Testing Portal everyone (auth disabled)

Serial lookup

Search a serial number to see its full test history.

Serial C00000064

Tests5
Approved0
Failures5

Tests over time

Test history

DateMeasurement IDID recordArticleResult
2026-02-10 10:05 52068 639063146990285680-3604 S0003590 Fail View
2026-02-10 11:08 52092 639063185038919698-9530 S0003590 Fail View
2026-02-10 11:16 52098 639063190114689779-1598 S0003590 Fail View
2026-02-10 11:24 52103 639063194781122672-6535 S0003590 Fail View
2026-02-10 11:25 52104 639063195155333159-8336 S0003590 Fail View

Test 52068

Result
Fail
Date
2026-02-10 10:05
Article
S0003590
ID record
639063146990285680-3604
ID production
Temperature
Humidity
Test duration
31
Error ID
Error text

Measurement lines

StepNameValueMinMaxResult
1.1.1 DMM: Měření odporu: R1 (TP5/TP4) 1.41620555 < 10 Pass
1.1.2 DMM: Měření odporu: R2 (TP5/TP6) 4702.76924 4600 4800 Pass
1.2.1 Kontrola vypočítaného průměru z odporů: F1 (TP9/TP8) 0.482682 0 2 Pass
1.2.2 Kontrola vypočítaného průměru z odporů: F2 (TP10/TP11) 0.5754 0 2 Pass
1.2.3 Kontrola vypočítaného průměru z odporů: R3+R4 (TP10/TP8) 421004.574 400000 460000 Pass
2.2.1 DMM: Měření napětí: +3V3 LDO OUTPUT (TP2/TP13) 3.28592599 3.1 3.4 Pass
2.2.2 DMM: Měření napětí: +3V3 Modem AVCC (TP2/TP15) 3.28040447 3.1 3.4 Pass
2.2.3 DMM: Měření napětí: +3V3 VDDA (TP2/TP24) 3.2855032 3.1 3.4 Pass
2.2.4 DMM: Měření napětí: +1V8 Audio (TP2/TP26) 1.80044762 1.74 1.86 Pass
2.3.1 DMM: Měření napětí: +12V ACDC měnič (TP2/TP12) 11.9578217 11.7 12.3 Pass

Measurements over time

Hover for exact values · drag to zoom · double-click to reset

Readings (5)
DateValueMinMax
2026-02-10 10:05 4702.769 4600 4800
2026-02-10 11:08 4702.76 4600 4800
2026-02-10 11:16 4702.665 4600 4800
2026-02-10 11:24 4720.633 4600 4800
2026-02-10 11:25 4720.642 4600 4800