Testing Portal everyone (auth disabled)

Serial lookup

Search a serial number to see its full test history.

Serial 001969040

Tests6
Approved0
Failures6

Tests over time

Test history

DateMeasurement IDID recordArticleResult
2025-11-27 11:31 44797 638998362519512076-1900 S0001055 Fail View
2025-11-27 11:38 44798 638998366600688553-9382 S0001055 Fail View
2025-11-27 13:32 44799 638998435193155450-7909 S0001055 Fail View
2026-07-09 13:22 77684 639192001033308164-2547 S0001055 Fail View
2026-07-09 14:11 77733 639192030670914268-1516 S0001055 Fail View
2026-07-09 14:39 77742 639192047293840921-5822 S0001055 Fail View

Test 44798

Result
Fail
Date
2025-11-27 11:38
Article
S0001055
ID record
638998366600688553-9382
ID production
52267
Temperature
25.99
Humidity
29.1
Test duration
50
Error ID
315
Error text
DMM: Měření frekvence (TP49/TP67)

Measurement lines

StepNameValueMinMaxResult
0.0 Dekódování a uložení načteného SN 001969040 Pass
0.1 Uložení čísla výrobního příkazu 52267 Pass
0.2 Uložení ID obsluhy 1332 Pass
0.3 Uložení teploty okolí 25.99 Pass
0.4 Uložení vlhkosti okolí 29.1 Pass
0.5 Uložení Id testeru (uloženo na lokálním disku) Vez_Hokami_01-v01.01 Pass
0.6 Uložení id Artiklu (produktové číslo) S0001055 Pass
1.1 DMM: Kontrola hodnoty Odporu (TP6/TP4) 0.591539585 < 10 Pass
1.2 DMM: Kontrola hodnoty Odporu (TP6/TP5) 999.677392 800 1200 Pass
3.1 NZ3.1: Měření napětí: Zkrat? 28.00651 > 27.9 Pass
3.2 NZ3.1: Měření proudu: Kontrola odběru 0.0004256709 < 0.005 Pass
3.3 R11.12: Zapnutí (TP42/TP43) Pass
3.4 NZ3.1: Měření napětí: Zkrat? 28.00651 > 27.9 Pass
3.5 NZ3.1: Měření proudu: Kontrola odběru 0.02406528 < 0.04 Pass
4.1 DMM: Měření napětí: +BATT (TP49/TP44) 27.973264 27.9 28.1 Pass
4.2 DMM: Měření napětí: +BATT (TP49/TP34) 27.9967865 27.9 28.1 Pass
4.3 DMM: Měření napětí: +12V (TP49/TP46) 11.8583332 11 12.2 Pass
4.4 DMM: Měření napětí: +5V (TP49/TP7) 4.97834756 4.9 5.1 Pass
4.5 DMM: Měření napětí: +3V3 (TP49/TP16) 3.30496904 3.2 3.4 Pass
4.6 DMM: Měření napětí: VDDA +3V3 (TP49/TP2) 3.3049587 3.2 3.4 Pass
4.7 DMM: Měření napětí: (TP49/TP8) 4.6597429 4.57 4.77 Pass
4.8 DMM: Měření napětí: (TP49/TP9) 4.65482352 4.57 4.77 Pass
4.9 DMM: Měření napětí: (TP49/TP10) 4.65649024 4.57 4.77 Pass
5.1 DMM: Měření napětí: (TP49/TP46) 0.547304091 < 1 Pass
5.2 DMM: Měření napětí: (TP49/TP46) 11.7730058 > 11.5 Pass
6.1 R9.12: Vypnutí (TP49/TP28) Pass
7.1 NZ3: Měření napětí: Zkrat? 28.00651 > 27.9 Pass
7.2 NZ3: Měření proudu: Kontrola odběru 0.02564477 < 0.06 Pass
7.3 R0.6: Zapnutí Ext. Programátoru Pass
8.1 TestSw: Ověření komunikace [TYP:AA NAME:eDrive NAME2:TestSW HW:Kolecko v4 SW: Pass
9.1 TestSW: [CHG_SIG (PC14)] = log1? 16384 16384 16384 Pass
9.2 EL1.1: Ověření proudu na zátěži -> Current? 2.065733 1.6 2.8 Pass
9.3 DMM: Měření napětí: Vstup U14 (TP39/TP32) 29.6340112 29 30.1 Pass
