Serial 001791407
Tests2
Approved1
Failures1
Tests over time
Test history
| Date | Measurement ID | ID record | Article | Result | |
|---|---|---|---|---|---|
| 2024-09-04 14:31 | 51 | 638610499075867476-3211 | S0001055 | Fail | View |
| 2024-09-04 14:52 | 52 | 638610511042740891-8448 | S0001055 | Pass | View |
Test 51
- Result
- Fail
- Date
- 2024-09-04 14:31
- Article
- S0001055
- ID record
- 638610499075867476-3211
- ID production
- 49267
- Temperature
- 31,02
- Humidity
- 33,45
- Test duration
- 11
- Error ID
- 109
- Error text
- DMM: Měření napětí: +BATT (TP49/TP34)
Measurement lines
| Step | Name | Value | Min | Max | Result |
|---|---|---|---|---|---|
| 0.3 | Uložení teploty okolí | 31,02 | Pass | ||
| 0.4 | Uložení vlhkosti okolí | 33,45 | Pass | ||
| 0.5 | Uložení Id testeru (uloženo na lokálním disku) | Vez_Hokami_01-v01.01 | Pass | ||
| 0.6 | Uložení id Artiklu (produktové číslo) | S0001055 | Pass | ||
| 1.1 | DMM: Kontrola hodnoty Odporu (TP6/TP4) | 0,661754996 | < | 10 | Pass |
| 1.2 | DMM: Kontrola hodnoty Odporu (TP6/TP5) | 995,946467 | 800 | 1200 | Pass |
| 3.1 | NZ3.1: Měření napětí: Zkrat? | 28,00851 | > | 27,9 | Pass |
| 3.2 | NZ3.1: Měření proudu: Kontrola odběru | 0,001389267 | < | 0,005 | Pass |
| 3.3 | R11.12: Zapnutí (TP42/TP43) | Pass | |||
| 3.4 | NZ3.1: Měření napětí: Zkrat? | 28,00851 | > | 27,9 | Pass |
| 3.5 | NZ3.1: Měření proudu: Kontrola odběru | 0,02454264 | < | 0,04 | Pass |
| 4.1 | DMM: Měření napětí: +BATT (TP49/TP44) | 27,9763386 | 27,9 | 28,1 | Pass |
| 4.2 | DMM: Měření napětí: +BATT (TP49/TP34) | 12,4016847 | 27,9 | 28,1 | Fail |