Serial 001791577

Tests18
Approved1
Failures17

Tests over time

Test history

DateMeasurement IDID recordArticleResult
2024-09-04 14:06 112 638610483354289866-8151 S0001055 Fail View
2024-09-04 14:28 113 638610496647410178-6006 S0001055 Fail View
2024-09-23 08:40 522 638626703861855352-9107 S0001055 Fail View
2024-12-05 15:09 5419 638690045347578008-1434 S0001055 Fail View
2024-12-05 15:23 5420 638690053423493414-7160 S0001055 Fail View
2025-09-05 11:31 25770 638926614658429713-5924 S0001055 Fail View
2025-11-06 17:37 40592 638980438088384798-4910 S0001055 Fail View
2026-07-09 15:22 77768 639192073284021356-6117 S0001055 Fail View
2026-07-09 15:23 77769 639192074081305022-8129 S0001055 Fail View
2026-07-09 15:25 77770 639192074775211055-8962 S0001055 Fail View
2026-07-09 15:38 77781 639192082876397769-8704 S0001055 Fail View
2026-07-09 15:40 77782 639192083938420667-9924 S0001055 Fail View
2026-08-11 05:02 81281 639220213635683812-4805 S0001055 Fail View
2026-08-11 05:03 81282 639220213899747345-1973 S0001055 Fail View
2026-09-23 05:17 86089 639257374405244824-8905 S0001055 Fail View
2026-09-23 05:23 86090 639257377966590201-2611 S0001055 Fail View
2026-09-23 05:27 86094 639257379852218894-8357 S0001055 Fail View
2026-09-23 05:28 86095 639257380400504176-7403 S0001055 Pass View

Test 522

Result
Fail
Date
2024-09-23 08:40
Article
S0001055
ID record
638626703861855352-9107
ID production
49267
Temperature
25,71
Humidity
36,84
Test duration
55
Error ID
371
Error text
TestSW: [ADC_PA1] sense B

