Serial lookup
Search a serial number to see its full test history.
Serial 001949100
Tests4
Approved2
Failures2
Tests over time
Test history
| Date | Measurement ID | ID record | Article | Result | |
|---|---|---|---|---|---|
| 2025-12-09 09:18 | 45202 | 639008650295115629-9375 | S0004026 | Fail | View |
| 2025-12-09 09:20 | 45203 | 639008651322935156-3942 | S0004026 | Fail | View |
| 2025-12-09 09:53 | 45204 | 639008671133177559-4069 | S0004026 | Pass | View |
| 2025-12-09 14:22 | 45205 | 639008832609200312-1888 | S0004026 | Pass | View |
Test 45203
- Result
- Fail
- Date
- 2025-12-09 09:20
- Article
- S0004026
- ID record
- 639008651322935156-3942
- ID production
- 52054
- Temperature
- 25.19
- Humidity
- 44.81
- Test duration
- 71
- Error ID
- 452
- Error text
- Vyhodnocení programu: [updateBin]
Measurement lines
| Step | Name | Value | Min | Max | Result |
|---|---|---|---|---|---|
| 0.0 | Dekódování a uložení načteného SN | 001949100 | Pass | ||
| Vypnutí K2.A6 (TP17,18/NZ1-) | Pass | ||||
| 0.1 | Uložení čísla výrobního příkazu | 52054 | Pass | ||
| 0.2 | Uložení ID obsluhy | 0008 | Pass | ||
| 0.3 | Uložení teploty okolí | 25.19 | Pass | ||
| 0.4 | Uložení vlhkosti okolí | 44.81 | Pass | ||
| 0.5 | Uložení Id testeru (uloženo na lokálním disku) | Vez_Hokami_01-v01.01 | Pass | ||
| 0.6 | Uložení id Artiklu (produktové číslo) | S0004026 | Pass | ||
| 1.1 | DMM: Kontrola hodnoty Odporu (TP2/TP3) | 2.41966315 | -1 | 5 | Pass |
| 1.2 | DMM: Kontrola hodnoty Odporu (TP4/TP3) | 7516.59495 | 7400 | 7600 | Pass |
| 1.3 | DMM: Kontrola hodnoty Odporu (TP27/TP17,18) | 10163.1962 | 9000 | 11000 | Pass |
| 2.1 | DMM: Kontrola hodnoty Odporu (TP8/TP10) | 1075.76246 | 1012 | 1120 | Pass |
| 4.1 | NZ1: Odběr proudu ze zdroje (TP6/TP17,18) | 0.002900843 | 0.0025 | 0.006 | Pass |
| 4.2 | DMM: Kontrola hodnoty napětí (TP5/TP17,18) | 11.9975462 | 11.9 | 12.1 | Pass |
| 4.3 | DMM: Kontrola hodnoty napětí (TP19/TP17,18) | 4.9697587 | 4.9 | 5.1 | Pass |
| 4.4 | DMM: Kontrola hodnoty napětí (TP20/TP17,18) | 3.29332872 | 3.2 | 3.4 | Pass |
| 4.5 | DMM: Kontrola hodnoty napětí (TP21/TP17,18) | 3.29317624 | 3.2 | 3.4 | Pass |
| 4.6 | DMM: Kontrola hodnoty napětí (TP31/TP17,18) | 3.292216 | 3.2 | 3.4 | Pass |
| 4.7 | DMM: Kontrola hodnoty napětí (TP36/TP17,18) | 4.9697269 | 4.9 | 5.1 | Pass |
| 4.8 | DMM: Kontrola hodnoty napětí (TP38/TP17,18) | 3.29322266 | 3.2 | 3.4 | Pass |
| 5.0 | DMM: Kontrola hodnoty napětí (TP12/TP17,18) | 0.000892313336 | < | 0.1 | Pass |
| 5.1 | DMM: Kontrola hodnoty napětí (TP12/TP17,18) | 2.84123861 | 2.54 | 3.14 | Pass |
| 8.1 | Vyhodnocení programu: [testSW] | 0 | Pass | ||
| 8.1 | Vyhodnocení programu: [testSW] | Running... | Fail | ||
| 12.1 | Test komunikace mezi U2 a U3 přes RS485 | 0 (0x00) | 0 (0x00) | 0 (0x00) | Pass |
| 13.1 | DMM: Změřit napětí + 3V3 a uložit (TP20/TP17,18) | VarDouble: d_3V3 = 3.2943052700000002 | Pass | ||
| 13.2 | DMM: Změřit napětí VCC_PER a uložit (TP5/TP17,18) | VarDouble: d_VCC_PER = 11.9886436 | Pass | ||
| 13.3 | Načtení hodnoty ADC z PC4 (VBATT_ADC) a uložení | d_VBATT_ADC=3170 | Pass | ||
| 13.4 | Analysis: hodnota na max | True | d_VBATT_ADC[3170]<=d_max[3205.01484357969] | Pass | |
| 13.5 | Analysis: hodnota na min | True | d_VBATT_ADC[3170]>=d_min[3145.01484357969] | Pass | |
| 15.1 | DMM: Kontrola hodnoty napětí (TP32/TP17,18) | 3.28637637 | > | 3 | Pass |
| 15.2 | DMM: Kontrola hodnoty napětí (TP32/TP17,18) | 0.00101725895 | < | 0.1 | Pass |
| 16.1 | DMM: Kontrola hodnoty napětí (TP33/TP17,18) | 3.28636644 | > | 3 | Pass |
| 16.2 | DMM: Kontrola hodnoty napětí (TP33/TP17,18) | 0.00138221678 | < | 0.1 | Pass |
