Serial lookup
Search a serial number to see its full test history.
Serial 001791578
Tests22
Approved0
Failures22
Tests over time
Test history
| Date | Measurement ID | ID record | Article | Result | |
|---|---|---|---|---|---|
| 2024-09-04 14:12 | 114 | 638610486888877058-9531 | S0001055 | Fail | View |
| 2024-09-04 14:30 | 115 | 638610497401260218-2807 | S0001055 | Fail | View |
| 2024-09-04 14:41 | 116 | 638610504469083172-5380 | S0001055 | Fail | View |
| 2024-09-23 08:44 | 523 | 638626706164341626-3965 | S0001055 | Fail | View |
| 2024-09-24 14:56 | 556 | 638627793110007926-2864 | S0001055 | Fail | View |
| 2024-12-05 15:03 | 5421 | 638690041958178769-5070 | S0001055 | Fail | View |
| 2024-12-05 15:27 | 5422 | 638690056125590398-2916 | S0001055 | Fail | View |
| 2025-09-05 11:00 | 25771 | 638926595543560649-9260 | S0001055 | Fail | View |
| 2025-11-06 17:36 | 40593 | 638980437269818807-7284 | S0001055 | Fail | View |
| 2026-07-09 15:09 | 77758 | 639192065613260614-6430 | S0001055 | Fail | View |
| 2026-07-09 15:12 | 77759 | 639192067213211955-6883 | S0001055 | Fail | View |
| 2026-07-09 15:27 | 77772 | 639192076194697877-7528 | S0001055 | Fail | View |
| 2026-07-09 15:28 | 77773 | 639192076878611735-9235 | S0001055 | Fail | View |
| 2026-08-11 04:59 | 81278 | 639220211645563662-9540 | S0001055 | Fail | View |
| 2026-08-11 05:00 | 81279 | 639220211860886980-3595 | S0001055 | Fail | View |
| 2026-08-11 05:01 | 81280 | 639220212595640544-4184 | S0001055 | Fail | View |
| 2026-09-23 05:08 | 86082 | 639257369006585667-9621 | S0001055 | Fail | View |
| 2026-09-23 05:08 | 86083 | 639257369255668365-5345 | S0001055 | Fail | View |
| 2026-09-23 05:09 | 86084 | 639257369585509164-2435 | S0001055 | Fail | View |
| 2026-09-23 05:12 | 86085 | 639257371148163467-5262 | S0001055 | Fail | View |
| 2026-09-23 05:24 | 86092 | 639257378683577295-1001 | S0001055 | Fail | View |
| 2026-09-23 05:51 | 86107 | 639257394682227791-2483 | S0001055 | Fail | View |
Test 523
- Result
- Fail
- Date
- 2024-09-23 08:44
- Article
- S0001055
- ID record
- 638626706164341626-3965
- ID production
- 49267
- Temperature
- 25,81
- Humidity
- 36,79
- Test duration
- 55
- Error ID
- 385
- Error text
- TestSW: [ADC_PA2] sense C
Measurement lines
| Step | Name | Value | Min | Max | Result |
|---|---|---|---|---|---|
| 0.3 | Uložení teploty okolí | 25,81 | Pass | ||
| 0.4 | Uložení vlhkosti okolí | 36,79 | Pass | ||
| 0.5 | Uložení Id testeru (uloženo na lokálním disku) | Vez_Hokami_01-v01.01 | Pass | ||
