Testing Portal everyone (auth disabled)

Serial lookup

Search a serial number to see its full test history.

Serial 001968976

Tests10
Approved5
Failures5

Tests over time

Test history

DateMeasurement IDID recordArticleResult
2025-11-07 07:25 41094 638980935226636669-9098 S0001055 Fail View
2025-11-07 07:47 41095 638980948188484724-9677 S0001055 Fail View
2025-11-07 07:49 41096 638980949521239232-8694 S0001055 Fail View
2025-11-07 07:54 41097 638980952676282496-9225 S0001055 Fail View
2025-11-07 08:20 41098 638980967728382298-9104 S0001055 Fail View
2025-11-07 08:24 41099 638980968998204584-1711 S0001055 Pass View
2025-11-07 08:26 41100 638980971250518523-1200 S0001055 Pass View
2025-11-07 08:30 41101 638980973404127873-1140 S0001055 Pass View
2025-11-07 08:43 41102 638980981633865015-8684 S0001055 Pass View
2025-11-27 06:30 44732 638998181468274485-1965 S0001055 Pass View

Test 41100

Result
Pass
Date
2025-11-07 08:26
Article
S0001055
ID record
638980971250518523-1200
ID production
52267
Temperature
26.23
Humidity
32.78
Test duration
84
Error ID
Error text

