| Date | Measurement ID | ID record | Article | Result | |
|---|---|---|---|---|---|
| 2024-11-26 16:59 | 4321 | 638682335270425026-6064 | S0000174 | Fail | View |
| 2024-11-26 17:04 | 4322 | 638682338059152685-9299 | S0000174 | Pass | View |
| 2024-11-27 07:39 | 4359 | 638682863607580716-5454 | S0000174 | Fail | View |
| 2024-11-27 07:41 | 4360 | 638682864050372497-5794 | S0000174 | Pass | View |
Test 4321
- Result
- Fail
- Date
- 2024-11-26 16:59
- Article
- S0000174
- ID record
- 638682335270425026-6064
- ID production
- 50930
- Temperature
- 25,92
- Humidity
- 33,46
- Test duration
- 37
- Error ID
- 328
- Error text
- NZ2: Odběr proudu ze zdroje (TP19/TP25,26)
Measurement lines
| Step | Name | Value | Min | Max | Result |
|---|---|---|---|---|---|
| 0.1 | Uložení čísla výrobního příkazu | 50930 | Pass | ||
| 0.2 | Uložení ID obsluhy | 0446 | Pass | ||
| 0.3 | Uložení teploty okolí | 25,92 | Pass | ||
| 0.4 | Uložení vlhkosti okolí | 33,46 | Pass | ||
| 0.5 | Uložení Id testeru (uloženo na lokálním disku) | Vez_Hokami_01-v01.01 | Pass | ||
| 0.6 | Uložení id Artiklu (produktové číslo) | S0000174 | Pass | ||
| 1.1 | DMM: Kontrola hodnoty Odporu (TP2/TP3) | 1000,24307 | 900 | 1100 | Pass |
| 1.2 | DMM: Kontrola hodnoty Odporu (TP4/TP3) | 3294,01143 | 3200 | 3400 | Pass |
| 1.3 | DMM: Kontrola hodnoty Odporu (TP48/TP25,26) | 1000,46548 | 900 | 1100 | Pass |
| 1.4 | DMM: Kontrola hodnoty Odporu (TP13/TP25,26) | 10052,8437 | 9500 | 10500 | Pass |
| 2.1 | DMM: Kontrola hodnoty Odporu (TP36/TP37) | 1061,6412 | 1012 | 1120 | Pass |
| 2.2 | DMM: Kontrola hodnoty Odporu (TP40/TP41) | 1033,13022 | 1012 | 1120 | Pass |
| 4.0 | DMM: Kontrola hodnoty napětí (TP22/TP25,26) | -0,72143532 | -0,75 | -0,65 | Pass |
| 4.1 | NZ1: Odběr proudu ze zdroje (TP25/TP25,26) | 0,01001955 | 0,009 | 1 | Pass |
| 5.1 | NZ1: Odběr proudu ze zdroje (TP22/TP25,26) | 0,03196345 | 0,025 | 0,035 | Pass |
| 5.2 | DMM: Kontrola hodnoty napětí (TP49/TP25,26) | 8,77019353 | 8,7 | 9 | Pass |
| 5.3 | DMM: Kontrola hodnoty napětí (TP17/TP25,26) | 5,00406916 | 4,9 | 5,1 | Pass |
| 5.4 | DMM: Kontrola hodnoty napětí (TP16/TP25,26) | 4,98981758 | 4,9 | 5,1 | Pass |
| 5.5 | DMM: Kontrola hodnoty napětí (TP29/TP25,26) | 4,98978516 | 4,9 | 5,1 | Pass |
| 5.6 | DMM: Kontrola hodnoty napětí (TP14/TP25,26) | 3,29915759 | 3,2 | 3,4 | Pass |
| 5.7 | DMM: Kontrola hodnoty napětí (TP5/TP25,26) | 3,2990942 | 3,2 | 3,4 | Pass |
| 5.8 | DMM: Kontrola hodnoty napětí (TP24/TP25,26) | 8,70232454 | 7,5 | 9 | Pass |
| 5.9 | DMM: Kontrola hodnoty napětí (TP20/TP25,26) | 0,412470264 | 0 | 0,65 | Pass |
| 6.1 | NZ1: Odběr proudu ze zdroje (TP25,26/TP19) | 2,723677E-05 | -0,0001 | 0,0001 | Pass |
| 6.2 | DMM: Kontrola hodnoty napětí (TP20/TP25,26) | 0,295781706 | -0,2 | 0,5 | Pass |