| 0.6 | Uložení id Artiklu (produktové číslo) | S0001055 | Pass | ||
| 1.1 | DMM: Kontrola hodnoty Odporu (TP6/TP4) | 0,565070012 | < | 10 | Pass |
| 1.2 | DMM: Kontrola hodnoty Odporu (TP6/TP5) | 997,839347 | 800 | 1200 | Pass |
| 3.1 | NZ3.1: Měření napětí: Zkrat? | 28,00851 | > | 27,9 | Pass |
| 3.2 | NZ3.1: Měření proudu: Kontrola odběru | 0,0007822168 | < | 0,005 | Pass |
| 3.3 | R11.12: Zapnutí (TP42/TP43) | Pass | |||
| 3.4 | NZ3.1: Měření napětí: Zkrat? | 28,00851 | > | 27,9 | Pass |
| 3.5 | NZ3.1: Měření proudu: Kontrola odběru | 0,02436586 | < | 0,04 | Pass |
| 4.1 | DMM: Měření napětí: +BATT (TP49/TP44) | 27,9747942 | 27,9 | 28,1 | Pass |
| 4.2 | DMM: Měření napětí: +BATT (TP49/TP34) | 27,9984109 | 27,9 | 28,1 | Pass |
| 4.3 | DMM: Měření napětí: +12V (TP49/TP46) | 11,876816 | 11 | 12,2 | Pass |
| 4.4 | DMM: Měření napětí: +5V (TP49/TP7) | 4,99732858 | 4,9 | 5,1 | Pass |
| 4.5 | DMM: Měření napětí: +3V3 (TP49/TP16) | 3,29662265 | 3,2 | 3,4 | Pass |
| 4.6 | DMM: Měření napětí: VDDA +3V3 (TP49/TP2) | 3,29663287 | 3,2 | 3,4 | Pass |
| 4.7 | DMM: Měření napětí: (TP49/TP8) | 4,67730791 | 4,57 | 4,77 | Pass |
| 4.8 | DMM: Měření napětí: (TP49/TP9) | 4,67405401 | 4,57 | 4,77 | Pass |
| 4.9 | DMM: Měření napětí: (TP49/TP10) | 4,6757804 | 4,57 | 4,77 | Pass |
| 5.1 | DMM: Měření napětí: (TP49/TP46) | 0,534970431 | < | 1 | Pass |
| 5.2 | DMM: Měření napětí: (TP49/TP46) | 11,7969715 | > | 11,5 | Pass |
| 6.1 | R9.12: Vypnutí (TP49/TP28) | Pass | |||
| 7.1 | NZ3: Měření napětí: Zkrat? | 28,00651 | > | 27,9 | Pass |
| 7.2 | NZ3: Měření proudu: Kontrola odběru | 0,02538252 | < | 0,06 | Pass |
| 7.3 | R0.6: Zapnutí Ext. Programátoru | Pass | |||
| 8.1 | TestSw: Ověření komunikace | [TYP:AA NAME:eDrive NAME2:TestSW HW:Kolecko v4 SW: | Pass | ||
| 9.1 | TestSW: [CHG_SIG (PC14)] = log1? | 16384 | 16384 | 16384 | Pass |
| 9.2 | EL1.1: Ověření proudu na zátěži -> Current? | 2,126704 | 1,6 | 2,8 | Pass |
| 9.3 | DMM: Měření napětí: Vstup U14 (TP39/TP32) | 29,6551792 | 29 | 30,1 | Pass |
| 9.4 | DMM: Měření napětí: Vstup U14 (TP39/TP33) | 11,2240826 | 10,8 | 11,5 | Pass |
| 9.5 | DMM: Měření napětí: Vstup U14 (TP39/TP40) | 1,60665929 | 1,5 | 1,8 | Pass |
| 10.1 | NZ3.1: Měření napětí: Zkrat? | 28,00851 | > | 27,9 | Pass |
| 10.2 | NZ3.1: Měření proudu: Kontrola odběru | 0,02518508 | < | 0,06 | Pass |
| 10.3 | TestSW: [ADC_PA03] | 3844 | 3667 | 3937 | Pass |
| 12.1 | TestSW: [PA15] - napájení sense ABC | Pass | |||
| 12.2 | TestSW: [HALL_A (PB4)] = log0? | 0 | 0 | 0 | Pass |
| 12.3 | TestSW: [HALL_A (PB4)] = log1? | 16 | 16 | 16 | Pass |
