +12V ACDC měnič (TP2/TP12) | 11.9581195 | 11.7 | 12.3 | Pass |
| 3.2.1 | DMM: Měření frekvence: 1kHz (TP2/TP16) | 1000.0074 | 999.8 | 1000.2 | Pass |
| 3.3.1 | NZ3.2: Měření proudu: Kontrola odběru | 0.005013176 | < | 0.02 | Pass |
| 3.3.2 | NZ3.2: Měření proudu: Kontrola odběru | 0.005007281 | < | 0.2 | Pass |
| 3.4.1 | DMM: Měření odporu: (TP33/TP32) | 9.9E+37 | > | 10000000 | Pass |
| 3.4.2 | DMM: Měření odporu: (TP33/TP32) | 0.43176328 | < | 7 | Pass |
| 3.4.3 | DMM: Měření odporu: (TP35/TP34) | 9.9E+37 | > | 10000000 | Pass |
| 3.4.4 | DMM: Měření odporu: (TP35/TP34) | 2.31621358 | < | 7 | Pass |
| 3.4.5 | DMM: Měření odporu: (TP37/TP36) | 9.9E+37 | > | 10000000 | Pass |
| 3.4.6 | DMM: Měření odporu: (TP37/TP36) | 0.54177847 | < | 7 | Pass |
| 3.4.7 | DMM: Měření odporu: (TP39/TP40) | 9.9E+37 | > | 10000000 | Pass |
| 3.4.8 | DMM: Měření odporu: (TP39/TP40) | 115.04223 | 90 | 150 | Pass |
Measurements over time
Hover for exact values · drag to zoom · double-click to reset
Readings (1)
| Date | Value | Min | Max |
|---|---|---|---|
| 2026-07-13 09:35 | 1002.494 | 950 | 1050 |