Serial 001855291
Tests3
Approved0
Failures3
Tests over time
Test history
| Date | Measurement ID | ID record | Article | Result | |
|---|---|---|---|---|---|
| 2025-08-27 10:01 | 47990 | 638918785008672834-7632 | Fail | View | |
| 2025-08-27 10:14 | 47991 | 638918792858251628-9706 | Fail | View | |
| 2026-02-02 07:08 | 60965 | 639056092832433766-5346 | S0001604 | Fail | View |
Test 47990
- Result
- Fail
- Date
- 2025-08-27 10:01
- Article
- ID record
- 638918785008672834-7632
- ID production
- 51291
- Temperature
- 26.78
- Humidity
- 32.92
- Test duration
- 4
- Error ID
- 057
- Error text
- NZ3: Měření proudu: (TP2/TP9)
Measurement lines
| Step | Name | Value | Min | Max | Result |
|---|---|---|---|---|---|
| 0.0 | Dekódování a uložení načteného SN | 001855291 | Pass | ||
| 0.1 | Uložení čísla výrobního příkazu | 51291 | Pass | ||
| 0.2 | Uložení ID obsluhy | 0736 | Pass | ||
| 0.3 | Uložení teploty okolí | 26.78 | Pass | ||
| 0.4 | Uložení vlhkosti okolí | 32.92 | Pass | ||
| 0.6 | DMM: Status? | 0000000000000000 | xxxxxxxxx000000x | Pass | |
| 0.7 | NZ3: Status? | 0000000000000000 | xxxxxxxxx000000x | Pass | |
| 0.8 | EL: Status? | 0000000000000000 | xxxxxxxxx000000x | Pass | |
| 1.1 | DMM: Kontrola hodnoty Odporu (TP7/TP8) | 100.488474 | 95 | 105 | Pass |
| 2.1 | NZ3: Měření proudu: (TP2/TP9) | 0.008153822 | 0.002 | 0.008 | Fail |
Measurements over time
Hover for exact values · drag to zoom · double-click to reset
Readings (1)
| Date | Value | Min | Max |
|---|---|---|---|
| 2026-02-02 07:08 | 1855291 | — | — |