Serial 001607627
Tests2
Approved1
Failures1
Tests over time
Test history
| Date | Measurement ID | ID record | Article | Result | |
|---|---|---|---|---|---|
| 2025-11-20 11:41 | 43875 | 638992319865100431-2947 | S0004028 | Fail | View |
| 2025-11-20 11:42 | 43876 | 638992321165274153-4092 | S0004028 | Pass | View |
Test 43876
- Result
- Pass
- Date
- 2025-11-20 11:42
- Article
- S0004028
- ID record
- 638992321165274153-4092
- ID production
- 52061
- Temperature
- 25.36
- Humidity
- 29.47
- Test duration
- 59
- Error ID
- —
- Error text
- —
Measurement lines
| Step | Name | Value | Min | Max | Result |
|---|---|---|---|---|---|
| 0.0 | Dekódování a uložení načteného SN | 001607627 | Pass | ||
| 0.1 | Uložení čísla výrobního příkazu | 52061 | Pass | ||
| 0.2 | Uložení ID obsluhy | 1358 | Pass | ||
| 0.3 | Uložení teploty okolí | 25.36 | Pass | ||
| 0.4 | Uložení vlhkosti okolí | 29.47 | Pass | ||
| 0.5 | Uložení Id testeru (uloženo na lokálním disku) | Vez_Hokami_01-v01.01 | Pass | ||
| 0.6 | Uložení id Artiklu (produktové číslo) | S0004028 | Pass | ||
| 1.1 | DMM: Kontrola hodnoty Odporu (TP2/TP3) | 999.880851 | 900 | 1100 | Pass |
| 1.2 | DMM: Kontrola hodnoty Odporu (TP4/TP3) | 3308.89515 | 3200 | 3400 | Pass |
| 1.3 | DMM: Kontrola hodnoty Odporu (TP48/TP25,26) | 998.238969 | 900 | 1100 | Pass |
| 1.4 | DMM: Kontrola hodnoty Odporu (TP13/TP25,26) | 10092.4412 | 9500 | 10500 | Pass |
| 2.1 | DMM: Kontrola hodnoty Odporu (TP36/TP37) | 1069.80957 | 1012 | 1120 | Pass |
| 2.2 | DMM: Kontrola hodnoty Odporu (TP40/TP41) | 1040.36412 | 1012 | 1120 | Pass |
| 4.0 | DMM: Kontrola hodnoty napětí (TP22/TP25,26) | -0.730764245 | -0.75 | -0.65 | Pass |
| 4.1 | NZ1: Odběr proudu ze zdroje (TP25/TP25,26) | 0.01001955 | 0.009 | 1 | Pass |
| 5.1 | NZ1: Odběr proudu ze zdroje (TP22/TP25,26) | 0.03173487 | 0.025 | 0.035 | Pass |
| 5.2 | DMM: Kontrola hodnoty napětí (TP49/TP25,26) | 8.75224962 | 8.7 | 9 | Pass |
| 5.3 | DMM: Kontrola hodnoty napětí (TP17/TP25,26) | 4.97280706 | 4.9 | 5.1 | Pass |
| 5.4 | DMM: Kontrola hodnoty napětí (TP16/TP25,26) | 4.99602416 | 4.9 | 5.1 | Pass |
| 5.5 | DMM: Kontrola hodnoty napětí (TP29/TP25,26) | 4.99589863 | 4.9 | 5.1 | Pass |
| 5.6 | DMM: Kontrola hodnoty napětí (TP14/TP25,26) | 3.30813411 | 3.2 | 3.4 | Pass |
| 5.7 | DMM: Kontrola hodnoty napětí (TP5/TP25,26) | 3.3080448 | 3.2 | 3.4 | Pass |
| 5.8 | DMM: Kontrola hodnoty napětí (TP24/TP25,26) | 8.6689657 | 7.5 | 9 | Pass |