Measurement lines

StepNameValueMinMaxResult
0.0 Dekódování a uložení načteného SN 001968976 Pass
0.1 Uložení čísla výrobního příkazu 52267 Pass
0.2 Uložení ID obsluhy 0008 Pass
0.3 Uložení teploty okolí 26.23 Pass
0.4 Uložení vlhkosti okolí 32.78 Pass
0.5 Uložení Id testeru (uloženo na lokálním disku) Vez_Hokami_01-v01.01 Pass
0.6 Uložení id Artiklu (produktové číslo) S0001055 Pass
1.1 DMM: Kontrola hodnoty Odporu (TP6/TP4) 0.668512152 < 10 Pass
1.2 DMM: Kontrola hodnoty Odporu (TP6/TP5) 1000.77212 800 1200 Pass
3.1 NZ3.1: Měření napětí: Zkrat? 28.00651 > 27.9 Pass
3.2 NZ3.1: Měření proudu: Kontrola odběru 0.000269488 < 0.005 Pass
3.3 R11.12: Zapnutí (TP42/TP43) Pass
3.4 NZ3.1: Měření napětí: Zkrat? 28.00651 > 27.9 Pass
3.5 NZ3.1: Měření proudu: Kontrola odběru 0.02403876 < 0.04 Pass
4.1 DMM: Měření napětí: +BATT (TP49/TP44) 27.9745974 27.9 28.1 Pass
4.2 DMM: Měření napětí: +BATT (TP49/TP34) 27.9971993 27.9 28.1 Pass
4.3 DMM: Měření napětí: +12V (TP49/TP46) 11.895996 11 12.2 Pass
4.4 DMM: Měření napětí: +5V (TP49/TP7) 4.96890445 4.9 5.1 Pass
4.5 DMM: Měření napětí: +3V3 (TP49/TP16) 3.30274616 3.2 3.4 Pass
4.6 DMM: Měření napětí: VDDA +3V3 (TP49/TP2) 3.30274175 3.2 3.4 Pass
4.7 DMM: Měření napětí: (TP49/TP8) 4.65143471 4.57 4.77 Pass
4.8 DMM: Měření napětí: (TP49/TP9) 4.64767522 4.57 4.77 Pass
4.9 DMM: Měření napětí: (TP49/TP10) 4.64781847 4.57 4.77 Pass
5.1 DMM: Měření napětí: (TP49/TP46) 0.539109027 < 1 Pass
5.2 DMM: Měření napětí: (TP49/TP46) 11.8140308 > 11.5 Pass
6.1 R9.12: Vypnutí (TP49/TP28) Pass
7.1 NZ3: Měření napětí: Zkrat? 28.00651 > 27.9 Pass
7.2 NZ3: Měření proudu: Kontrola odběru 0.01197731 < 0.06 Pass
7.3 R0.6: Zapnutí Ext. Programátoru Pass
8.1 TestSw: Ověření komunikace [TYP:AA NAME:eDrive NAME2:TestSW HW:Kolecko v4 SW: Pass
9.1 TestSW: [CHG_SIG (PC14)] = log1? 16384 16384 16384 Pass
9.2 EL1.1: Ověření proudu na zátěži -> Current? 2.003074 1.6 2.8 Pass
9.3 DMM: Měření napětí: Vstup U14 (TP39/TP32) 29.6316274 29 30.1 Pass
9.4 DMM: Měření napětí: Vstup U14 (TP39/TP33) 11.26672 10.8 11.5 Pass
9.5 DMM: Měření napětí: Vstup U14 (TP39/TP40) 1.63313581 1.5 1.8 Pass
10.1 NZ3.1: Měření napětí: Zkrat? 28.00651 > 27.9 Pass
10.2 NZ3.1: Měření proudu: Kontrola odběru 0.02551216 < 0.06 Pass
10.3 TestSW: [ADC_PA03] 3861 3667 3937 Pass
12.1 TestSW: [PA15] - napájení sense ABC Pass
12.2 TestSW: [HALL_A (PB4)] = log0? 0 0 0 Pass
12.3 TestSW: [HALL_A (PB4)] = log1? 16 16 16 Pass
12.4 TestSW: [HALL_B (PB5)] = log0? 0 0 0 Pass
12.5 TestSW: [HALL_B (PB5)] = log1? 32 32 32 Pass
12.6 TestSW: [HALL_C (PB0)] = log0? 0 0 0 Pass
12.7 TestSW: [HALL_C (PB0)] = log1? 1 1 1 Pass
13.1 TestSW: [CON_ID (PC13)] = log1? 8192 8192 8192 Pass
13.10 TestSW: [BTN_FFWD][ADC_PA6]? 4085 4000 4096 Pass
13.11 TestSW: [BTN_FFWD][ADC_PA6]? 2033 1900 2100 Pass
13.12 TestSW: [BTN_STOP][ADC_PA5]? 4085 4000 4096 Pass
13.13 TestSW: [BTN_STOP][ADC_PA5]? 2041 1900 2100 Pass
13.2 TestSW: [CON_ID (PC13)] = log0? 0 0 0 Pass
13.3 TestSW: [BTN_DRV][PA11] na log1 Pass
13.4 TestSW: [BTN_FWD][ADC_PB1]? 4085 4000 4096 Pass
13.5 TestSW: [BTN_FWD][ADC_PB1]? 2007 1900 2100 Pass
13.6 TestSW: [BTN_REV][ADC_PA4]? 4085 4000 4096 Pass
13.7 TestSW: [BTN_REV][ADC_PA4]? 2035 1900 2100 Pass
13.8 TestSW: [BTN_ULCK][ADC_PA7]? 4086 4000 4096 Pass
13.9 TestSW: [BTN_ULCK][ADC_PA7]? 2043 1900 2100 Pass
14.1 TestSW: [LED1][PB2] na log1 Pass
14.10 DMM: Měření napětí: LED3 (TP49/TP14) 3.29821027 > 3 Pass
14.11 TestSW: [LED3][PB11] na log0 Pass
14.12 DMM: Měření napětí: LED3 (TP49/TP14) 0.00357380346 < 0.1 Pass
14.13 TestSW: [LED4][PB12] na log1 Pass
