Serial lookup
Search a serial number to see its full test history.
Serial 001129216
Tests17
Approved4
Failures13
Tests over time
Test history
| Date | Measurement ID | ID record | Article | Result | |
|---|---|---|---|---|---|
| 2024-11-26 14:58 | 4305 | 638682263311210193-9201 | S0000174 | Fail | View |
| 2024-11-26 15:01 | 4306 | 638682265134045297-7850 | S0000174 | Fail | View |
| 2024-11-26 15:05 | 4307 | 638682266901015082-1406 | S0000174 | Fail | View |
| 2024-11-26 15:08 | 4308 | 638682268796014557-3550 | S0000174 | Fail | View |
| 2024-11-26 15:17 | 4309 | 638682272051915932-6722 | S0000174 | Fail | View |
| 2024-11-26 15:19 | 4310 | 638682275102237506-2738 | S0000174 | Fail | View |
| 2024-11-26 15:24 | 4311 | 638682278089747429-6044 | S0000174 | Fail | View |
| 2024-11-26 15:35 | 4312 | 638682284591589872-5617 | S0000174 | Fail | View |
| 2024-11-26 15:42 | 4313 | 638682289056009367-7000 | S0000174 | Fail | View |
| 2024-11-26 16:04 | 4314 | 638682302060451566-8590 | S0000174 | Fail | View |
| 2024-11-26 16:10 | 4315 | 638682305592665436-1285 | S0000174 | Fail | View |
| 2024-11-26 16:16 | 4316 | 638682308252094962-7973 | S0000174 | Fail | View |
| 2024-11-26 16:23 | 4317 | 638682311445504289-6778 | S0000174 | Fail | View |
| 2024-11-26 16:25 | 4318 | 638682314445699762-3126 | S0000174 | Pass | View |
| 2024-11-26 16:55 | 4319 | 638682332682576955-8356 | S0000174 | Pass | View |
| 2024-11-26 16:58 | 4320 | 638682334348167566-1204 | S0000174 | Pass | View |
| 2024-11-27 07:43 | 4354 | 638682865472890660-5803 | S0000174 | Pass | View |
Test 4314
- Result
- Fail
- Date
- 2024-11-26 16:04
- Article
- S0000174
- ID record
- 638682302060451566-8590
- ID production
- 50930
- Temperature
- 26,02
- Humidity
- 33,56
- Test duration
- 44
- Error ID
- 414
- Error text
- NZ2: Odběr proudu ze zdroje (TP45/TP25,26)
Measurement lines
| Step | Name | Value | Min | Max | Result |
|---|---|---|---|---|---|
| 0.1 | Uložení čísla výrobního příkazu | 50930 | Pass | ||
| 0.2 | Uložení ID obsluhy | 0446 | Pass | ||
| 0.3 | Uložení teploty okolí | 26,02 | Pass | ||
| 0.4 | Uložení vlhkosti okolí | 33,56 | Pass | ||
| 0.5 | Uložení Id testeru (uloženo na lokálním disku) | Vez_Hokami_01-v01.01 | Pass | ||
| 0.6 | Uložení id Artiklu (produktové číslo) | S0000174 | Pass | ||
| 1.1 | DMM: Kontrola hodnoty Odporu (TP2/TP3) | 995,957743 | 900 | 1100 | Pass |
| 1.2 | DMM: Kontrola hodnoty Odporu (TP4/TP3) | 3298,00769 | 3200 | 3400 | Pass |
| 1.3 | DMM: Kontrola hodnoty Odporu (TP48/TP25,26) | 1001,83751 | 900 | 1100 | Pass |
| 1.4 | DMM: Kontrola hodnoty Odporu (TP13/TP25,26) | 10088,3363 | 9500 | 10500 | Pass |
| 2.1 | DMM: Kontrola hodnoty Odporu (TP36/TP37) | 1065,39466 | 1012 | 1120 | Pass |
