Testing Portal everyone (auth disabled)

Serial lookup

Search a serial number to see its full test history.

Serial 001968866

Tests2
Approved1
Failures1

Tests over time

Test history

DateMeasurement IDID recordArticleResult
2025-11-27 09:42 44670 638998297182028073-7331 S0001055 Fail View
2025-11-27 10:32 44671 638998326577794376-6973 S0001055 Pass View

Test 44670

Result
Fail
Date
2025-11-27 09:42
Article
S0001055
ID record
638998297182028073-7331
ID production
52267
Temperature
26.16
Humidity
29.39
Test duration
55
Error ID
356
Error text
EL1.2: Ověření proudu na zátěži -> Current?

Measurement lines

StepNameValueMinMaxResult
0.0 Dekódování a uložení načteného SN 001968866 Pass
0.1 Uložení čísla výrobního příkazu 52267 Pass
0.2 Uložení ID obsluhy 1332 Pass
0.3 Uložení teploty okolí 26.16 Pass
0.4 Uložení vlhkosti okolí 29.39 Pass
0.5 Uložení Id testeru (uloženo na lokálním disku) Vez_Hokami_01-v01.01 Pass
0.6 Uložení id Artiklu (produktové číslo) S0001055 Pass
1.1 DMM: Kontrola hodnoty Odporu (TP6/TP4) 0.77172564 < 10 Pass
1.2 DMM: Kontrola hodnoty Odporu (TP6/TP5) 997.990647 800 1200 Pass
3.1 NZ3.1: Měření napětí: Zkrat? 28.00851 > 27.9 Pass
3.2 NZ3.1: Měření proudu: Kontrola odběru 0.001851945 < 0.005 Pass
3.3 R11.12: Zapnutí (TP42/TP43) Pass
3.4 NZ3.1: Měření napětí: Zkrat? 28.00651 > 27.9 Pass
3.5 NZ3.1: Měření proudu: Kontrola odběru 0.02506131 < 0.04 Pass
4.1 DMM: Měření napětí: +BATT (TP49/TP44) 27.9480249 27.9 28.1 Pass
4.2 DMM: Měření napětí: +BATT (TP49/TP34) 27.9947562 27.9 28.1 Pass
4.3 DMM: Měření napětí: +12V (TP49/TP46) 11.8404127 11 12.2 Pass
4.4 DMM: Měření napětí: +5V (TP49/TP7) 4.9880996 4.9 5.1 Pass
4.5 DMM: Měření napětí: +3V3 (TP49/TP16) 3.30108211 3.2 3.4 Pass
4.6 DMM: Měření napětí: VDDA +3V3 (TP49/TP2) 3.30110581 3.2 3.4 Pass
4.7 DMM: Měření napětí: (TP49/TP8) 4.66798138 4.57 4.77 Pass
4.8 DMM: Měření napětí: (TP49/TP9) 4.66367323 4.57 4.77 Pass
4.9 DMM: Měření napětí: (TP49/TP10) 4.66429301 4.57 4.77 Pass
5.1 DMM: Měření napětí: (TP49/TP46) 0.568368759 < 1 Pass
5.2 DMM: Měření napětí: (TP49/TP46) 11.7550155 > 11.5 Pass
6.1 R9.12: Vypnutí (TP49/TP28) Pass
7.1 NZ3: Měření napětí: Zkrat? 28.00851 > 27.9 Pass
7.2 NZ3: Měření proudu: Kontrola odběru 0.02476368 < 0.06 Pass
7.3 R0.6: Zapnutí Ext. Programátoru Pass
8.1 TestSw: Ověření komunikace [TYP:AA NAME:eDrive NAME2:TestSW HW:Kolecko v4 SW: Pass
9.1 TestSW: [CHG_SIG (PC14)] = log1? 16384 16384 16384 Pass
9.2 EL1.1: Ověření proudu na zátěži -> Current? 2.082401 1.6 2.8 Pass
9.3 DMM: Měření napětí: Vstup U14 (TP39/TP32) 29.6306244 29 30.1 Pass
9.4 DMM: Měření napětí: Vstup U14 (TP39/TP33) 11.2889841 10.8 11.5 Pass
9.5 DMM: Měření napětí: Vstup U14 (TP39/TP40) 1.60711408 1.5 1.8 Pass
10.1 NZ3.1: Měření napětí: Zkrat? 28.00851 > 27.9 Pass
10.2 NZ3.1: Měření proudu: Kontrola odběru 0.02565658 < 0.06 Pass
10.3 TestSW: [ADC_PA03] 3830 3667 3937 Pass
12.1 TestSW: [PA15] - napájení sense ABC Pass
12.2 TestSW: [HALL_A (PB4)] = log0? 0 0 0 Pass
12.3 TestSW: [HALL_A (PB4)] = log1? 16 16 16 Pass
