Testing Portal everyone (auth disabled)

Serial lookup

Search a serial number to see its full test history.

Serial 001791569

Tests8
Approved2
Failures6

Tests over time

Test history

DateMeasurement IDID recordArticleResult
2024-09-04 15:01 101 638610516788484721-1751 S0001055 Fail View
2024-09-04 15:21 102 638610528905440094-1406 S0001055 Fail View
2024-09-23 09:20 520 638626727960579126-6443 S0001055 Fail View
2024-09-24 14:37 555 638627782107105054-2811 S0001055 Fail View
2024-12-05 15:01 5417 638690040871512392-8265 S0001055 Fail View
2024-12-05 15:33 5418 638690060117435837-9406 S0001055 Fail View
2025-09-05 11:03 25769 638926597548983250-7725 S0001055 Pass View
2026-01-16 05:22 48478 639041376809295382-9172 S0001055 Pass View

Test 48478

Result
Pass
Date
2026-01-16 05:22
Article
S0001055
ID record
639041376809295382-9172
ID production
54744
Temperature
25.36
Humidity
28.56
Test duration
68
Error ID
Error text

Measurement lines

StepNameValueMinMaxResult
1.1 DMM: Kontrola hodnoty Odporu (TP6/TP4) 0.858973771 < 10 Pass
1.2 DMM: Kontrola hodnoty Odporu (TP6/TP5) 1001.36345 800 1200 Pass
3.1 NZ3.1: Měření napětí: Zkrat? 28.00651 > 27.9 Pass
3.2 NZ3.1: Měření proudu: Kontrola odběru 0.001144701 < 0.005 Pass
3.3 R11.12: Zapnutí (TP42/TP43) Pass
3.4 NZ3.1: Měření napětí: Zkrat? 28.00651 > 27.9 Pass
3.5 NZ3.1: Měření proudu: Kontrola odběru 0.02474895 < 0.04 Pass
4.1 DMM: Měření napětí: +BATT (TP49/TP44) 27.9674891 27.9 28.1 Pass
4.2 DMM: Měření napětí: +BATT (TP49/TP34) 27.9954207 27.9 28.1 Pass
4.3 DMM: Měření napětí: +12V (TP49/TP46) 11.8313205 11 12.2 Pass
4.4 DMM: Měření napětí: +5V (TP49/TP7) 4.99729737 4.9 5.1 Pass
4.5 DMM: Měření napětí: +3V3 (TP49/TP16) 3.31187929 3.2 3.4 Pass
4.6 DMM: Měření napětí: VDDA +3V3 (TP49/TP2) 3.31189544 3.2 3.4 Pass
4.7 DMM: Měření napětí: (TP49/TP8) 4.67789291 4.57 4.77 Pass
4.8 DMM: Měření napětí: (TP49/TP9) 4.67483038 4.57 4.77 Pass
4.9 DMM: Měření napětí: (TP49/TP10) 4.67445272 4.57 4.77 Pass
5.1 DMM: Měření napětí: (TP49/TP46) 0.516970991 < 1 Pass
5.2 DMM: Měření napětí: (TP49/TP46) 11.7423533 > 11.5 Pass
6.1 R9.12: Vypnutí (TP49/TP28) Pass
7.1 NZ3: Měření napětí: Zkrat? 28.00651 > 27.9 Pass
7.2 NZ3: Měření proudu: Kontrola odběru 0.01103727 < 0.06 Pass
7.3 R0.6: Zapnutí Ext. Programátoru Pass
8.1 TestSw: Ověření komunikace [TYP:AA NAME:eDrive NAME2:TestSW HW:Kolecko v4 SW: Pass
9.1 TestSW: [CHG_SIG (PC14)] = log1? 16384 16384 16384 Pass
