Serial 001342240

Tests6
Approved1
Failures5

Tests over time

Test history

DateMeasurement IDID recordArticleResult
2024-09-23 13:20 423 638626872036528716-2172 S0000608 Fail View
2024-09-23 13:20 424 638626872364193795-4561 S0000608 Fail View
2024-09-24 13:45 532 638627751023904250-3952 S0000608 Fail View
2024-09-24 13:51 533 638627755040010199-1325 S0000608 Fail View
2024-09-24 13:56 534 638627757561807252-1652 S0000608 Fail View
2024-09-24 13:58 535 638627758395962747-8532 S0000608 Pass View

Test 424

Result
Fail
Date
2024-09-23 13:20
Article
S0000608
ID record
638626872364193795-4561
ID production
47663
Temperature
26,47
Humidity
38,05
Test duration
1
Error ID
57
Error text
DMM: Kontrola hodnoty Odporu (TP2/TP3)

Measurement lines

StepNameValueMinMaxResult
0.1 Uložení čísla výrobního příkazu 47663 Pass
0.2 Uložení ID obsluhy 1816 Pass
0.3 Uložení teploty okolí 26,47 Pass
0.4 Uložení vlhkosti okolí 38,05 Pass
0.5 Uložení Id testeru (uloženo na lokálním disku) Linet_01-v1.1 Pass
0.6 Uložení id Artiklu (produktové číslo) S0000608 Pass
1.1 DMM: Kontrola hodnoty Odporu (TP2/TP3) 1,4394184 -1 1 Fail

Measurements over time

No plottable values for this measurement.

Readings (1)
DateValueMinMax
2024-09-24 13:58