Serial 001791554
Tests10
Approved1
Failures9
Tests over time
Test history
| Date | Measurement ID | ID record | Article | Result | |
|---|---|---|---|---|---|
| 2024-09-09 06:05 | 300 | 638614515003811653-2194 | S0001055 | Fail | View |
| 2024-09-09 06:45 | 301 | 638614538659523728-5364 | S0001055 | Fail | View |
| 2024-09-23 09:05 | 512 | 638626718944731491-1685 | S0001055 | Fail | View |
| 2024-12-05 15:16 | 5405 | 638690049161350754-3563 | S0001055 | Fail | View |
| 2024-12-05 15:29 | 5406 | 638690057022146229-3694 | S0001055 | Fail | View |
| 2025-09-05 11:22 | 25763 | 638926608887503626-5997 | S0001055 | Fail | View |
| 2025-11-06 17:38 | 40587 | 638980438864132549-2310 | S0001055 | Fail | View |
| 2026-07-09 15:19 | 77765 | 639192071045395878-6412 | S0001055 | Fail | View |
| 2026-07-09 15:20 | 77766 | 639192071682686087-8706 | S0001055 | Fail | View |
| 2026-07-09 15:21 | 77767 | 639192072331082290-1031 | S0001055 | Pass | View |
Test 512
- Result
- Fail
- Date
- 2024-09-23 09:05
- Article
- S0001055
- ID record
- 638626718944731491-1685
- ID production
- 49267
- Temperature
- 25,92
- Humidity
- 37,06
- Test duration
- 55
- Error ID
- 371
- Error text
- TestSW: [ADC_PA1] sense B
Measurement lines
| Step | Name | Value | Min | Max | Result |
|---|---|---|---|---|---|
| 0.3 | Uložení teploty okolí | 25,92 | Pass | ||
| 0.4 | Uložení vlhkosti okolí | 37,06 | Pass | ||
| 0.5 | Uložení Id testeru (uloženo na lokálním disku) | Vez_Hokami_01-v01.01 | Pass | ||
| 0.6 | Uložení id Artiklu (produktové číslo) | S0001055 | Pass | ||
| 1.1 | DMM: Kontrola hodnoty Odporu (TP6/TP4) | 0,560530234 | < | 10 | Pass |
| 1.2 | DMM: Kontrola hodnoty Odporu (TP6/TP5) | 1000,69608 | 800 | 1200 | Pass |
| 3.1 | NZ3.1: Měření napětí: Zkrat? | 28,00651 | > | 27,9 | Pass |
| 3.2 | NZ3.1: Měření proudu: Kontrola odběru | 0,00084707 | < | 0,005 | Pass |
| 3.3 | R11.12: Zapnutí (TP42/TP43) | Pass | |||
| 3.4 | NZ3.1: Měření napětí: Zkrat? | 28,00851 | > | 27,9 | Pass |
| 3.5 | NZ3.1: Měření proudu: Kontrola odběru | 0,02422441 | < | 0,04 | Pass |
| 4.1 | DMM: Měření napětí: +BATT (TP49/TP44) | 27,9803818 | 27,9 | 28,1 | Pass |
| 4.2 | DMM: Měření napětí: +BATT (TP49/TP34) | 27,9986533 | 27,9 | 28,1 | Pass |
| 4.3 | DMM: Měření napětí: +12V (TP49/TP46) | 11,9099203 | 11 | 12,2 | Pass |
| 4.4 | DMM: Měření napětí: +5V (TP49/TP7) | 4,98463202 | 4,9 | 5,1 | Pass |
| 4.5 | DMM: Měření napětí: +3V3 (TP49/TP16) | 3,30313018 | 3,2 | 3,4 | Pass |
| 4.6 | DMM: Měření napětí: VDDA +3V3 (TP49/TP2) | 3,30314021 | 3,2 | 3,4 | Pass |
| 4.7 | DMM: Měření napětí: (TP49/TP8) | 4,66623394 | 4,57 | 4,77 | Pass |
| 4.8 | DMM: Měření napětí: (TP49/TP9) | 4,66329162 | 4,57 | 4,77 | Pass |
| 4.9 | DMM: Měření napětí: (TP49/TP10) | 4,66294397 | 4,57 | 4,77 | Pass |