12.4 TestSW: [HALL_B (PB5)] = log0? 0 0 0 Pass
12.5 TestSW: [HALL_B (PB5)] = log1? 32 32 32 Pass
12.6 TestSW: [HALL_C (PB0)] = log0? 0 0 0 Pass
12.7 TestSW: [HALL_C (PB0)] = log1? 1 1 1 Pass
13.1 TestSW: [CON_ID (PC13)] = log1? 8192 8192 8192 Pass
13.10 TestSW: [BTN_FFWD][ADC_PA6]? 4085 4000 4096 Pass
13.11 TestSW: [BTN_FFWD][ADC_PA6]? 2034 1900 2100 Pass
13.12 TestSW: [BTN_STOP][ADC_PA5]? 4085 4000 4096 Pass
13.13 TestSW: [BTN_STOP][ADC_PA5]? 2025 1900 2100 Pass
13.2 TestSW: [CON_ID (PC13)] = log0? 0 0 0 Pass
13.3 TestSW: [BTN_DRV][PA11] na log1 Pass
13.4 TestSW: [BTN_FWD][ADC_PB1]? 4084 4000 4096 Pass
13.5 TestSW: [BTN_FWD][ADC_PB1]? 2006 1900 2100 Pass
13.6 TestSW: [BTN_REV][ADC_PA4]? 4085 4000 4096 Pass
13.7 TestSW: [BTN_REV][ADC_PA4]? 2030 1900 2100 Pass
13.8 TestSW: [BTN_ULCK][ADC_PA7]? 4085 4000 4096 Pass
13.9 TestSW: [BTN_ULCK][ADC_PA7]? 2036 1900 2100 Pass
14.1 TestSW: [LED1][PB2] na log1 Pass
14.10 DMM: Měření napětí: LED3 (TP49/TP14) 3.2969883 > 3 Pass
14.11 TestSW: [LED3][PB11] na log0 Pass
14.12 DMM: Měření napětí: LED3 (TP49/TP14) 0.00354543944 < 0.1 Pass
14.13 TestSW: [LED4][PB12] na log1 Pass
14.14 DMM: Měření napětí: LED4 (TP49/TP12) 3.29830666 > 3 Pass
14.15 TestSW: [LED4][PB12] na log0 Pass
14.16 DMM: Měření napětí: LED4 (TP49/TP12) 0.00351345794 < 0.1 Pass
14.2 DMM: Měření napětí: LED1 (TP49/TP13) 3.29672475 > 3 Pass
14.3 TestSW: [LED1][PB2] na log0 Pass
14.4 DMM: Měření napětí: LED1 (TP49/TP13) 0.0036979718 < 0.1 Pass
14.5 TestSW: [LED2][PB10] na log1 Pass
14.6 DMM: Měření napětí: LED1 (TP49/TP11) 3.2969192 > 3 Pass
14.7 TestSW: [LED2][PB10] na log0 Pass
14.8 DMM: Měření napětí: LED1 (TP49/TP11) 0.00355858172 < 0.1 Pass
14.9 TestSW: [LED3][PB11] na log1 Pass
15.1 TestSW: ntc 79 49 90 Pass
16.1 DMM: Měření frekvence (TP49/TP55) 19995.1927 19600 20400 Pass
16.2 DMM: Měření frekvence (TP49/TP56) 19995.1908 19600 20400 Pass
16.3 DMM: Měření napětí (TP49/TP52) 14.0058063 13.3 14.7 Pass
17.1 DMM: Měření frekvence (TP49/TP61) 19995.1871 19600 20400 Pass
17.2 DMM: Měření frekvence (TP49/TP62) 19995.1908 19600 20400 Pass
17.3 DMM: Měření napětí (TP49/TP58) 14.0047764 13.3 14.7 Pass
18.1 DMM: Měření frekvence (TP49/TP67) 19995.1852 19600 20400 Pass
18.2 DMM: Měření frekvence (TP49/TP68) 19995.1894 19600 20400 Pass
18.3 DMM: Měření napětí (TP49/TP58) 14.0057958 13.3 14.7 Pass
19.1 DMM: Měření napětí: +5V (TP49/TP7) -0.000661653537 < 0.5 Pass
20.0.1 TestSW: [ADC_PA0] sense A do var VA = 2268 Pass
20.0.2 TestSW: [ADC_PA1] sense B do var VB = 2261 Pass
20.0.3 TestSW: [ADC_PA2] sense C do var VC = 2263 Pass
20.0.5 Analysis: VA VA[2268] 2210 2340 Pass
20.0.6 Analysis: VB VB[2261] 2210 2340 Pass
20.0.7 Analysis: VC VC[2263] 2210 2340 Pass
20.1 NZ3.1: Měření napětí: Zkrat? 28.00851 > 27.9 Pass
20.1.1 EL1.2: Ověření proudu na zátěži -> Current? -0.0010706 4.7 5.3 Fail
20.2 NZ3.1: Měření proudu: Kontrola odběru 0.03846945 < 0.06 Pass

Measurements over time

Hover for exact values · drag to zoom · double-click to reset

Readings (2)
DateValueMinMax
2025-11-27 09:42 1968866
2025-11-27 10:32 1968866