Serial lookup
Search a serial number to see its full test history.
Serial 001607283
Tests2
Approved1
Failures1
Tests over time
Test history
| Date | Measurement ID | ID record | Article | Result | |
|---|---|---|---|---|---|
| 2025-11-20 18:54 | 43520 | 638992579773058570-6360 | S0004028 | Fail | View |
| 2025-11-20 18:56 | 43521 | 638992580955362423-7042 | S0004028 | Pass | View |
Test 43521
- Result
- Pass
- Date
- 2025-11-20 18:56
- Article
- S0004028
- ID record
- 638992580955362423-7042
- ID production
- 52061
- Temperature
- 25.49
- Humidity
- 28.97
- Test duration
- 68
- Error ID
- —
- Error text
- —
Measurement lines
| Step | Name | Value | Min | Max | Result |
|---|---|---|---|---|---|
| 0.0 | Dekódování a uložení načteného SN | 001607283 | Pass | ||
| 0.1 | Uložení čísla výrobního příkazu | 52061 | Pass | ||
| 0.2 | Uložení ID obsluhy | 0043 | Pass | ||
| 0.3 | Uložení teploty okolí | 25.49 | Pass | ||
| 0.4 | Uložení vlhkosti okolí | 28.97 | Pass | ||
| 0.5 | Uložení Id testeru (uloženo na lokálním disku) | Vez_Hokami_01-v01.01 | Pass | ||
| 0.6 | Uložení id Artiklu (produktové číslo) | S0004028 | Pass | ||
| 1.1 | DMM: Kontrola hodnoty Odporu (TP2/TP3) | 1004.75541 | 900 | 1100 | Pass |
| 1.2 | DMM: Kontrola hodnoty Odporu (TP4/TP3) | 3310.86185 | 3200 | 3400 | Pass |
| 1.3 | DMM: Kontrola hodnoty Odporu (TP48/TP25,26) | 1002.17515 | 900 | 1100 | Pass |
| 1.4 | DMM: Kontrola hodnoty Odporu (TP13/TP25,26) | 10036.0882 | 9500 | 10500 | Pass |
| 2.1 | DMM: Kontrola hodnoty Odporu (TP36/TP37) | 1064.26069 | 1012 | 1120 | Pass |
| 2.2 | DMM: Kontrola hodnoty Odporu (TP40/TP41) | 1033.41644 | 1012 | 1120 | Pass |
| 4.0 | DMM: Kontrola hodnoty napětí (TP22/TP25,26) | -0.729036524 | -0.75 | -0.65 | Pass |
| 4.1 | NZ1: Odběr proudu ze zdroje (TP25/TP25,26) | 0.009986895 | 0.009 | 1 | Pass |
| 5.1 | NZ1: Odběr proudu ze zdroje (TP22/TP25,26) | 0.03163691 | 0.025 | 0.035 | Pass |
| 5.2 | DMM: Kontrola hodnoty napětí (TP49/TP25,26) | 8.75634 | 8.7 | 9 | Pass |
| 5.3 | DMM: Kontrola hodnoty napětí (TP17/TP25,26) | 4.9901597 | 4.9 | 5.1 | Pass |
| 5.4 | DMM: Kontrola hodnoty napětí (TP16/TP25,26) | 5.00495779 | 4.9 | 5.1 | Pass |
| 5.5 | DMM: Kontrola hodnoty napětí (TP29/TP25,26) | 5.00494918 | 4.9 | 5.1 | Pass |
| 5.6 | DMM: Kontrola hodnoty napětí (TP14/TP25,26) | 3.30048426 | 3.2 | 3.4 | Pass |
| 5.7 | DMM: Kontrola hodnoty napětí (TP5/TP25,26) | 3.30038114 | 3.2 | 3.4 | Pass |
| 5.8 | DMM: Kontrola hodnoty napětí (TP24/TP25,26) | 8.67387934 | 7.5 | 9 | Pass |