| 5.1 | DMM: Měření napětí: (TP49/TP46) | 0,52573206 | < | 1 | Pass |
| 5.2 | DMM: Měření napětí: (TP49/TP46) | 11,8291719 | > | 11,5 | Pass |
| 6.1 | R9.12: Vypnutí (TP49/TP28) | Pass | |||
| 7.1 | NZ3: Měření napětí: Zkrat? | 28,00851 | > | 27,9 | Pass |
| 7.2 | NZ3: Měření proudu: Kontrola odběru | 0,0256595 | < | 0,06 | Pass |
| 7.3 | R0.6: Zapnutí Ext. Programátoru | Pass | |||
| 8.1 | TestSw: Ověření komunikace | [TYP:AA NAME:eDrive NAME2:TestSW HW:Kolecko v4 SW: | Pass | ||
| 9.1 | TestSW: [CHG_SIG (PC14)] = log1? | 16384 | 16384 | 16384 | Pass |
| 9.2 | EL1.1: Ověření proudu na zátěži -> Current? | 2,112764 | 1,6 | 2,8 | Pass |
| 9.3 | DMM: Měření napětí: Vstup U14 (TP39/TP32) | 29,6583751 | 29 | 30,1 | Pass |
| 9.4 | DMM: Měření napětí: Vstup U14 (TP39/TP33) | 11,2320423 | 10,8 | 11,5 | Pass |
| 9.5 | DMM: Měření napětí: Vstup U14 (TP39/TP40) | 1,63497123 | 1,5 | 1,8 | Pass |
| 10.1 | NZ3.1: Měření napětí: Zkrat? | 28,00651 | > | 27,9 | Pass |
| 10.2 | NZ3.1: Měření proudu: Kontrola odběru | 0,02556815 | < | 0,06 | Pass |
| 10.3 | TestSW: [ADC_PA03] | 3844 | 3667 | 3937 | Pass |
| 12.1 | TestSW: [PA15] - napájení sense ABC | Pass | |||
| 12.2 | TestSW: [HALL_A (PB4)] = log0? | 0 | 0 | 0 | Pass |
| 12.3 | TestSW: [HALL_A (PB4)] = log1? | 16 | 16 | 16 | Pass |
| 12.4 | TestSW: [HALL_B (PB5)] = log0? | 0 | 0 | 0 | Pass |
| 12.5 | TestSW: [HALL_B (PB5)] = log1? | 32 | 32 | 32 | Pass |
| 12.6 | TestSW: [HALL_C (PB0)] = log0? | 0 | 0 | 0 | Pass |
| 12.7 | TestSW: [HALL_C (PB0)] = log1? | 1 | 1 | 1 | Pass |
| 13.1 | TestSW: [CON_ID (PC13)] = log1? | 8192 | 8192 | 8192 | Pass |
| 13.10 | TestSW: [BTN_FFWD][ADC_PA6]? | 4085 | 4000 | 4096 | Pass |
| 13.11 | TestSW: [BTN_FFWD][ADC_PA6]? | 2055 | 1900 | 2100 | Pass |
| 13.12 | TestSW: [BTN_STOP][ADC_PA5]? | 4086 | 4000 | 4096 | Pass |
| 13.13 | TestSW: [BTN_STOP][ADC_PA5]? | 2026 | 1900 | 2100 | Pass |
| 13.2 | TestSW: [CON_ID (PC13)] = log0? | 0 | 0 | 0 | Pass |
| 13.3 | TestSW: [BTN_DRV][PA11] na log1 | Pass | |||
| 13.4 | TestSW: [BTN_FWD][ADC_PB1]? | 4085 | 4000 | 4096 | Pass |
| 13.5 | TestSW: [BTN_FWD][ADC_PB1]? | 2013 | 1900 | 2100 | Pass |
| 13.6 | TestSW: [BTN_REV][ADC_PA4]? | 4085 | 4000 | 4096 | Pass |
| 13.7 | TestSW: [BTN_REV][ADC_PA4]? | 2023 | 1900 | 2100 | Pass |
| 13.8 | TestSW: [BTN_ULCK][ADC_PA7]? | 4085 | 4000 | 4096 | Pass |
| 13.9 | TestSW: [BTN_ULCK][ADC_PA7]? | 2025 | 1900 | 2100 | Pass |
| 14.1 | TestSW: [LED1][PB2] na log1 | Pass | |||
| 14.10 | DMM: Měření napětí: LED3 (TP49/TP14) | 3,29861978 | > | 3 | Pass |
| 14.11 | TestSW: [LED3][PB11] na log0 | Pass | |||
| 14.12 | DMM: Měření napětí: LED3 (TP49/TP14) | 0,00355374291 | < | 0,1 | Pass |
| 14.13 | TestSW: [LED4][PB12] na log1 | Pass | |||
| 14.14 | DMM: Měření napětí: LED4 (TP49/TP12) | 3,2999506 | > | 3 | Pass |