| 5.9 | DMM: Kontrola hodnoty napětí (TP20/TP25,26) | 0.18345347 | 0 | 0.65 | Pass |
| 6.1 | NZ1: Odběr proudu ze zdroje (TP25,26/TP19) | 2.723677E-05 | -0.0001 | 0.0001 | Pass |
| 6.2 | DMM: Kontrola hodnoty napětí (TP20/TP25,26) | 0.159396964 | -0.2 | 0.5 | Pass |
| 6.3 | NZ1: Odběr proudu ze zdroje (TP25,26/TP19) | 0.01997921 | 0.019 | 1 | Pass |
| 7.1 | NZ1: Odběr proudu ze zdroje (TP19/TP25,26) | 0.001268112 | < | 0.0001 | Fail |
| 7.1 | NZ1: Odběr proudu ze zdroje (TP19/TP25,26) | 9.2546E-05 | < | 0.0001 | Pass |
| 7.2 | DMM: Kontrola hodnoty napětí (TP20/TP25,26) | 6.00222383 | 5.95 | 7 | Pass |
| 7.3 | DMM: Kontrola hodnoty napětí (TP50/TP25,26) | 3.14814184 | > | 3 | Pass |
| 7.4 | DMM: Kontrola hodnoty napětí (TP15/TP25,26) | 0.083316267 | 0 | 0.5 | Pass |
| 7.5 | NZ1: Odběr proudu ze zdroje (TP19/TP25,26) | 0.0006476745 | 0.00057 | 0.0007 | Pass |
| 7.6 | NZ2: Odběr proudu ze zdroje (TP42/TP25,26) | 0.0001844339 | -0.001 | 0.0002 | Pass |
| 7.7 | NZ1: Odběr proudu ze zdroje (TP19/TP25,26) | 5.989139E-05 | -0.001 | 0.0001 | Pass |
| 7.8 | DMM: Kontrola hodnoty napětí (TP38/TP25,26) | 8.9526551 | 8.7 | 9 | Pass |
| 9.0 | NZ1: Odběr proudu ze zdroje (TP22/TP25,26) | 0.04094347 | 0 | 0.099 | Pass |
| 9.1 | Vyhodnocení programu: [testSW] | Running... | Fail | ||
| 9.1 | Vyhodnocení programu: [testSW] | 0 | Pass | ||
| 10.2 | NZ1: Odběr proudu ze zdroje (TP19/DLO) | 9.2546E-05 | -0.001 | 0.0002 | Pass |
| 10.3 | NZ2: Odběr proudu ze zdroje (TP42/TP25,26) | 0.0001650619 | -0.001 | 0.0002 | Pass |
| 10.4 | NZ1: Odběr proudu ze zdroje (TP19/DLO) | 0.02317936 | 0.015 | 0.03 | Pass |
| 11.1 | DMM: Kontrola hodnoty proudu (TP25,26/NZ1-) | 0.140830116 | 0.13 | 1 | Pass |
| 11.2 | NZ1: Odběr proudu ze zdroje (TP19/DLO) | 0.02575907 | 0.015 | 0.03 | Pass |
| 12.1 | NZ2: Odběr proudu ze zdroje (TP22/TP25,26) | 0.04249211 | 0.02 | 0.05 | Pass |
| 12.2 | NZ1: Odběr proudu ze zdroje (TP19/DLO) | 5.989139E-05 | -0.001 | 0.0001 | Pass |
| 12.3 | NZ1: Odběr proudu ze zdroje (TP19/DLO) | 0.02213441 | 0.015 | 0.03 | Pass |
| 13.1 | NZ1: Odběr proudu ze zdroje (TP19/DLO) | 5.989139E-05 | -0.001 | 0.0001 | Pass |
| 14.1 | NZ1: Odběr proudu ze zdroje (TP22/TP25,26) | 0.04564574 | 0.03 | 0.06 | Pass |
| 15.1 | Test oscilátorů | 0 (0x00) | 0 (0x00) | 0 (0x00) | Pass |
| 16.1 | Test komunikace mezi U2 a U3 přes RS485 | 0 (0x00) | 0 (0x00) | 0 (0x00) | Pass |
| 17.1 | Test eeprom a ověření velikosti | 0 (0x00) | 0 (0x00) | 0 (0x00) | Pass |