9.4 DMM: Měření napětí: Vstup U14 (TP39/TP33) 11.2882988 10.8 11.5 Pass
9.5 DMM: Měření napětí: Vstup U14 (TP39/TP40) 1.59959113 1.5 1.8 Pass
10.1 NZ3.1: Měření napětí: Zkrat? 28.00851 > 27.9 Pass
10.2 NZ3.1: Měření proudu: Kontrola odběru 0.02541196 < 0.06 Pass
10.3 TestSW: [ADC_PA03] 3861 3667 3937 Pass
12.1 TestSW: [PA15] - napájení sense ABC Pass
12.2 TestSW: [HALL_A (PB4)] = log0? 0 0 0 Pass
12.3 TestSW: [HALL_A (PB4)] = log1? 16 16 16 Pass
12.4 TestSW: [HALL_B (PB5)] = log0? 0 0 0 Pass
12.5 TestSW: [HALL_B (PB5)] = log1? 32 32 32 Pass
12.6 TestSW: [HALL_C (PB0)] = log0? 0 0 0 Pass
12.7 TestSW: [HALL_C (PB0)] = log1? 1 1 1 Pass
13.1 TestSW: [CON_ID (PC13)] = log1? 8192 8192 8192 Pass
13.10 TestSW: [BTN_FFWD][ADC_PA6]? 4085 4000 4096 Pass
13.11 TestSW: [BTN_FFWD][ADC_PA6]? 2032 1900 2100 Pass
13.12 TestSW: [BTN_STOP][ADC_PA5]? 4085 4000 4096 Pass
13.13 TestSW: [BTN_STOP][ADC_PA5]? 2034 1900 2100 Pass
13.2 TestSW: [CON_ID (PC13)] = log0? 0 0 0 Pass
13.3 TestSW: [BTN_DRV][PA11] na log1 Pass
13.4 TestSW: [BTN_FWD][ADC_PB1]? 4084 4000 4096 Pass
13.5 TestSW: [BTN_FWD][ADC_PB1]? 2011 1900 2100 Pass
13.6 TestSW: [BTN_REV][ADC_PA4]? 4085 4000 4096 Pass
13.7 TestSW: [BTN_REV][ADC_PA4]? 2036 1900 2100 Pass
13.8 TestSW: [BTN_ULCK][ADC_PA7]? 4085 4000 4096 Pass
13.9 TestSW: [BTN_ULCK][ADC_PA7]? 2034 1900 2100 Pass
14.1 TestSW: [LED1][PB2] na log1 Pass
14.10 DMM: Měření napětí: LED3 (TP49/TP14) 3.30014592 > 3 Pass
14.11 TestSW: [LED3][PB11] na log0 Pass
14.12 DMM: Měření napětí: LED3 (TP49/TP14) 0.00352836028 < 0.1 Pass
14.13 TestSW: [LED4][PB12] na log1 Pass
14.14 DMM: Měření napětí: LED4 (TP49/TP12) 3.30138577 > 3 Pass
14.15 TestSW: [LED4][PB12] na log0 Pass
14.16 DMM: Měření napětí: LED4 (TP49/TP12) 0.00350307765 < 0.1 Pass
14.2 DMM: Měření napětí: LED1 (TP49/TP13) 3.29997652 > 3 Pass
14.3 TestSW: [LED1][PB2] na log0 Pass
14.4 DMM: Měření napětí: LED1 (TP49/TP13) 0.00367700614 < 0.1 Pass
14.5 TestSW: [LED2][PB10] na log1 Pass
14.6 DMM: Měření napětí: LED1 (TP49/TP11) 3.30014568 > 3 Pass
14.7 TestSW: [LED2][PB10] na log0 Pass
14.8 DMM: Měření napětí: LED1 (TP49/TP11) 0.00354063521 < 0.1 Pass
14.9 TestSW: [LED3][PB11] na log1 Pass
15.1 TestSW: ntc 78 49 90 Pass
16.1 DMM: Měření frekvence (TP49/TP55) 19995.1574 19600 20400 Pass
16.2 DMM: Měření frekvence (TP49/TP56) 19995.155 19600 20400 Pass
16.3 DMM: Měření napětí (TP49/TP52) 14.0042133 13.3 14.7 Pass
17.1 DMM: Měření frekvence (TP49/TP61) 19995.1536 19600 20400 Pass
17.2 DMM: Měření frekvence (TP49/TP62) 19995.155 19600 20400 Pass
17.3 DMM: Měření napětí (TP49/TP58) 14.003661 13.3 14.7 Pass
18.1 DMM: Měření frekvence (TP49/TP67) 49.9978967 19600 20400 Fail

Measurements over time

Hover for exact values · drag to zoom · double-click to reset

Readings (3)
DateValueMinMax
2026-07-09 13:22 0.998 10
2026-07-09 14:11 0.971 10
2026-07-09 14:39 0.984 10