Testing Portal everyone (auth disabled)

Serial lookup

Search a serial number to see its full test history.

Serial 001676314

Tests7
Approved0
Failures7

Tests over time

Test history

DateMeasurement IDID recordArticleResult
2025-09-05 10:51 25804 638926590918730711-6119 S0001055 Fail View
2025-11-06 17:03 40605 638980417818362543-2431 S0001055 Fail View
2026-02-05 07:28 51262 639058732921280653-3224 S0001055 Fail View
2026-02-05 07:30 51263 639058733557148916-4262 S0001055 Fail View
2026-02-05 07:31 51264 639058734223318284-9541 S0001055 Fail View
2026-07-09 15:55 77786 639192092561627117-6482 S0001055 Fail View
2026-07-09 15:56 77787 639192093295679973-3558 S0001055 Fail View

Test 51262

Result
Fail
Date
2026-02-05 07:28
Article
S0001055
ID record
639058732921280653-3224
ID production
49348
Temperature
25.86
Humidity
27.89
Test duration
43
Error ID
287
Error text
TestSW: ntc

Measurement lines

StepNameValueMinMaxResult
1.1 DMM: Kontrola hodnoty Odporu (TP6/TP4) 0.624557094 < 10 Pass
1.2 DMM: Kontrola hodnoty Odporu (TP6/TP5) 1005.10413 800 1200 Pass
3.1 NZ3.1: Měření napětí: Zkrat? 28.00651 > 27.9 Pass
3.2 NZ3.1: Měření proudu: Kontrola odběru 0.0009561034 < 0.005 Pass
3.3 R11.12: Zapnutí (TP42/TP43) Pass
3.4 NZ3.1: Měření napětí: Zkrat? 28.00651 > 27.9 Pass
3.5 NZ3.1: Měření proudu: Kontrola odběru 0.02424209 < 0.04 Pass
4.1 DMM: Měření napětí: +BATT (TP49/TP44) 27.9607221 27.9 28.1 Pass
4.2 DMM: Měření napětí: +BATT (TP49/TP34) 27.9966688 27.9 28.1 Pass
4.3 DMM: Měření napětí: +12V (TP49/TP46) 11.839978 11 12.2 Pass
4.4 DMM: Měření napětí: +5V (TP49/TP7) 4.98034345 4.9 5.1 Pass
4.5 DMM: Měření napětí: +3V3 (TP49/TP16) 3.31282629 3.2 3.4 Pass
4.6 DMM: Měření napětí: VDDA +3V3 (TP49/TP2) 3.31282132 3.2 3.4 Pass
4.7 DMM: Měření napětí: (TP49/TP8) 4.66510236 4.57 4.77 Pass
4.8 DMM: Měření napětí: (TP49/TP9) 4.65920143 4.57 4.77 Pass
4.9 DMM: Měření napětí: (TP49/TP10) 4.65949022 4.57 4.77 Pass
5.1 DMM: Měření napětí: (TP49/TP46) 0.5440796 < 1 Pass
5.2 DMM: Měření napětí: (TP49/TP46) 11.7512568 > 11.5 Pass
6.1 R9.12: Vypnutí (TP49/TP28) Pass
7.1 NZ3: Měření napětí: Zkrat? 28.00651 > 27.9 Pass
7.2 NZ3: Měření proudu: Kontrola odběru 0.02542083 < 0.06 Pass
7.3 R0.6: Zapnutí Ext. Programátoru Pass
8.1 TestSw: Ověření komunikace [TYP:AA NAME:eDrive NAME2:TestSW HW:Kolecko v4 SW: Pass
9.1 TestSW: [CHG_SIG (PC14)] = log1? 16384 16384 16384 Pass
9.2 EL1.1: Ověření proudu na zátěži -> Current? 1.947132 1.6 2.8 Pass