| 6.3 | NZ1: Odběr proudu ze zdroje (TP25,26/TP19) | 0,01997921 | 0,019 | 1 | Pass |
| 7.1 | NZ1: Odběr proudu ze zdroje (TP19/TP25,26) | 9,2546E-05 | < | 0,0001 | Pass |
| 7.1 | NZ1: Odběr proudu ze zdroje (TP19/TP25,26) | 0,006721433 | < | 0,0001 | Fail |
| 7.2 | DMM: Kontrola hodnoty napětí (TP20/TP25,26) | 6,00272935 | 5,95 | 7 | Pass |
| 7.3 | DMM: Kontrola hodnoty napětí (TP50/TP25,26) | 3,1283675 | > | 3 | Pass |
| 7.4 | DMM: Kontrola hodnoty napětí (TP15/TP25,26) | 0,00798788609 | 0 | 0,5 | Pass |
| 7.5 | NZ1: Odběr proudu ze zdroje (TP19/TP25,26) | 0,0006476745 | 0,00057 | 0,0007 | Pass |
| 7.6 | NZ2: Odběr proudu ze zdroje (TP42/TP25,26) | 0,000117527 | -0,001 | 0,0002 | Pass |
| 7.7 | NZ1: Odběr proudu ze zdroje (TP19/TP25,26) | 9,2546E-05 | -0,001 | 0,0001 | Pass |
| 7.8 | DMM: Kontrola hodnoty napětí (TP38/TP25,26) | 8,95855888 | 8,7 | 9 | Pass |
| 9.0 | NZ1: Odběr proudu ze zdroje (TP22/TP25,26) | 0,0407802 | 0 | 0,099 | Pass |
| 9.1 | Vyhodnocení programu: [testSW] | Running... | Fail | ||
| 9.1 | Vyhodnocení programu: [testSW] | 0 | Pass | ||
| 10.2 | NZ1: Odběr proudu ze zdroje (TP19/DLO) | 5,989139E-05 | -0,001 | 0,0002 | Pass |
| 10.3 | NZ2: Odběr proudu ze zdroje (TP42/TP25,26) | 0,0001084434 | -0,001 | 0,0002 | Pass |
| 10.4 | NZ1: Odběr proudu ze zdroje (TP19/DLO) | 0,02670606 | 0,015 | 0,03 | Pass |
| 11.1 | DMM: Kontrola hodnoty proudu (TP25,26/NZ1-) | 0,1445438 | 0,13 | 1 | Pass |
| 11.2 | NZ1: Odběr proudu ze zdroje (TP19/DLO) | 0,02562846 | 0,015 | 0,03 | Pass |
| 12.1 | NZ2: Odběr proudu ze zdroje (TP22/TP25,26) | 0,04074644 | 0,02 | 0,05 | Pass |
| 12.2 | NZ1: Odběr proudu ze zdroje (TP19/DLO) | 2,723677E-05 | -0,001 | 0,0001 | Pass |
| 12.3 | NZ1: Odběr proudu ze zdroje (TP19/DLO) | 0,0255958 | 0,015 | 0,03 | Pass |
| 13.1 | NZ1: Odběr proudu ze zdroje (TP19/DLO) | 2,723677E-05 | -0,001 | 0,0001 | Pass |
| 14.1 | NZ1: Odběr proudu ze zdroje (TP22/TP25,26) | 0,04577636 | 0,03 | 0,06 | Pass |
| 15.1 | Test oscilátorů | 0 (0x00) | 0 (0x00) | 0 (0x00) | Pass |
| 16.1 | Test komunikace mezi U2 a U3 přes RS485 | 0 (0x00) | 0 (0x00) | 0 (0x00) | Pass |
| 17.1 | Test eeprom a ověření velikosti | 0 (0x00) | 0 (0x00) | 0 (0x00) | Pass |
| 17.2 | Test SPI FLASH | 0 (0x00) | 0 (0x00) | 255 (0xff) | Pass |
| 18.1 | Analysis: hodnota na max | True | d_VCC_ADC[3403]<=d_max[3446,35091984844] | Pass | |
| 19.1 | Analysis: hodnota na max | True | d_U5V_ADC[3102]<=d_max[3120,15077566369] | Pass | |
| 19.1 | NZ2: Odběr proudu ze zdroje (TP19/TP25,26) | 0,0001155259 | < | 0,0001 | Fail |
Measurements over time
Hover for exact values · drag to zoom · double-click to reset
Readings (4)
| Date | Value | Min | Max |
|---|---|---|---|
| 2024-11-26 16:59 | 50930 | — | — |
| 2024-11-26 17:04 | 50930 | — | — |
| 2024-11-27 07:39 | 50930 | — | — |
| 2024-11-27 07:41 | 50930 | — | — |