| 12.4 | TestSW: [HALL_B (PB5)] = log0? | 0 | 0 | 0 | Pass |
| 12.5 | TestSW: [HALL_B (PB5)] = log1? | 32 | 32 | 32 | Pass |
| 12.6 | TestSW: [HALL_C (PB0)] = log0? | 0 | 0 | 0 | Pass |
| 12.7 | TestSW: [HALL_C (PB0)] = log1? | 1 | 1 | 1 | Pass |
| 13.1 | TestSW: [CON_ID (PC13)] = log1? | 8192 | 8192 | 8192 | Pass |
| 13.10 | TestSW: [BTN_FFWD][ADC_PA6]? | 4086 | 4000 | 4096 | Pass |
| 13.11 | TestSW: [BTN_FFWD][ADC_PA6]? | 2028 | 1900 | 2100 | Pass |
| 13.12 | TestSW: [BTN_STOP][ADC_PA5]? | 4085 | 4000 | 4096 | Pass |
| 13.13 | TestSW: [BTN_STOP][ADC_PA5]? | 2026 | 1900 | 2100 | Pass |
| 13.2 | TestSW: [CON_ID (PC13)] = log0? | 0 | 0 | 0 | Pass |
| 13.3 | TestSW: [BTN_DRV][PA11] na log1 | Pass | |||
| 13.4 | TestSW: [BTN_FWD][ADC_PB1]? | 4085 | 4000 | 4096 | Pass |
| 13.5 | TestSW: [BTN_FWD][ADC_PB1]? | 2015 | 1900 | 2100 | Pass |
| 13.6 | TestSW: [BTN_REV][ADC_PA4]? | 4085 | 4000 | 4096 | Pass |
| 13.7 | TestSW: [BTN_REV][ADC_PA4]? | 2027 | 1900 | 2100 | Pass |
| 13.8 | TestSW: [BTN_ULCK][ADC_PA7]? | 4085 | 4000 | 4096 | Pass |
| 13.9 | TestSW: [BTN_ULCK][ADC_PA7]? | 2026 | 1900 | 2100 | Pass |
| 14.1 | TestSW: [LED1][PB2] na log1 | Pass | |||
| 14.10 | DMM: Měření napětí: LED3 (TP49/TP14) | 3,29238714 | > | 3 | Pass |
| 14.11 | TestSW: [LED3][PB11] na log0 | Pass | |||
| 14.12 | DMM: Měření napětí: LED3 (TP49/TP14) | 0,00352325997 | < | 0,1 | Pass |
| 14.13 | TestSW: [LED4][PB12] na log1 | Pass | |||
| 14.14 | DMM: Měření napětí: LED4 (TP49/TP12) | 3,29366758 | > | 3 | Pass |
| 14.15 | TestSW: [LED4][PB12] na log0 | Pass | |||
| 14.16 | DMM: Měření napětí: LED4 (TP49/TP12) | 0,00352212044 | < | 0,1 | Pass |
| 14.2 | DMM: Měření napětí: LED1 (TP49/TP13) | 3,29222796 | > | 3 | Pass |
| 14.3 | TestSW: [LED1][PB2] na log0 | Pass | |||
| 14.4 | DMM: Měření napětí: LED1 (TP49/TP13) | 0,00362161012 | < | 0,1 | Pass |
| 14.5 | TestSW: [LED2][PB10] na log1 | Pass | |||
| 14.6 | DMM: Měření napětí: LED1 (TP49/TP11) | 3,29236886 | > | 3 | Pass |
| 14.7 | TestSW: [LED2][PB10] na log0 | Pass | |||
| 14.8 | DMM: Měření napětí: LED1 (TP49/TP11) | 0,00352806077 | < | 0,1 | Pass |
| 14.9 | TestSW: [LED3][PB11] na log1 | Pass | |||
| 15.1 | TestSW: ntc | 63 | 49 | 90 | Pass |
| 16.1 | DMM: Měření frekvence (TP49/TP55) | 19995,0274 | 19600 | 20400 | Pass |
| 16.2 | DMM: Měření frekvence (TP49/TP56) | 19995,0236 | 19600 | 20400 | Pass |
| 16.3 | DMM: Měření napětí (TP49/TP52) | 14,0130048 | 13,3 | 14,7 | Pass |
| 17.1 | DMM: Měření frekvence (TP49/TP61) | 19995,0198 | 19600 | 20400 | Pass |