| 2.2 | DMM: Kontrola hodnoty Odporu (TP40/TP41) | 1038,46176 | 1012 | 1120 | Pass |
| 4.0 | DMM: Kontrola hodnoty napětí (TP22/TP25,26) | -0,722826699 | -0,75 | -0,65 | Pass |
| 4.1 | NZ1: Odběr proudu ze zdroje (TP25/TP25,26) | 0,01001955 | 0,009 | 1 | Pass |
| 5.1 | NZ1: Odběr proudu ze zdroje (TP22/TP25,26) | 0,0319308 | 0,025 | 0,035 | Pass |
| 5.2 | DMM: Kontrola hodnoty napětí (TP49/TP25,26) | 8,76843714 | 8,7 | 9 | Pass |
| 5.3 | DMM: Kontrola hodnoty napětí (TP17/TP25,26) | 5,03619841 | 4,9 | 5,1 | Pass |
| 5.4 | DMM: Kontrola hodnoty napětí (TP16/TP25,26) | 5,00586069 | 4,9 | 5,1 | Pass |
| 5.5 | DMM: Kontrola hodnoty napětí (TP29/TP25,26) | 5,00586751 | 4,9 | 5,1 | Pass |
| 5.6 | DMM: Kontrola hodnoty napětí (TP14/TP25,26) | 3,29062763 | 3,2 | 3,4 | Pass |
| 5.7 | DMM: Kontrola hodnoty napětí (TP5/TP25,26) | 3,29053058 | 3,2 | 3,4 | Pass |
| 5.8 | DMM: Kontrola hodnoty napětí (TP24/TP25,26) | 8,69966329 | 7,5 | 9 | Pass |
| 5.9 | DMM: Kontrola hodnoty napětí (TP20/TP25,26) | 0,395283507 | 0 | 0,65 | Pass |
| 6.1 | NZ1: Odběr proudu ze zdroje (TP25,26/TP19) | -5,417849E-06 | -0,0001 | 0,0001 | Pass |
| 6.2 | DMM: Kontrola hodnoty napětí (TP20/TP25,26) | 0,30076041 | -0,2 | 0,5 | Pass |
| 6.3 | NZ1: Odběr proudu ze zdroje (TP25,26/TP19) | 0,01997921 | 0,019 | 1 | Pass |
| 7.1 | NZ1: Odběr proudu ze zdroje (TP19/TP25,26) | 5,989139E-05 | 0 | 0,0001 | Pass |
| 7.2 | DMM: Kontrola hodnoty napětí (TP20/TP25,26) | 6,00270776 | 5,95 | 7 | Pass |
| 7.3 | DMM: Kontrola hodnoty napětí (TP50/TP25,26) | 3,1900155 | > | 3 | Pass |
| 7.4 | DMM: Kontrola hodnoty napětí (TP15/TP25,26) | 0,0214601326 | 0 | 0,5 | Pass |
| 7.5 | NZ1: Odběr proudu ze zdroje (TP19/TP25,26) | 0,0006150199 | 0,00057 | 0,00063 | Pass |
| 7.6 | NZ2: Odběr proudu ze zdroje (TP42/TP25,26) | 9,802479E-05 | -0,001 | 0,0002 | Pass |
| 7.7 | NZ1: Odběr proudu ze zdroje (TP19/TP25,26) | 2,723677E-05 | -0,001 | 0,0001 | Pass |
| 7.8 | DMM: Kontrola hodnoty napětí (TP38/TP25,26) | 8,95537292 | 8,7 | 9 | Pass |
| 9.0 | NZ1: Odběr proudu ze zdroje (TP22/TP25,26) | 0,0407802 | 0 | 0,099 | Pass |
| 9.1 | Vyhodnocení programu: [testSW] | Running... | Fail | ||
| 9.1 | Vyhodnocení programu: [testSW] | 0 | Pass | ||
| 10.2 | NZ1: Odběr proudu ze zdroje (TP19/DLO) | 2,723677E-05 | -0,001 | 0,0002 | Pass |
| 10.3 | NZ2: Odběr proudu ze zdroje (TP42/TP25,26) | 9,366201E-05 | -0,001 | 0,0002 | Pass |
| 10.4 | NZ1: Odběr proudu ze zdroje (TP19/DLO) | 0,02654279 | 0,015 | 0,03 | Pass |
| 11.1 | DMM: Kontrola hodnoty proudu (TP25,26/NZ1-) | 0,145136085 | 0,13 | 1 | Pass |
| 11.2 | NZ1: Odběr proudu ze zdroje (TP19/DLO) | 0,02566111 | 0,015 | 0,03 | Pass |
| 12.1 | NZ2: Odběr proudu ze zdroje (TP22/TP25,26) | 0,04215866 | 0,02 | 0,05 | Pass |