9.2 EL1.1: Ověření proudu na zátěži -> Current? 2.095406 1.6 2.8 Pass
9.3 DMM: Měření napětí: Vstup U14 (TP39/TP32) 29.6183873 29 30.1 Pass
9.4 DMM: Měření napětí: Vstup U14 (TP39/TP33) 11.265325 10.8 11.5 Pass
9.5 DMM: Měření napětí: Vstup U14 (TP39/TP40) 1.62656059 1.5 1.8 Pass
10.1 NZ3.1: Měření napětí: Zkrat? 28.00651 > 27.9 Pass
10.2 NZ3.1: Měření proudu: Kontrola odběru 0.0252617 < 0.06 Pass
10.3 TestSW: [ADC_PA03] 3836 3667 3937 Pass
12.1 TestSW: [PA15] - napájení sense ABC Pass
12.2 TestSW: [HALL_A (PB4)] = log0? 0 0 0 Pass
12.3 TestSW: [HALL_A (PB4)] = log1? 16 16 16 Pass
12.4 TestSW: [HALL_B (PB5)] = log0? 0 0 0 Pass
12.5 TestSW: [HALL_B (PB5)] = log1? 32 32 32 Pass
12.6 TestSW: [HALL_C (PB0)] = log0? 0 0 0 Pass
12.7 TestSW: [HALL_C (PB0)] = log1? 1 1 1 Pass
13.1 TestSW: [CON_ID (PC13)] = log1? 8192 8192 8192 Pass
13.10 TestSW: [BTN_FFWD][ADC_PA6]? 4086 4000 4096 Pass
13.11 TestSW: [BTN_FFWD][ADC_PA6]? 2030 1900 2100 Pass
13.12 TestSW: [BTN_STOP][ADC_PA5]? 4086 4000 4096 Pass
13.13 TestSW: [BTN_STOP][ADC_PA5]? 2028 1900 2100 Pass
13.2 TestSW: [CON_ID (PC13)] = log0? 0 0 0 Pass
13.3 TestSW: [BTN_DRV][PA11] na log1 Pass
13.4 TestSW: [BTN_FWD][ADC_PB1]? 4086 4000 4096 Pass
13.5 TestSW: [BTN_FWD][ADC_PB1]? 2015 1900 2100 Pass
13.6 TestSW: [BTN_REV][ADC_PA4]? 4086 4000 4096 Pass
13.7 TestSW: [BTN_REV][ADC_PA4]? 2027 1900 2100 Pass
13.8 TestSW: [BTN_ULCK][ADC_PA7]? 4086 4000 4096 Pass
13.9 TestSW: [BTN_ULCK][ADC_PA7]? 2025 1900 2100 Pass
14.1 TestSW: [LED1][PB2] na log1 Pass
14.10 DMM: Měření napětí: LED3 (TP49/TP14) 3.30788423 > 3 Pass
14.11 TestSW: [LED3][PB11] na log0 Pass
14.12 DMM: Měření napětí: LED3 (TP49/TP14) 0.00344708984 < 0.1 Pass
14.13 TestSW: [LED4][PB12] na log1 Pass
14.14 DMM: Měření napětí: LED4 (TP49/TP12) 3.30918056 > 3 Pass
14.15 TestSW: [LED4][PB12] na log0 Pass
14.16 DMM: Měření napětí: LED4 (TP49/TP12) 0.00344722922 < 0.1 Pass
14.2 DMM: Měření napětí: LED1 (TP49/TP13) 3.30770933 > 3 Pass
14.3 TestSW: [LED1][PB2] na log0 Pass
14.4 DMM: Měření napětí: LED1 (TP49/TP13) 0.00354600215 < 0.1 Pass
14.5 TestSW: [LED2][PB10] na log1 Pass
14.6 DMM: Měření napětí: LED1 (TP49/TP11) 3.30784708 > 3 Pass
14.7 TestSW: [LED2][PB10] na log0 Pass
14.8 DMM: Měření napětí: LED1 (TP49/TP11) 0.0034622918 < 0.1 Pass
14.9 TestSW: [LED3][PB11] na log1 Pass
15.1 TestSW: ntc 64 49 90 Pass
16.1 DMM: Měření frekvence (TP49/TP55) 19995.0985 19600 20400 Pass
16.2 DMM: Měření frekvence (TP49/TP56) 19995.0985 19600 20400 Pass
