Serial 001969056

Tests2
Approved1
Failures1

Tests over time

Test history

DateMeasurement IDID recordArticleResult
2025-11-27 06:43 44817 638998189314206420-2596 S0001055 Fail View
2025-11-27 06:47 44818 638998191921060661-1216 S0001055 Pass View

Test 44817

Result
Fail
Date
2025-11-27 06:43
Article
S0001055
ID record
638998189314206420-2596
ID production
52267
Temperature
25.57
Humidity
27.9
Test duration
52
Error ID
311
Error text
TestSW: [SET_PWM_B][20kHz] vypnout

Measurement lines

StepNameValueMinMaxResult
0.0 Dekódování a uložení načteného SN 001969056 Pass
0.1 Uložení čísla výrobního příkazu 52267 Pass
0.2 Uložení ID obsluhy 1332 Pass
0.3 Uložení teploty okolí 25.57 Pass
0.4 Uložení vlhkosti okolí 27.9 Pass
0.5 Uložení Id testeru (uloženo na lokálním disku) Vez_Hokami_01-v01.01 Pass
0.6 Uložení id Artiklu (produktové číslo) S0001055 Pass
1.1 DMM: Kontrola hodnoty Odporu (TP6/TP4) 0.560714269 < 10 Pass
1.2 DMM: Kontrola hodnoty Odporu (TP6/TP5) 997.05895 800 1200 Pass
3.1 NZ3.1: Měření napětí: Zkrat? 28.00651 > 27.9 Pass
3.2 NZ3.1: Měření proudu: Kontrola odběru 0.002123055 < 0.005 Pass
3.3 R11.12: Zapnutí (TP42/TP43) Pass
3.4 NZ3.1: Měření napětí: Zkrat? 28.00651 > 27.9 Pass
3.5 NZ3.1: Měření proudu: Kontrola odběru 0.02535305 < 0.04 Pass
4.1 DMM: Měření napětí: +BATT (TP49/TP44) 27.9660481 27.9 28.1 Pass
4.2 DMM: Měření napětí: +BATT (TP49/TP34) 27.9959701 27.9 28.1 Pass
4.3 DMM: Měření napětí: +12V (TP49/TP46) 11.8960867 11 12.2 Pass
4.4 DMM: Měření napětí: +5V (TP49/TP7) 5.01540976 4.9 5.1 Pass
4.5 DMM: Měření napětí: +3V3 (TP49/TP16) 3.30752764 3.2 3.4 Pass
4.6 DMM: Měření napětí: VDDA +3V3 (TP49/TP2) 3.30752822 3.2 3.4 Pass
4.7 DMM: Měření napětí: (TP49/TP8) 4.69215594 4.57 4.77 Pass
4.8 DMM: Měření napětí: (TP49/TP9) 4.68994532 4.57 4.77 Pass
4.9 DMM: Měření napětí: (TP49/TP10) 4.6895846 4.57 4.77 Pass
5.1 DMM: Měření napětí: (TP49/TP46) 0.569507528 < 1 Pass
5.2 DMM: Měření napětí: (TP49/TP46) 11.8106353 > 11.5 Pass
6.1 R9.12: Vypnutí (TP49/TP28) Pass
7.1 NZ3: Měření napětí: Zkrat? 28.00651 > 27.9 Pass
7.2 NZ3: Měření proudu: Kontrola odběru 0.02489039 < 0.06 Pass
7.3 R0.6: Zapnutí Ext. Programátoru Pass
8.1 TestSw: Ověření komunikace [TYP:AA NAME:eDrive NAME2:TestSW HW:Kolecko v4 SW: Pass
9.1 TestSW: [CHG_SIG (PC14)] = log1? 16384 16384 16384 Pass
9.2 EL1.1: Ověření proudu na zátěži -> Current? 2.01523 1.6 2.8 Pass
9.3 DMM: Měření napětí: Vstup U14 (TP39/TP32) 29.6481214 29 30.1 Pass
9.4 DMM: Měření napětí: Vstup U14 (TP39/TP33) 11.2867645 10.8 11.5 Pass
9.5 DMM: Měření napětí: Vstup U14 (TP39/TP40) 1.5774032 1.5 1.8 Pass