| 17.1 | DMM: Kontrola hodnoty napětí (TP34/TP17,18) | 3.28636488 | > | 3 | Pass |
| 17.2 | DMM: Kontrola hodnoty napětí (TP34/TP17,18) | 0.00340739858 | < | 0.1 | Pass |
| 18.1 | DMM: Kontrola hodnoty napětí (TP35/TP17,18) | 3.28642704 | > | 3 | Pass |
| 18.2 | DMM: Kontrola hodnoty napětí (TP35/TP17,18) | 0.00192577319 | < | 0.1 | Pass |
| 19.1 | DMM: Kontrola hodnoty napětí (TP40/TP17,18) | 3.27561579 | > | 3 | Pass |
| 19.2 | DMM: Kontrola hodnoty napětí (TP41/TP17,18) | 0.00392471845 | < | 0.1 | Pass |
| 19.3 | DMM: Kontrola hodnoty napětí (TP42/TP17,18) | 0.00379193985 | < | 0.1 | Pass |
| 19.4 | DMM: Kontrola hodnoty napětí (TP43/TP17,18) | 0.00374497571 | < | 0.1 | Pass |
| 19.5 | DMM: Kontrola hodnoty napětí (TP44/TP17,18) | 0.00376482589 | < | 0.1 | Pass |
| 20.1 | DMM: Kontrola hodnoty napětí (TP40/TP17,18) | 0.0033797256 | < | 0.1 | Pass |
| 20.2 | DMM: Kontrola hodnoty napětí (TP41/TP17,18) | 3.29192484 | > | 3 | Pass |
| 20.3 | DMM: Kontrola hodnoty napětí (TP42/TP17,18) | 0.00367017334 | < | 0.1 | Pass |
| 20.4 | DMM: Kontrola hodnoty napětí (TP43/TP17,18) | 0.00366468857 | < | 0.1 | Pass |
| 20.5 | DMM: Kontrola hodnoty napětí (TP44/TP17,18) | 0.00364385732 | < | 0.1 | Pass |
| 21.1 | DMM: Kontrola hodnoty napětí (TP40/TP17,18) | 0.00328087339 | < | 0.1 | Pass |
| 21.2 | DMM: Kontrola hodnoty napětí (TP41/TP17,18) | 0.00382429159 | < | 0.1 | Pass |
| 21.3 | DMM: Kontrola hodnoty napětí (TP42/TP17,18) | 3.29205658 | > | 3 | Pass |
| 21.4 | DMM: Kontrola hodnoty napětí (TP43/TP17,18) | 0.00370458066 | < | 0.1 | Pass |
| 21.5 | DMM: Kontrola hodnoty napětí (TP44/TP17,18) | 0.0036429214 | < | 0.1 | Pass |
| 22.1 | DMM: Kontrola hodnoty napětí (TP40/TP17,18) | 0.00080010528 | < | 0.1 | Pass |
| 22.2 | DMM: Kontrola hodnoty napětí (TP41/TP17,18) | 0.00385826807 | < | 0.1 | Pass |
| 22.3 | DMM: Kontrola hodnoty napětí (TP42/TP17,18) | 0.00363039457 | < | 0.1 | Pass |
| 22.4 | DMM: Kontrola hodnoty napětí (TP43/TP17,18) | 3.29197243 | > | 3 | Pass |
| 22.5 | DMM: Kontrola hodnoty napětí (TP44/TP17,18) | 0.00363128034 | < | 0.1 | Pass |
| 23.1 | DMM: Kontrola hodnoty napětí (TP40/TP17,18) | 0.00326902576 | < | 0.1 | Pass |
| 23.2 | Vyhodnocení programu: [updateBin] | [Source: Linet.Tester.Seq.Run. Error: Program č.up | Pass | ||
| 23.2 | DMM: Kontrola hodnoty napětí (TP41/TP17,18) | 0.00378739012 | < | 0.1 | Pass |
| 23.3 | DMM: Kontrola hodnoty napětí (TP42/TP17,18) | 0.00359852004 | < | 0.1 | Pass |
| 23.4 | DMM: Kontrola hodnoty napětí (TP43/TP17,18) | 0.00364342547 | < | 0.1 | Pass |
| 23.5 | DMM: Kontrola hodnoty napětí (TP44/TP17,18) | 3.29195623 | > | 3 | Pass |
| 24.1 | NZ2: Odběr proudu ze zdroje (TP37/TP17,18) | 3.759109E-06 | < | 0.0001 | Pass |
| 24.2 | NZ2: Odběr proudu ze zdroje (TP37/TP17,18) | 0.05082819 | 0.045 | 0.055 | Pass |
| 25.1 | NZ2: Odběr proudu ze zdroje (TP47/TP17,18) | 1.409033E-06 | < | 0.0005 | Pass |
| 25.2 | NZ2: Odběr proudu ze zdroje (TP47/TP17,18) | 0.04994555 | > | 0.04 | Pass |
| 26.1 | NZ2: Odběr proudu ze zdroje (TP45/TP17,18) | 0.009971573 | > | 0.009 | Pass |
| 26.2 | NZ2: Odběr proudu ze zdroje (TP45/TP17,18) | 0.0009174038 | < | 0.002 | Pass |
| 27.1 | NZ2: Kontrola hodnoty proudu (TP46/TP17,18) | 0.009971573 | > | 0.009 | Pass |
| 27.2 | NZ2: Kontrola hodnoty proudu (TP46/TP17,18) | 0.0009125526 | < | 0.002 | Pass |
Measurements over time
Hover for exact values · drag to zoom · double-click to reset
Readings (4)
| Date | Value | Min | Max |
|---|---|---|---|
| 2025-12-09 09:18 | 1949100 | — | — |
| 2025-12-09 09:20 | 1949100 | — | — |
| 2025-12-09 09:53 | 1949100 | — | — |
| 2025-12-09 14:22 | 1949100 | — | — |