| 17.2 | Test SPI FLASH | 0 (0x00) | 0 (0x00) | 255 (0xff) | Pass |
| 18.1 | Analysis: hodnota na max | True | d_VCC_ADC[3404]<=d_max[3433.50516132299] | Pass | |
| 19.1 | Analysis: hodnota na max | True | d_U5V_ADC[3100]<=d_max[3116.41567804446] | Pass | |
| 19.1 | NZ2: Odběr proudu ze zdroje (TP19/TP25,26) | 0.0002911059 | < | 0.0001 | Fail |
| 19.1 | NZ2: Odběr proudu ze zdroje (TP19/TP25,26) | 9.960501E-05 | < | 0.0001 | Pass |
| 19.2 | DMM: Změřit napětí VBATT a uložit (TP20/TP25,26) | VarDouble: d_VBATT = 5.9904576900000004 | Pass | ||
| 19.3 | Analysis: hodnota na max | True | d_VBATT_ADC[2316]<=d_max[2344.8730393225] | Pass | |
| 20.1 | NZ2: Odběr proudu ze zdroje (TP42/TP25,26) | 0.00191191 | -0.0001 | 0.005 | Pass |
| 20.2 | Přečti hodnotu PA4[HW_CH_DET] | 0 | 0 | 0 | Pass |
| 20.3 | DMM: Kontrola hodnoty napětí (TP38/TP25,26) | 0.0231603741 | 0 | 0.49 | Pass |
| 20.4 | DMM: Kontrola hodnoty napětí (TP38/TP25,26) | 11.940826 | 11.7 | 15 | Pass |
| 21.1 | NZ2: Odběr proudu ze zdroje (TP39/TP25,26) | 3.432907E-05 | -0.0001 | 0.001 | Pass |
| 21.2 | DMM: Kontrola hodnoty napětí (TP43/TP25,26) | 11.9065616 | 11.7 | 15 | Pass |
| 22.2 | DMM: Kontrola hodnoty proudu (TP7/R15R) | 0.256382908 | 0.2425 | 0.2775 | Pass |
| 22.2 | DMM: Kontrola hodnoty proudu (TP7/R15R) | 0 | -0.0005 | 0.0005 | Pass |
| 23.1 | Test proměnné FREQ, jestli je v intervalu | FREQ[4095.92420771933] | 4094 | 4097 | Pass |
| 23.2 | Vyhodnocení programu: [updateBin] | 0 | Pass | ||
| 25.1 | NZ2: Odběr proudu ze zdroje (TP45/TP25,26) | 0.1998774 | > | 0.195 | Pass |
| 26.1 | NZ2: Odběr proudu ze zdroje (TP44/TP25,26) | 0.1998774 | > | 0.195 | Pass |
| 27.1 | NZ2: Odběr proudu ze zdroje (TP46/TP25,26) | 0.1998774 | > | 0.195 | Pass |
| 28.1 | NZ2: Odběr proudu ze zdroje (TP47/TP25,26) | 0.1998774 | > | 0.195 | Pass |
| 29.1 | Změřit ADC U11 AIN7, AIN8 | 8811 | 8400 | 10000 | Pass |
| 30.1 | Změřit ADC U11 AIN5, AIN6 | 8823 | 8400 | 10000 | Pass |
| 31.1 | Změřit ADC U11 AIN3, AIN4 | 8826 | 8400 | 10000 | Pass |
| 32.1 | Změřit ADC U11 AIN1, AIN2 | 8775 | 8400 | 10000 | Pass |
| 35.1 | Vyhodnocení programu: [finalSW] | Running... | Fail | ||
| 35.1 | Vyhodnocení programu: [finalSW] | 0 | Pass |
Measurements over time
Hover for exact values · drag to zoom · double-click to reset
Readings (2)
| Date | Value | Min | Max |
|---|---|---|---|
| 2025-11-20 11:41 | 1607627 | — | — |
| 2025-11-20 11:42 | 1607627 | — | — |