Testing Portal everyone (auth disabled)

Serial lookup

Search a serial number to see its full test history.

Serial 001676194

Tests3
Approved2
Failures1

Tests over time

Test history

DateMeasurement IDID recordArticleResult
2025-09-05 09:54 25786 638926555998518653-1116 S0001055 Pass View
2026-01-15 12:25 48439 639040767133314386-8181 S0001055 Fail View
2026-01-15 12:26 48440 639040767336332631-5180 S0001055 Pass View

Test 48439

Result
Fail
Date
2026-01-15 12:25
Article
S0001055
ID record
639040767133314386-8181
ID production
54744
Temperature
25.99
Humidity
29.1
Test duration
11
Error ID
112
Error text
DMM: Měření napětí: +12V (TP49/TP46)

Measurement lines

StepNameValueMinMaxResult
1.1 DMM: Kontrola hodnoty Odporu (TP6/TP4) 0.634960641 < 10 Pass
1.2 DMM: Kontrola hodnoty Odporu (TP6/TP5) 1001.56573 800 1200 Pass
3.1 NZ3.1: Měření napětí: Zkrat? 28.00851 > 27.9 Pass
3.2 NZ3.1: Měření proudu: Kontrola odběru 0.00209651 < 0.005 Pass
3.3 R11.12: Zapnutí (TP42/TP43) Pass
3.4 NZ3.1: Měření napětí: Zkrat? 28.00851 > 27.9 Pass
3.5 NZ3.1: Měření proudu: Kontrola odběru 0.02524399 < 0.04 Pass
4.1 DMM: Měření napětí: +BATT (TP49/TP44) 27.9626377 27.9 28.1 Pass
4.2 DMM: Měření napětí: +BATT (TP49/TP34) 27.9949171 27.9 28.1 Pass
4.3 DMM: Měření napětí: +12V (TP49/TP46) 0.0416070215 11 12.2 Fail

Measurements over time

Hover for exact values · drag to zoom · double-click to reset

Readings (2)
DateValueMinMax
2026-01-15 12:25 0.635 10
2026-01-15 12:26 0.619 10