Testing Portal everyone (auth disabled)

Serial lookup

Search a serial number to see its full test history.

Serial 001967246

Tests11
Approved0
Failures11

Tests over time

Test history

DateMeasurement IDID recordArticleResult
2025-07-10 09:51 21607 638877306821805246-9085 Fail View
2025-07-10 09:51 21608 638877306965666756-7860 Fail View
2025-07-10 10:14 21609 638877320752645589-1992 Fail View
2025-07-11 09:34 21830 638878160732238999-1492 Fail View
2025-07-11 09:34 21831 638878160868502584-1897 Fail View
2025-07-11 09:35 21832 638878161400204145-5485 Fail View
2025-07-29 07:52 22783 638893651633317711-4559 Fail View
2025-07-29 09:34 22784 638893712916282068-8929 Fail View
2025-07-29 09:35 22785 638893713141275066-5056 Fail View
2025-08-27 10:34 48044 638918804579984457-3919 Fail View
2026-02-02 07:02 60982 639056089277267629-9324 S0001604 Fail View

Test 48044

Result
Fail
Date
2025-08-27 10:34
Article
ID record
638918804579984457-3919
ID production
52627
Temperature
26.89
Humidity
33.57
Test duration
4
Error ID
057
Error text
NZ3: Měření proudu: (TP2/TP9)

Measurement lines

StepNameValueMinMaxResult
0.0 Dekódování a uložení načteného SN 001967246 Pass
0.1 Uložení čísla výrobního příkazu 52627 Pass
0.2 Uložení ID obsluhy 0736 Pass
0.3 Uložení teploty okolí 26.89 Pass
0.4 Uložení vlhkosti okolí 33.57 Pass
0.6 DMM: Status? 0000000000000000 xxxxxxxxx000000x Pass
0.7 NZ3: Status? 0000000000000000 xxxxxxxxx000000x Pass
0.8 EL: Status? 0000000000000000 xxxxxxxxx000000x Pass
1.1 DMM: Kontrola hodnoty Odporu (TP7/TP8) 100.480134 95 105 Pass
2.1 NZ3: Měření proudu: (TP2/TP9) 0.00946517 0.002 0.008 Fail

Measurements over time

Hover for exact values · drag to zoom · double-click to reset

Readings (1)
DateValueMinMax
2026-02-02 07:02 1967246