14.14 DMM: Měření napětí: LED4 (TP49/TP12) 3.29956942 > 3 Pass
14.15 TestSW: [LED4][PB12] na log0 Pass
14.16 DMM: Měření napětí: LED4 (TP49/TP12) 0.0035412153 < 0.1 Pass
14.2 DMM: Měření napětí: LED1 (TP49/TP13) 3.29798673 > 3 Pass
14.3 TestSW: [LED1][PB2] na log0 Pass
14.4 DMM: Měření napětí: LED1 (TP49/TP13) 0.00372924985 < 0.1 Pass
14.5 TestSW: [LED2][PB10] na log1 Pass
14.6 DMM: Měření napětí: LED1 (TP49/TP11) 3.29817787 > 3 Pass
14.7 TestSW: [LED2][PB10] na log0 Pass
14.8 DMM: Měření napětí: LED1 (TP49/TP11) 0.00358870309 < 0.1 Pass
14.9 TestSW: [LED3][PB11] na log1 Pass
15.1 TestSW: ntc 73 49 90 Pass
16.1 DMM: Měření frekvence (TP49/TP55) 19995.1795 19600 20400 Pass
16.2 DMM: Měření frekvence (TP49/TP56) 19995.172 19600 20400 Pass
16.3 DMM: Měření napětí (TP49/TP52) 14.006126 13.3 14.7 Pass
17.1 DMM: Měření frekvence (TP49/TP61) 19995.1725 19600 20400 Pass
17.2 DMM: Měření frekvence (TP49/TP62) 19995.1739 19600 20400 Pass
17.3 DMM: Měření napětí (TP49/TP58) 14.0061393 13.3 14.7 Pass
18.1 DMM: Měření frekvence (TP49/TP67) 19995.172 19600 20400 Pass
18.2 DMM: Měření frekvence (TP49/TP68) 19995.1758 19600 20400 Pass
18.3 DMM: Měření napětí (TP49/TP58) 14.0037351 13.3 14.7 Pass
19.1 DMM: Měření napětí: +5V (TP49/TP7) -0.000196178514 < 0.5 Pass
20.0.1 TestSW: [ADC_PA0] sense A do var VA = 2256 Pass
20.0.2 TestSW: [ADC_PA1] sense B do var VB = 2254 Pass
20.0.3 TestSW: [ADC_PA2] sense C do var VC = 2250 Pass
20.0.5 Analysis: VA VA[2256] 2210 2340 Pass
20.0.6 Analysis: VB VB[2254] 2210 2340 Pass
20.0.7 Analysis: VC VC[2250] 2210 2340 Pass
20.1 NZ3.1: Měření napětí: Zkrat? 28.00651 > 27.9 Pass
20.1.1 EL1.2: Ověření proudu na zátěži -> Current? 4.989486 4.7 5.3 Pass
20.1.2 TestSW: [ADC_PA0] sense A 2431 2421[VA] 2521[VA] Pass
20.1.3 TestSW: [ADC_PA1] sense B 2080 1989[VB] 2089[VB] Pass
20.1.4 TestSW: [ADC_PA2] sense C 2250 2210 2340 Pass
20.2 NZ3.1: Měření proudu: Kontrola odběru 0.0384164 < 0.06 Pass
20.2.1 EL1.2: Ověření proudu na zátěži -> Current? 4.989662 4.7 5.3 Pass
20.2.2 TestSW: [ADC_PA0] sense A 2079 1991[VA] 2091[VA] Pass
20.2.3 TestSW: [ADC_PA1] sense B 2426 2419[VB] 2519[VB] Pass
20.2.4 TestSW: [ADC_PA2] sense C 2250 2210 2340 Pass
20.3.1 EL1.2: Ověření proudu na zátěži -> Current? 4.989678 4.7 5.3 Pass
20.3.2 TestSW: [ADC_PA0] sense A 2431 2421[VA] 2521[VA] Pass
20.3.3 TestSW: [ADC_PA1] sense B 2256 2210 2340 Pass
20.3.4 TestSW: [ADC_PA2] sense C 2077 1985[VC] 2085[VC] Pass
20.4.1 EL1.2: Ověření proudu na zátěži -> Current? 4.989677 4.7 5.3 Pass
20.4.2 TestSW: [ADC_PA0] sense A 2079 1991[VA] 2091[VA] Pass
20.4.3 TestSW: [ADC_PA1] sense B 2251 2210 2340 Pass
20.4.4 TestSW: [ADC_PA2] sense C 2422 2415[VC] 2515[VC] Pass
20.5.1 EL1.2: Ověření proudu na zátěži -> Current? 4.989563 4.7 5.3 Pass
20.5.2 TestSW: [ADC_PA0] sense A 2256 2210 2340 Pass
20.5.3 TestSW: [ADC_PA1] sense B 2428 2419[VB] 2519[VB] Pass
20.5.4 TestSW: [ADC_PA2] sense C 2077 1985[VC] 2085[VC] Pass
20.6.1 EL1.2: Ověření proudu na zátěži -> Current? 4.989764 4.7 5.3 Pass
20.6.2 TestSW: [ADC_PA0] sense A 2255 2210 2340 Pass
20.6.3 TestSW: [ADC_PA1] sense B 2077 1989[VB] 2089[VB] Pass
20.6.4 TestSW: [ADC_PA2] sense C 2422 2415[VC] 2515[VC] Pass
23.1 DMM: měření RMS(TP49/TP67) 0.15635658 0.1 1.6 Pass

Measurements over time

Hover for exact values · drag to zoom · double-click to reset

Readings (10)
DateValueMinMax
2025-11-07 07:25 1968976
2025-11-07 07:47 1968976
2025-11-07 07:49 1968976
2025-11-07 07:54 1968976
2025-11-07 08:20 1968976
2025-11-07 08:24 1968976
2025-11-07 08:26 1968976
2025-11-07 08:30 1968976
2025-11-07 08:43 1968976
2025-11-27 06:30 1968976