10.1 NZ3.1: Měření napětí: Zkrat? 28.00651 > 27.9 Pass
10.2 NZ3.1: Měření proudu: Kontrola odběru 0.02574498 < 0.06 Pass
10.3 TestSW: [ADC_PA03] 3844 3667 3937 Pass
12.1 TestSW: [PA15] - napájení sense ABC Pass
12.2 TestSW: [HALL_A (PB4)] = log0? 0 0 0 Pass
12.3 TestSW: [HALL_A (PB4)] = log1? 16 16 16 Pass
12.4 TestSW: [HALL_B (PB5)] = log0? 0 0 0 Pass
12.5 TestSW: [HALL_B (PB5)] = log1? 32 32 32 Pass
12.6 TestSW: [HALL_C (PB0)] = log0? 0 0 0 Pass
12.7 TestSW: [HALL_C (PB0)] = log1? 1 1 1 Pass
13.1 TestSW: [CON_ID (PC13)] = log1? 8192 8192 8192 Pass
13.10 TestSW: [BTN_FFWD][ADC_PA6]? 4082 4000 4096 Pass
13.11 TestSW: [BTN_FFWD][ADC_PA6]? 2036 1900 2100 Pass
13.12 TestSW: [BTN_STOP][ADC_PA5]? 4082 4000 4096 Pass
13.13 TestSW: [BTN_STOP][ADC_PA5]? 2023 1900 2100 Pass
13.2 TestSW: [CON_ID (PC13)] = log0? 0 0 0 Pass
13.3 TestSW: [BTN_DRV][PA11] na log1 Pass
13.4 TestSW: [BTN_FWD][ADC_PB1]? 4082 4000 4096 Pass
13.5 TestSW: [BTN_FWD][ADC_PB1]? 2008 1900 2100 Pass
13.6 TestSW: [BTN_REV][ADC_PA4]? 4082 4000 4096 Pass
13.7 TestSW: [BTN_REV][ADC_PA4]? 2031 1900 2100 Pass
13.8 TestSW: [BTN_ULCK][ADC_PA7]? 4082 4000 4096 Pass
13.9 TestSW: [BTN_ULCK][ADC_PA7]? 2033 1900 2100 Pass
14.1 TestSW: [LED1][PB2] na log1 Pass
14.10 DMM: Měření napětí: LED3 (TP49/TP14) 3.30309739 > 3 Pass
14.11 TestSW: [LED3][PB11] na log0 Pass
14.12 DMM: Měření napětí: LED3 (TP49/TP14) 0.00358415946 < 0.1 Pass
14.13 TestSW: [LED4][PB12] na log1 Pass
14.14 DMM: Měření napětí: LED4 (TP49/TP12) 3.30438232 > 3 Pass
14.15 TestSW: [LED4][PB12] na log0 Pass
14.16 DMM: Měření napětí: LED4 (TP49/TP12) 0.00357002685 < 0.1 Pass
14.2 DMM: Měření napětí: LED1 (TP49/TP13) 3.3029121 > 3 Pass
14.3 TestSW: [LED1][PB2] na log0 Pass
14.4 DMM: Měření napětí: LED1 (TP49/TP13) 0.00372235026 < 0.1 Pass
14.5 TestSW: [LED2][PB10] na log1 Pass
14.6 DMM: Měření napětí: LED1 (TP49/TP11) 3.30311102 > 3 Pass
14.7 TestSW: [LED2][PB10] na log0 Pass
14.8 DMM: Měření napětí: LED1 (TP49/TP11) 0.00357631492 < 0.1 Pass
14.9 TestSW: [LED3][PB11] na log1 Pass
15.1 TestSW: ntc 83 49 90 Pass
16.1 DMM: Měření frekvence (TP49/TP55) 19995.1306 19600 20400 Pass
16.2 DMM: Měření frekvence (TP49/TP56) 19995.1306 19600 20400 Pass
16.3 DMM: Měření napětí (TP49/TP52) 14.0056944 13.3 14.7 Pass
17.1 DMM: Měření frekvence (TP49/TP61) 19995.1249 19600 20400 Pass
17.2 DMM: Měření frekvence (TP49/TP62) 19995.1287 19600 20400 Pass
17.3 DMM: Měření napětí (TP49/TP58) 14.0096434 13.3 14.7 Pass

Measurements over time

Hover for exact values · drag to zoom · double-click to reset

Readings (2)
DateValueMinMax
2025-11-27 06:43 1969056
2025-11-27 06:47 1969056