| 17.2 | DMM: Měření frekvence (TP49/TP62) | 19995,0232 | 19600 | 20400 | Pass |
| 17.3 | DMM: Měření napětí (TP49/TP58) | 14,0107711 | 13,3 | 14,7 | Pass |
| 18.1 | DMM: Měření frekvence (TP49/TP67) | 19995,0194 | 19600 | 20400 | Pass |
| 18.2 | DMM: Měření frekvence (TP49/TP68) | 19995,0213 | 19600 | 20400 | Pass |
| 18.3 | DMM: Měření napětí (TP49/TP58) | 14,0098446 | 13,3 | 14,7 | Pass |
| 19.1 | DMM: Měření napětí: +5V (TP49/TP7) | 0,0114819469 | < | 0,5 | Pass |
| 20.0.1 | TestSW: [ADC_PA0] sense A do var | VA = 2269 | Pass | ||
| 20.0.2 | TestSW: [ADC_PA1] sense B do var | VB = 2266 | Pass | ||
| 20.0.3 | TestSW: [ADC_PA2] sense C do var | VC = 2272 | Pass | ||
| 20.0.5 | Analysis: VA | VA[2269] | 2210 | 2340 | Pass |
| 20.0.6 | Analysis: VB | VB[2266] | 2210 | 2340 | Pass |
| 20.0.7 | Analysis: VC | VC[2272] | 2210 | 2340 | Pass |
| 20.1 | NZ3.1: Měření napětí: Zkrat? | 28,00851 | > | 27,9 | Pass |
| 20.1.1 | EL1.2: Ověření proudu na zátěži -> Current? | 4,989632 | 4,7 | 5,3 | Pass |
| 20.1.2 | TestSW: [ADC_PA0] sense A | 2442 | 2434[VA] | 2534[VA] | Pass |
| 20.1.3 | TestSW: [ADC_PA1] sense B | 2097 | 2001[VB] | 2101[VB] | Pass |
| 20.1.4 | TestSW: [ADC_PA2] sense C | 2273 | 2210 | 2340 | Pass |
| 20.2 | NZ3.1: Měření proudu: Kontrola odběru | 0,03817771 | < | 0,06 | Pass |
| 20.2.1 | EL1.2: Ověření proudu na zátěži -> Current? | 4,9897 | 4,7 | 5,3 | Pass |
| 20.2.2 | TestSW: [ADC_PA0] sense A | 2095 | 2004[VA] | 2104[VA] | Pass |
| 20.2.3 | TestSW: [ADC_PA1] sense B | 2433 | 2431[VB] | 2531[VB] | Pass |
| 20.2.4 | TestSW: [ADC_PA2] sense C | 2273 | 2210 | 2340 | Pass |
| 20.3.1 | EL1.2: Ověření proudu na zátěži -> Current? | 4,989561 | 4,7 | 5,3 | Pass |
| 20.3.2 | TestSW: [ADC_PA0] sense A | 2442 | 2434[VA] | 2534[VA] | Pass |
| 20.3.3 | TestSW: [ADC_PA1] sense B | 2268 | 2210 | 2340 | Pass |
| 20.3.4 | TestSW: [ADC_PA2] sense C | 2109 | 2007[VC] | 2107[VC] | Fail |
Measurements over time
Hover for exact values · drag to zoom · double-click to reset
Readings (13)
| Date | Value | Min | Max |
|---|---|---|---|
| 2026-07-09 15:09 | 1 | — | 10 |
| 2026-07-09 15:12 | 0.968 | — | 10 |
| 2026-07-09 15:27 | 0.955 | — | 10 |
| 2026-07-09 15:28 | 0.945 | — | 10 |
| 2026-08-11 04:59 | 0.791 | — | 10 |
| 2026-08-11 05:00 | 0.765 | — | 10 |
| 2026-08-11 05:01 | 0.758 | — | 10 |
| 2026-09-23 05:08 | 0.776 | — | 10 |
| 2026-09-23 05:08 | 0.776 | — | 10 |
| 2026-09-23 05:09 | 0.766 | — | 10 |
| 2026-09-23 05:12 | 0.76 | — | 10 |
| 2026-09-23 05:24 | 0.954 | — | 10 |
| 2026-09-23 05:51 | 0.954 | — | 10 |