| 5.9 | DMM: Kontrola hodnoty napětí (TP20/TP25,26) | 0.203759619 | 0 | 0.65 | Pass |
| 6.1 | NZ1: Odběr proudu ze zdroje (TP25,26/TP19) | 2.723677E-05 | -0.0001 | 0.0001 | Pass |
| 6.2 | DMM: Kontrola hodnoty napětí (TP20/TP25,26) | 0.171353036 | -0.2 | 0.5 | Pass |
| 6.3 | NZ1: Odběr proudu ze zdroje (TP25,26/TP19) | 0.01997921 | 0.019 | 1 | Pass |
| 7.1 | NZ1: Odběr proudu ze zdroje (TP19/TP25,26) | 0.001431385 | < | 0.0001 | Fail |
| 7.1 | NZ1: Odběr proudu ze zdroje (TP19/TP25,26) | 9.2546E-05 | < | 0.0001 | Pass |
| 7.2 | DMM: Kontrola hodnoty napětí (TP20/TP25,26) | 6.0021771 | 5.95 | 7 | Pass |
| 7.3 | DMM: Kontrola hodnoty napětí (TP50/TP25,26) | 3.14296808 | > | 3 | Pass |
| 7.4 | DMM: Kontrola hodnoty napětí (TP15/TP25,26) | 0.0532741772 | 0 | 0.5 | Pass |
| 7.5 | NZ1: Odběr proudu ze zdroje (TP19/TP25,26) | 0.0006476745 | 0.00057 | 0.0007 | Pass |
| 7.6 | NZ2: Odběr proudu ze zdroje (TP42/TP25,26) | 0.0001070434 | -0.001 | 0.0002 | Pass |
| 7.7 | NZ1: Odběr proudu ze zdroje (TP19/TP25,26) | 9.2546E-05 | -0.001 | 0.0001 | Pass |
| 7.8 | DMM: Kontrola hodnoty napětí (TP38/TP25,26) | 8.95370101 | 8.7 | 9 | Pass |
| 9.0 | NZ1: Odběr proudu ze zdroje (TP22/TP25,26) | 0.04061693 | 0 | 0.099 | Pass |
| 9.1 | Vyhodnocení programu: [testSW] | Running... | Fail | ||
| 9.1 | Vyhodnocení programu: [testSW] | 0 | Pass | ||
| 10.2 | NZ1: Odběr proudu ze zdroje (TP19/DLO) | 9.2546E-05 | -0.001 | 0.0002 | Pass |
| 10.3 | NZ2: Odběr proudu ze zdroje (TP42/TP25,26) | 9.428058E-05 | -0.001 | 0.0002 | Pass |
| 10.4 | NZ1: Odběr proudu ze zdroje (TP19/DLO) | 0.0266081 | 0.015 | 0.03 | Pass |
| 11.1 | DMM: Kontrola hodnoty proudu (TP25,26/NZ1-) | 0.142332804 | 0.13 | 1 | Pass |
| 11.2 | NZ1: Odběr proudu ze zdroje (TP19/DLO) | 0.02579173 | 0.015 | 0.03 | Pass |
| 12.1 | NZ2: Odběr proudu ze zdroje (TP22/TP25,26) | 0.04058952 | 0.02 | 0.05 | Pass |
| 12.2 | NZ1: Odběr proudu ze zdroje (TP19/DLO) | 9.2546E-05 | -0.001 | 0.0001 | Pass |
| 12.3 | NZ1: Odběr proudu ze zdroje (TP19/DLO) | 0.02543253 | 0.015 | 0.03 | Pass |
| 13.1 | NZ1: Odběr proudu ze zdroje (TP19/DLO) | 5.989139E-05 | -0.001 | 0.0001 | Pass |
| 14.1 | NZ1: Odběr proudu ze zdroje (TP22/TP25,26) | 0.04531919 | 0.03 | 0.06 | Pass |
| 15.1 | Test oscilátorů | 0 (0x00) | 0 (0x00) | 0 (0x00) | Pass |
| 16.1 | Test komunikace mezi U2 a U3 přes RS485 | 0 (0x00) | 0 (0x00) | 0 (0x00) | Pass |
| 17.1 | Test eeprom a ověření velikosti | 0 (0x00) | 0 (0x00) | 0 (0x00) | Pass |
