Serial lookup
Search a serial number to see its full test history.
Serial C01000276
Tests8
Approved2
Failures6
Tests over time
Test history
| Date | Measurement ID | ID record | Article | Result | |
|---|---|---|---|---|---|
| 2026-02-12 08:36 | 53056 | 639064821565394709-1279 | S0003590 | Fail | View |
| 2026-02-12 08:37 | 53057 | 639064822228985652-6871 | S0003590 | Fail | View |
| 2026-02-12 08:38 | 53058 | 639064822846338758-6212 | S0003590 | Fail | View |
| 2026-02-12 08:40 | 53059 | 639064823633783046-6153 | S0003590 | Fail | View |
| 2026-02-12 08:41 | 53060 | 639064824277442140-7320 | S0003590 | Fail | View |
| 2026-02-12 08:42 | 53061 | 639064824924568743-2686 | S0003590 | Fail | View |
| 2026-02-12 08:43 | 53062 | 639064825585252718-1066 | S0003590 | Pass | View |
| 2026-07-14 05:44 | 78253 | 639196045764625748-7276 | S0003590 | Pass | View |
Test 53057
- Result
- Fail
- Date
- 2026-02-12 08:37
- Article
- S0003590
- ID record
- 639064822228985652-6871
- ID production
- Temperature
- Humidity
- Test duration
- 52
- Error ID
- 270
- Error text
- TestSW: commPLM test
Measurement lines
| Step | Name | Value | Min | Max | Result |
|---|---|---|---|---|---|
| 1.1.2 | DMM: Měření odporu: R2 (TP5/TP6) | 999.450669 | 950 | 1050 | Pass |
| 1.1.1 | DMM: Měření odporu: R1 (TP5/TP4) | 5633.10951 | 5320 | 5880 | Pass |
| 1.2.1 | Kontrola vypočítaného průměru z odporů: F1 (TP9/TP8) | 0.648198 | 0 | 2 | Pass |
| 1.2.2 | Kontrola vypočítaného průměru z odporů: F2 (TP10/TP11) | 0.596921 | 0 | 2 | Pass |
| 1.2.3 | Kontrola vypočítaného průměru z odporů: R3+R4 (TP10/TP8) | 420648.351429 | 400000 | 460000 | Pass |
| 2.2.1 | DMM: Měření napětí: +3V3 LDO OUTPUT (TP2/TP13) | 3.27835083 | 3.1 | 3.4 | Pass |
| 2.2.2 | DMM: Měření napětí: +3V3 Modem AVCC (TP2/TP15) | 3.27230294 | 3.1 | 3.4 | Pass |
| 2.2.3 | DMM: Měření napětí: +3V3 VDDA (TP2/TP24) | 3.27788198 | 3.1 | 3.4 | Pass |
| 2.2.4 | DMM: Měření napětí: +1V8 Audio (TP2/TP26) | 1.79874886 | 1.74 | 1.86 | Pass |
| 2.3.1 | DMM: Měření napětí: +12V ACDC měnič (TP2/TP12) | 11.9572123 | 11.7 | 12.3 | Pass |
| 3.2.1 | DMM: Měření frekvence: 1kHz (TP2/TP16) | 1000.00825 | 999.8 | 1000.2 | Pass |
| 3.3.1 | NZ3.2: Měření proudu: Kontrola odběru | 0.005045636 | < | 0.02 | Pass |
| 3.3.2 | NZ3.2: Měření proudu: Kontrola odběru | 0.005030899 | < | 0.2 | Pass |
| 3.4.1 | DMM: Měření odporu: (TP33/TP32) | 9.9E+37 | > | 10000000 | Pass |
| 3.4.2 | DMM: Měření odporu: (TP33/TP32) | 0.382951436 | < | 7 | Pass |
| 3.4.3 | DMM: Měření odporu: (TP35/TP34) | 9.9E+37 | > | 10000000 | Pass |
| 3.4.4 | DMM: Měření odporu: (TP35/TP34) | 2.60735953 | < | 7 | Pass |
| 3.4.5 | DMM: Měření odporu: (TP37/TP36) | 9.9E+37 | > | 10000000 | Pass |
| 3.4.6 | DMM: Měření odporu: (TP37/TP36) | 0.498301652 | < | 7 | Pass |
| 3.4.7 | DMM: Měření odporu: (TP39/TP40) | 9.9E+37 | > | 10000000 | Pass |
| 3.4.8 | DMM: Měření odporu: (TP39/TP40) | 115.090005 | 90 | 150 | Pass |
Measurements over time
Hover for exact values · drag to zoom · double-click to reset
Readings (1)
| Date | Value | Min | Max |
|---|---|---|---|
| 2026-07-14 05:44 | 999.433 | 950 | 1050 |