Measurement lines

StepNameValueMinMaxResult
0.3 Uložení teploty okolí 25,71 Pass
0.4 Uložení vlhkosti okolí 36,84 Pass
0.5 Uložení Id testeru (uloženo na lokálním disku) Vez_Hokami_01-v01.01 Pass
0.6 Uložení id Artiklu (produktové číslo) S0001055 Pass
1.1 DMM: Kontrola hodnoty Odporu (TP6/TP4) 0,550729183 < 10 Pass
1.2 DMM: Kontrola hodnoty Odporu (TP6/TP5) 996,398929 800 1200 Pass
3.1 NZ3.1: Měření napětí: Zkrat? 28,00651 > 27,9 Pass
3.2 NZ3.1: Měření proudu: Kontrola odběru 0,0008411763 < 0,005 Pass
3.3 R11.12: Zapnutí (TP42/TP43) Pass
3.4 NZ3.1: Měření napětí: Zkrat? 28,00651 > 27,9 Pass
3.5 NZ3.1: Měření proudu: Kontrola odběru 0,02412714 < 0,04 Pass
4.1 DMM: Měření napětí: +BATT (TP49/TP44) 27,9750373 27,9 28,1 Pass
4.2 DMM: Měření napětí: +BATT (TP49/TP34) 27,9988429 27,9 28,1 Pass
4.3 DMM: Měření napětí: +12V (TP49/TP46) 11,9060041 11 12,2 Pass
4.4 DMM: Měření napětí: +5V (TP49/TP7) 4,99347017 4,9 5,1 Pass
4.5 DMM: Měření napětí: +3V3 (TP49/TP16) 3,29437379 3,2 3,4 Pass
4.6 DMM: Měření napětí: VDDA +3V3 (TP49/TP2) 3,29437796 3,2 3,4 Pass
4.7 DMM: Měření napětí: (TP49/TP8) 4,67397592 4,57 4,77 Pass
4.8 DMM: Měření napětí: (TP49/TP9) 4,67171025 4,57 4,77 Pass
4.9 DMM: Měření napětí: (TP49/TP10) 4,67185886 4,57 4,77 Pass
5.1 DMM: Měření napětí: (TP49/TP46) 0,526734772 < 1 Pass
5.2 DMM: Měření napětí: (TP49/TP46) 11,822514 > 11,5 Pass
6.1 R9.12: Vypnutí (TP49/TP28) Pass
7.1 NZ3: Měření napětí: Zkrat? 28,00651 > 27,9 Pass
7.2 NZ3: Měření proudu: Kontrola odběru 0,02518508 < 0,06 Pass
7.3 R0.6: Zapnutí Ext. Programátoru Pass
8.1 TestSw: Ověření komunikace [TYP:AA NAME:eDrive NAME2:TestSW HW:Kolecko v4 SW: Pass
9.1 TestSW: [CHG_SIG (PC14)] = log1? 16384 16384 16384 Pass
9.2 EL1.1: Ověření proudu na zátěži -> Current? 2,132654 1,6 2,8 Pass
9.3 DMM: Měření napětí: Vstup U14 (TP39/TP32) 29,6555778 29 30,1 Pass
9.4 DMM: Měření napětí: Vstup U14 (TP39/TP33) 11,2381335 10,8 11,5 Pass
9.5 DMM: Měření napětí: Vstup U14 (TP39/TP40) 1,59033178 1,5 1,8 Pass
10.1 NZ3.1: Měření napětí: Zkrat? 28,00851 > 27,9 Pass
10.2 NZ3.1: Měření proudu: Kontrola odběru 0,02529998 < 0,06 Pass
10.3 TestSW: [ADC_PA03] 3858 3667 3937 Pass
12.1 TestSW: [PA15] - napájení sense ABC Pass
12.2 TestSW: [HALL_A (PB4)] = log0? 0 0 0 Pass
12.3 TestSW: [HALL_A (PB4)] = log1? 16 16 16 Pass
12.4 TestSW: [HALL_B (PB5)] = log0? 0 0 0 Pass
12.5 TestSW: [HALL_B (PB5)] = log1? 32 32 32 Pass
12.6 TestSW: [HALL_C (PB0)] = log0? 0 0 0 Pass
12.7 TestSW: [HALL_C (PB0)] = log1? 1 1 1 Pass
13.1 TestSW: [CON_ID (PC13)] = log1? 8192 8192 8192 Pass
13.10 TestSW: [BTN_FFWD][ADC_PA6]? 4085 4000 4096 Pass
13.11 TestSW: [BTN_FFWD][ADC_PA6]? 2027 1900 2100 Pass
13.12 TestSW: [BTN_STOP][ADC_PA5]? 4085 4000 4096 Pass
13.13 TestSW: [BTN_STOP][ADC_PA5]? 2026 1900 2100 Pass
13.2 TestSW: [CON_ID (PC13)] = log0? 0 0 0 Pass
13.3 TestSW: [BTN_DRV][PA11] na log1 Pass
13.4 TestSW: [BTN_FWD][ADC_PB1]? 4084 4000 4096 Pass
13.5 TestSW: [BTN_FWD][ADC_PB1]? 2013 1900 2100 Pass
