Serial lookup
Search a serial number to see its full test history.
Serial 001006225
Tests2
Approved1
Failures1
Tests over time
Test history
| Date | Measurement ID | ID record | Article | Result | |
|---|---|---|---|---|---|
| 2024-09-23 08:04 | 477 | 638626682677611631-6597 | S0001055 | Fail | View |
| 2024-12-05 14:08 | 5377 | 638690008531335680-4070 | S0001055 | Pass | View |
Test 477
- Result
- Fail
- Date
- 2024-09-23 08:04
- Article
- S0001055
- ID record
- 638626682677611631-6597
- ID production
- 49265
- Temperature
- 25,71
- Humidity
- 36,34
- Test duration
- 11
- Error ID
- 112
- Error text
- DMM: Měření napětí: +12V (TP49/TP46)
Measurement lines
| Step | Name | Value | Min | Max | Result |
|---|---|---|---|---|---|
| 0.3 | Uložení teploty okolí | 25,71 | Pass | ||
| 0.4 | Uložení vlhkosti okolí | 36,34 | Pass | ||
| 0.5 | Uložení Id testeru (uloženo na lokálním disku) | Vez_Hokami_01-v01.01 | Pass | ||
| 0.6 | Uložení id Artiklu (produktové číslo) | S0001055 | Pass | ||
| 1.1 | DMM: Kontrola hodnoty Odporu (TP6/TP4) | 0,599802452 | < | 10 | Pass |
| 1.2 | DMM: Kontrola hodnoty Odporu (TP6/TP5) | 1002,40029 | 800 | 1200 | Pass |
| 3.1 | NZ3.1: Měření napětí: Zkrat? | 28,00651 | > | 27,9 | Pass |
| 3.2 | NZ3.1: Měření proudu: Kontrola odběru | 0,0005229168 | < | 0,005 | Pass |
| 3.3 | R11.12: Zapnutí (TP42/TP43) | Pass | |||
| 3.4 | NZ3.1: Měření napětí: Zkrat? | 28,00651 | > | 27,9 | Pass |
| 3.5 | NZ3.1: Měření proudu: Kontrola odběru | 0,02398277 | < | 0,04 | Pass |
| 4.1 | DMM: Měření napětí: +BATT (TP49/TP44) | 27,9711977 | 27,9 | 28,1 | Pass |
| 4.2 | DMM: Měření napětí: +BATT (TP49/TP34) | 27,9988777 | 27,9 | 28,1 | Pass |
| 4.3 | DMM: Měření napětí: +12V (TP49/TP46) | 0,00417993517 | 11 | 12,2 | Fail |
Measurements over time
Hover for exact values · drag to zoom · double-click to reset
Readings (2)
| Date | Value | Min | Max |
|---|---|---|---|
| 2024-09-23 08:04 | 25.71 | — | — |
| 2024-12-05 14:08 | 25.75 | — | — |