16.3 DMM: Měření napětí (TP49/TP52) 14.011401 13.3 14.7 Pass
17.1 DMM: Měření frekvence (TP49/TP61) 19995.0929 19600 20400 Pass
17.2 DMM: Měření frekvence (TP49/TP62) 19995.0967 19600 20400 Pass
17.3 DMM: Měření napětí (TP49/TP58) 14.0025444 13.3 14.7 Pass
18.1 DMM: Měření frekvence (TP49/TP67) 19995.0929 19600 20400 Pass
18.2 DMM: Měření frekvence (TP49/TP68) 19995.0985 19600 20400 Pass
18.3 DMM: Měření napětí (TP49/TP58) 14.0135389 13.3 14.7 Pass
19.1 DMM: Měření napětí: +5V (TP49/TP7) 0.000700330963 < 0.5 Pass
20.0.5 Analysis: VA VA[2262] 2210 2340 Pass
20.0.6 Analysis: VB VB[2259] 2210 2340 Pass
20.0.7 Analysis: VC VC[2264] 2210 2340 Pass
20.1 NZ3.1: Měření napětí: Zkrat? 28.00651 > 27.9 Pass
20.1.1 EL1.2: Ověření proudu na zátěži -> Current? 4.989378 4.7 5.3 Pass
20.1.2 TestSW: [ADC_PA0] sense A 2438 2427[VA] 2527[VA] Pass
20.1.3 TestSW: [ADC_PA1] sense B 2090 1994[VB] 2094[VB] Pass
20.1.4 TestSW: [ADC_PA2] sense C 2265 2210 2340 Pass
20.2 NZ3.1: Měření proudu: Kontrola odběru 0.03811584 < 0.06 Pass
20.2.1 EL1.2: Ověření proudu na zátěži -> Current? 4.989261 4.7 5.3 Pass
20.2.2 TestSW: [ADC_PA0] sense A 2086 1997[VA] 2097[VA] Pass
20.2.3 TestSW: [ADC_PA1] sense B 2427 2424[VB] 2524[VB] Pass
20.2.4 TestSW: [ADC_PA2] sense C 2265 2210 2340 Pass
20.3.1 EL1.2: Ověření proudu na zátěži -> Current? 4.989247 4.7 5.3 Pass
20.3.2 TestSW: [ADC_PA0] sense A 2438 2427[VA] 2527[VA] Pass
20.3.3 TestSW: [ADC_PA1] sense B 2262 2210 2340 Pass
20.3.4 TestSW: [ADC_PA2] sense C 2094 1999[VC] 2099[VC] Pass
20.4.1 EL1.2: Ověření proudu na zátěži -> Current? 4.989349 4.7 5.3 Pass
20.4.2 TestSW: [ADC_PA0] sense A 2086 1997[VA] 2097[VA] Pass
20.4.3 TestSW: [ADC_PA1] sense B 2256 2210 2340 Pass
20.4.4 TestSW: [ADC_PA2] sense C 2435 2429[VC] 2529[VC] Pass
20.5.1 EL1.2: Ověření proudu na zátěži -> Current? 4.989447 4.7 5.3 Pass
20.5.2 TestSW: [ADC_PA0] sense A 2263 2210 2340 Pass
20.5.3 TestSW: [ADC_PA1] sense B 2431 2424[VB] 2524[VB] Pass
20.5.4 TestSW: [ADC_PA2] sense C 2094 1999[VC] 2099[VC] Pass
20.6.1 EL1.2: Ověření proudu na zátěži -> Current? 4.989367 4.7 5.3 Pass
20.6.2 TestSW: [ADC_PA0] sense A 2262 2210 2340 Pass
20.6.3 TestSW: [ADC_PA1] sense B 2087 1994[VB] 2094[VB] Pass
20.6.4 TestSW: [ADC_PA2] sense C 2435 2429[VC] 2529[VC] Pass
23.1 DMM: měření RMS(TP49/TP67) 0.100417785 0.1 1.6 Pass

Measurements over time

Hover for exact values · drag to zoom · double-click to reset

Readings (1)
DateValueMinMax
2026-01-16 05:22 0.859 10