| 12.2 | NZ1: Odběr proudu ze zdroje (TP19/DLO) | 2,723677E-05 | -0,001 | 0,0001 | Pass |
| 12.3 | NZ1: Odběr proudu ze zdroje (TP19/DLO) | 0,02575907 | 0,015 | 0,03 | Pass |
| 13.1 | NZ1: Odběr proudu ze zdroje (TP19/DLO) | -5,417849E-06 | -0,001 | 0,0001 | Pass |
| 14.1 | NZ1: Odběr proudu ze zdroje (TP22/TP25,26) | 0,04580901 | 0,03 | 0,06 | Pass |
| 15.1 | Test oscilátorů | 0 (0x00) | 0 (0x00) | 0 (0x00) | Pass |
| 16.1 | Test komunikace mezi U2 a U3 přes RS485 | 0 (0x00) | 0 (0x00) | 0 (0x00) | Pass |
| 17.1 | Test eeprom a ověření velikosti | 0 (0x00) | 0 (0x00) | 0 (0x00) | Pass |
| 17.2 | Test SPI FLASH | 0 (0x00) | 0 (0x00) | 255 (0xff) | Pass |
| 18.1 | Analysis: hodnota na max | True | d_VCC_ADC[3402]<=d_max[3454,68210167373] | Pass | |
| 19.1 | Analysis: hodnota na max | True | d_U5V_ADC[3124]<=d_max[3138,45760903235] | Pass | |
| 19.1 | NZ2: Odběr proudu ze zdroje (TP19/TP25,26) | 3,344123E-05 | -0,0001 | 0,0001 | Pass |
| 19.2 | DMM: Změřit napětí VBATT a uložit (TP20/TP25,26) | d_VBATT=5,99026703 | Pass | ||
| 19.3 | Analysis: hodnota na max | True | d_VBATT_ADC[2338]<=d_max[2355,62817062475] | Pass | |
| 20.1 | NZ2: Odběr proudu ze zdroje (TP42/TP25,26) | 0,0001908304 | -0,0001 | 0,005 | Pass |
| 20.2 | Přečti hodnotu PA4[HW_CH_DET] | 0 | 0 | 0 | Pass |
| 20.3 | DMM: Kontrola hodnoty napětí (TP38/TP25,26) | 0,098002374 | 0 | 0,49 | Pass |
| 20.4 | DMM: Kontrola hodnoty napětí (TP38/TP25,26) | 11,9454147 | 11,7 | 15 | Pass |
| 21.1 | NZ2: Odběr proudu ze zdroje (TP39/TP25,26) | 4,331931E-06 | -0,0001 | 0,001 | Pass |
| 21.2 | DMM: Kontrola hodnoty napětí (TP43/TP25,26) | 11,9327248 | 11,7 | 15 | Pass |
| 22.2 | DMM: Kontrola hodnoty proudu (TP7/R15R) | 0,259345999 | 0,2425 | 0,2775 | Pass |
| 22.2 | DMM: Kontrola hodnoty proudu (TP7/R15R) | 0 | -0,0005 | 0,0005 | Pass |
| 25.1 | NZ2: Odběr proudu ze zdroje (TP45/TP25,26) | 0,199897 | 0,195 | 0,22 | Pass |
| 25.2 | NZ2: Odběr proudu ze zdroje (TP45/TP25,26) | 0,199897 | -0,0005 | 0,009 | Fail |
Measurements over time
Hover for exact values · drag to zoom · double-click to reset
Readings (17)
| Date | Value | Min | Max |
|---|---|---|---|
| 2024-11-26 14:58 | 50930 | — | — |
| 2024-11-26 15:01 | 50930 | — | — |
| 2024-11-26 15:05 | 50930 | — | — |
| 2024-11-26 15:08 | 50930 | — | — |
| 2024-11-26 15:17 | 50930 | — | — |
| 2024-11-26 15:19 | 50930 | — | — |
| 2024-11-26 15:24 | 50930 | — | — |
| 2024-11-26 15:35 | 50930 | — | — |
| 2024-11-26 15:42 | 50930 | — | — |
| 2024-11-26 16:04 | 50930 | — | — |
| 2024-11-26 16:10 | 50930 | — | — |
| 2024-11-26 16:16 | 50930 | — | — |
| 2024-11-26 16:23 | 50930 | — | — |
| 2024-11-26 16:25 | 50930 | — | — |
| 2024-11-26 16:55 | 50930 | — | — |
| 2024-11-26 16:58 | 50930 | — | — |
| 2024-11-27 07:43 | 50930 | — | — |