| 17.2 | Test SPI FLASH | 0 (0x00) | 0 (0x00) | 255 (0xff) | Pass |
| 18.1 | Analysis: hodnota na max | True | d_VCC_ADC[3383]<=d_max[3443.98142958669] | Pass | |
| 19.1 | Analysis: hodnota na max | True | d_U5V_ADC[3113]<=d_max[3129.31682540269] | Pass | |
| 19.1 | NZ2: Odběr proudu ze zdroje (TP19/TP25,26) | 0.0002007246 | < | 0.0001 | Fail |
| 19.1 | NZ2: Odběr proudu ze zdroje (TP19/TP25,26) | 9.560038E-05 | < | 0.0001 | Pass |
| 19.2 | DMM: Změřit napětí VBATT a uložit (TP20/TP25,26) | VarDouble: d_VBATT = 5.9905797500000002 | Pass | ||
| 19.3 | Analysis: hodnota na max | True | d_VBATT_ADC[2332]<=d_max[2350.6108318495] | Pass | |
| 20.1 | NZ2: Odběr proudu ze zdroje (TP42/TP25,26) | 0.0002651547 | -0.0001 | 0.005 | Pass |
| 20.2 | Přečti hodnotu PA4[HW_CH_DET] | 0 | 0 | 0 | Pass |
| 20.3 | DMM: Kontrola hodnoty napětí (TP38/TP25,26) | 0.0429353928 | 0 | 0.49 | Pass |
| 20.4 | DMM: Kontrola hodnoty napětí (TP38/TP25,26) | 11.9434194 | 11.7 | 15 | Pass |
| 21.1 | NZ2: Odběr proudu ze zdroje (TP39/TP25,26) | 3.500434E-06 | -0.0001 | 0.001 | Pass |
| 21.2 | DMM: Kontrola hodnoty napětí (TP43/TP25,26) | 11.9071231 | 11.7 | 15 | Pass |
| 22.2 | DMM: Kontrola hodnoty proudu (TP7/R15R) | 0.251772061 | 0.2425 | 0.2775 | Pass |
| 22.2 | DMM: Kontrola hodnoty proudu (TP7/R15R) | 0 | -0.0005 | 0.0005 | Pass |
| 23.1 | Test proměnné FREQ, jestli je v intervalu | FREQ[4095.91518592819] | 4094 | 4097 | Pass |
| 23.2 | Vyhodnocení programu: [updateBin] | 0 | Pass | ||
| 25.1 | NZ2: Odběr proudu ze zdroje (TP45/TP25,26) | 0.1998774 | > | 0.195 | Pass |
| 26.1 | NZ2: Odběr proudu ze zdroje (TP44/TP25,26) | 0.1998774 | > | 0.195 | Pass |
| 27.1 | NZ2: Odběr proudu ze zdroje (TP46/TP25,26) | 0.1998774 | > | 0.195 | Pass |
| 28.1 | NZ2: Odběr proudu ze zdroje (TP47/TP25,26) | 0.1998774 | > | 0.195 | Pass |
| 29.1 | Změřit ADC U11 AIN7, AIN8 | 8812 | 8400 | 10000 | Pass |
| 30.1 | Změřit ADC U11 AIN5, AIN6 | 8837 | 8400 | 10000 | Pass |
| 31.1 | Změřit ADC U11 AIN3, AIN4 | 8836 | 8400 | 10000 | Pass |
| 32.1 | Změřit ADC U11 AIN1, AIN2 | 8829 | 8400 | 10000 | Pass |
| 35.1 | Vyhodnocení programu: [finalSW] | Running... | Fail | ||
| 35.1 | Vyhodnocení programu: [finalSW] | 0 | Pass |
Measurements over time
Hover for exact values · drag to zoom · double-click to reset
Readings (2)
| Date | Value | Min | Max |
|---|---|---|---|
| 2025-11-20 18:54 | 1607283 | — | — |
| 2025-11-20 18:56 | 1607283 | — | — |