9.3 DMM: Měření napětí: Vstup U14 (TP39/TP32) 29.5938098 29 30.1 Pass
9.4 DMM: Měření napětí: Vstup U14 (TP39/TP33) 11.2315206 10.8 11.5 Pass
9.5 DMM: Měření napětí: Vstup U14 (TP39/TP40) 1.60893572 1.5 1.8 Pass
10.1 NZ3.1: Měření napětí: Zkrat? 28.00651 > 27.9 Pass
10.2 NZ3.1: Měření proudu: Kontrola odběru 0.02538841 < 0.06 Pass
10.3 TestSW: [ADC_PA03] 3823 3667 3937 Pass
12.1 TestSW: [PA15] - napájení sense ABC Pass
12.2 TestSW: [HALL_A (PB4)] = log0? 0 0 0 Pass
12.3 TestSW: [HALL_A (PB4)] = log1? 16 16 16 Pass
12.4 TestSW: [HALL_B (PB5)] = log0? 0 0 0 Pass
12.5 TestSW: [HALL_B (PB5)] = log1? 32 32 32 Pass
12.6 TestSW: [HALL_C (PB0)] = log0? 0 0 0 Pass
12.7 TestSW: [HALL_C (PB0)] = log1? 1 1 1 Pass
13.1 TestSW: [CON_ID (PC13)] = log1? 8192 8192 8192 Pass
13.10 TestSW: [BTN_FFWD][ADC_PA6]? 4067 4000 4096 Pass
13.11 TestSW: [BTN_FFWD][ADC_PA6]? 2027 1900 2100 Pass
13.12 TestSW: [BTN_STOP][ADC_PA5]? 4066 4000 4096 Pass
13.13 TestSW: [BTN_STOP][ADC_PA5]? 2018 1900 2100 Pass
13.2 TestSW: [CON_ID (PC13)] = log0? 0 0 0 Pass
13.3 TestSW: [BTN_DRV][PA11] na log1 Pass
13.4 TestSW: [BTN_FWD][ADC_PB1]? 4065 4000 4096 Pass
13.5 TestSW: [BTN_FWD][ADC_PB1]? 1991 1900 2100 Pass
13.6 TestSW: [BTN_REV][ADC_PA4]? 4067 4000 4096 Pass
13.7 TestSW: [BTN_REV][ADC_PA4]? 2021 1900 2100 Pass
13.8 TestSW: [BTN_ULCK][ADC_PA7]? 4067 4000 4096 Pass
13.9 TestSW: [BTN_ULCK][ADC_PA7]? 2018 1900 2100 Pass
14.1 TestSW: [LED1][PB2] na log1 Pass
14.10 DMM: Měření napětí: LED3 (TP49/TP14) 3.30818868 > 3 Pass
14.11 TestSW: [LED3][PB11] na log0 Pass
14.12 DMM: Měření napětí: LED3 (TP49/TP14) 0.00345810414 < 0.1 Pass
14.13 TestSW: [LED4][PB12] na log1 Pass
14.14 DMM: Měření napětí: LED4 (TP49/TP12) 3.30937656 > 3 Pass
14.15 TestSW: [LED4][PB12] na log0 Pass
14.16 DMM: Měření napětí: LED4 (TP49/TP12) 0.00344825958 < 0.1 Pass
14.2 DMM: Měření napětí: LED1 (TP49/TP13) 3.27815501 > 3 Pass
14.3 TestSW: [LED1][PB2] na log0 Pass
14.4 DMM: Měření napětí: LED1 (TP49/TP13) 0.0035742927 < 0.1 Pass
14.5 TestSW: [LED2][PB10] na log1 Pass
14.6 DMM: Měření napětí: LED1 (TP49/TP11) 3.30814951 > 3 Pass
14.7 TestSW: [LED2][PB10] na log0 Pass
14.8 DMM: Měření napětí: LED1 (TP49/TP11) 0.00347332295 < 0.1 Pass
14.9 TestSW: [LED3][PB11] na log1 Pass
15.1 TestSW: ntc 95 49 90 Fail

Measurements over time

Hover for exact values · drag to zoom · double-click to reset

Readings (2)
DateValueMinMax
2026-07-09 15:55 0.958 10
2026-07-09 15:56 0.955 10