13.6 TestSW: [BTN_REV][ADC_PA4]? 4085 4000 4096 Pass
13.7 TestSW: [BTN_REV][ADC_PA4]? 2025 1900 2100 Pass
13.8 TestSW: [BTN_ULCK][ADC_PA7]? 4085 4000 4096 Pass
13.9 TestSW: [BTN_ULCK][ADC_PA7]? 2025 1900 2100 Pass
14.1 TestSW: [LED1][PB2] na log1 Pass
14.10 DMM: Měření napětí: LED3 (TP49/TP14) 3,29002562 > 3 Pass
14.11 TestSW: [LED3][PB11] na log0 Pass
14.12 DMM: Měření napětí: LED3 (TP49/TP14) 0,00348378474 < 0,1 Pass
14.13 TestSW: [LED4][PB12] na log1 Pass
14.14 DMM: Měření napětí: LED4 (TP49/TP12) 3,29129463 > 3 Pass
14.15 TestSW: [LED4][PB12] na log0 Pass
14.16 DMM: Měření napětí: LED4 (TP49/TP12) 0,00345973381 < 0,1 Pass
14.2 DMM: Měření napětí: LED1 (TP49/TP13) 3,2898299 > 3 Pass
14.3 TestSW: [LED1][PB2] na log0 Pass
14.4 DMM: Měření napětí: LED1 (TP49/TP13) 0,00371739122 < 0,1 Pass
14.5 TestSW: [LED2][PB10] na log1 Pass
14.6 DMM: Měření napětí: LED1 (TP49/TP11) 3,29000824 > 3 Pass
14.7 TestSW: [LED2][PB10] na log0 Pass
14.8 DMM: Měření napětí: LED1 (TP49/TP11) 0,00349375556 < 0,1 Pass
14.9 TestSW: [LED3][PB11] na log1 Pass
15.1 TestSW: ntc 61 49 90 Pass
16.1 DMM: Měření frekvence (TP49/TP55) 19995,0439 19600 20400 Pass
16.2 DMM: Měření frekvence (TP49/TP56) 19995,0443 19600 20400 Pass
16.3 DMM: Měření napětí (TP49/TP52) 14,0066776 13,3 14,7 Pass
17.1 DMM: Měření frekvence (TP49/TP61) 19995,0368 19600 20400 Pass
17.2 DMM: Měření frekvence (TP49/TP62) 19995,042 19600 20400 Pass
17.3 DMM: Měření napětí (TP49/TP58) 14,0071088 13,3 14,7 Pass
18.1 DMM: Měření frekvence (TP49/TP67) 19995,0383 19600 20400 Pass
18.2 DMM: Měření frekvence (TP49/TP68) 19995,042 19600 20400 Pass
18.3 DMM: Měření napětí (TP49/TP58) 14,0132725 13,3 14,7 Pass
19.1 DMM: Měření napětí: +5V (TP49/TP7) 0,0106387991 < 0,5 Pass
20.0.3 TestSW: [ADC_PA2] sense C do var VC = 2272 Pass
20.0.7 Analysis: VC VC[2272] 2210 2340 Pass
20.0.6 Analysis: VB VB[2268] 2210 2340 Pass
20.0.5 Analysis: VA VA[2269] 2210 2340 Pass
20.0.2 TestSW: [ADC_PA1] sense B do var VB = 2268 Pass
20.0.1 TestSW: [ADC_PA0] sense A do var VA = 2269 Pass
20.1 NZ3.1: Měření napětí: Zkrat? 28,00851 > 27,9 Pass
20.1.1 EL1.2: Ověření proudu na zátěži -> Current? 4,98965 4,7 5,3 Pass
20.1.2 TestSW: [ADC_PA0] sense A 2436 2434[VA] 2534[VA] Pass
20.1.3 TestSW: [ADC_PA1] sense B 2103 2003[VB] 2103[VB] Pass
20.1.4 TestSW: [ADC_PA2] sense C 2273 2210 2340 Pass
20.2 NZ3.1: Měření proudu: Kontrola odběru 0,03779756 < 0,06 Pass
20.2.1 EL1.2: Ověření proudu na zátěži -> Current? 4,989733 4,7 5,3 Pass
20.2.2 TestSW: [ADC_PA0] sense A 2101 2004[VA] 2104[VA] Pass
20.2.3 TestSW: [ADC_PA1] sense B 2432 2433[VB] 2533[VB] Fail

Measurements over time

Hover for exact values · drag to zoom · double-click to reset

Readings (11)
DateValueMinMax
2026-07-09 15:22 0.985 10
2026-07-09 15:23 0.96 10
2026-07-09 15:25 0.945 10
2026-07-09 15:38 0.977 10
2026-07-09 15:40 0.945 10
2026-08-11 05:02 0.974 10
2026-08-11 05:03 0.832 10
2026-09-23 05:17 1.19 10
2026-09-23 05:23 1.088 10
2026-09-23 05:27 0.905 10
2026-09-23 05:28 0.993 10