| 14.15 | TestSW: [LED4][PB12] na log0 | Pass | |||
| 14.16 | DMM: Měření napětí: LED4 (TP49/TP12) | 0,00353823861 | < | 0,1 | Pass |
| 14.2 | DMM: Měření napětí: LED1 (TP49/TP13) | 3,29846361 | > | 3 | Pass |
| 14.3 | TestSW: [LED1][PB2] na log0 | Pass | |||
| 14.4 | DMM: Měření napětí: LED1 (TP49/TP13) | 0,00366301685 | < | 0,1 | Pass |
| 14.5 | TestSW: [LED2][PB10] na log1 | Pass | |||
| 14.6 | DMM: Měření napětí: LED1 (TP49/TP11) | 3,29858789 | > | 3 | Pass |
| 14.7 | TestSW: [LED2][PB10] na log0 | Pass | |||
| 14.8 | DMM: Měření napětí: LED1 (TP49/TP11) | 0,00354863209 | < | 0,1 | Pass |
| 14.9 | TestSW: [LED3][PB11] na log1 | Pass | |||
| 15.1 | TestSW: ntc | 59 | 49 | 90 | Pass |
| 16.1 | DMM: Měření frekvence (TP49/TP55) | 19994,9874 | 19600 | 20400 | Pass |
| 16.2 | DMM: Měření frekvence (TP49/TP56) | 19994,984 | 19600 | 20400 | Pass |
| 16.3 | DMM: Měření napětí (TP49/TP52) | 14,0090103 | 13,3 | 14,7 | Pass |
| 17.1 | DMM: Měření frekvence (TP49/TP61) | 19994,978 | 19600 | 20400 | Pass |
| 17.2 | DMM: Měření frekvence (TP49/TP62) | 19994,9855 | 19600 | 20400 | Pass |
| 17.3 | DMM: Měření napětí (TP49/TP58) | 14,0054351 | 13,3 | 14,7 | Pass |
| 18.1 | DMM: Měření frekvence (TP49/TP67) | 19994,9799 | 19600 | 20400 | Pass |
| 18.2 | DMM: Měření frekvence (TP49/TP68) | 19994,9822 | 19600 | 20400 | Pass |
| 18.3 | DMM: Měření napětí (TP49/TP58) | 14,0104305 | 13,3 | 14,7 | Pass |
| 19.1 | DMM: Měření napětí: +5V (TP49/TP7) | -0,000632831316 | < | 0,5 | Pass |
| 20.0.3 | TestSW: [ADC_PA2] sense C do var | VC = 2264 | Pass | ||
| 20.0.7 | Analysis: VC | VC[2264] | 2210 | 2340 | Pass |
| 20.0.6 | Analysis: VB | VB[2257] | 2210 | 2340 | Pass |
| 20.0.5 | Analysis: VA | VA[2258] | 2210 | 2340 | Pass |
| 20.0.2 | TestSW: [ADC_PA1] sense B do var | VB = 2257 | Pass | ||
| 20.0.1 | TestSW: [ADC_PA0] sense A do var | VA = 2258 | Pass | ||
| 20.1 | NZ3.1: Měření napětí: Zkrat? | 28,00851 | > | 27,9 | Pass |
| 20.1.1 | EL1.2: Ověření proudu na zátěži -> Current? | 4,989742 | 4,7 | 5,3 | Pass |
| 20.1.2 | TestSW: [ADC_PA0] sense A | 2427 | 2423[VA] | 2523[VA] | Pass |
| 20.1.3 | TestSW: [ADC_PA1] sense B | 2092 | 1992[VB] | 2092[VB] | Pass |
| 20.1.4 | TestSW: [ADC_PA2] sense C | 2265 | 2210 | 2340 | Pass |
| 20.2 | NZ3.1: Měření proudu: Kontrola odběru | 0,03816887 | < | 0,06 | Pass |
| 20.2.1 | EL1.2: Ověření proudu na zátěži -> Current? | 4,989787 | 4,7 | 5,3 | Pass |
| 20.2.2 | TestSW: [ADC_PA0] sense A | 2088 | 1993[VA] | 2093[VA] | Pass |
| 20.2.3 | TestSW: [ADC_PA1] sense B | 2421 | 2422[VB] | 2522[VB] | Fail |
Measurements over time
Hover for exact values · drag to zoom · double-click to reset
Readings (3)
| Date | Value | Min | Max |
|---|---|---|---|
| 2026-07-09 15:19 | 0.994 | — | 10 |
| 2026-07-09 15:20 | 0.958 | — | 10 |
| 2026-07-09 15:21 | 0.953 | — | 10 |