Testing Portal everyone (auth disabled)

Serial lookup

Search a serial number to see its full test history.

Serial 001968854

Tests6
Approved0
Failures6

Tests over time

Test history

DateMeasurement IDID recordArticleResult
2025-11-06 13:15 40630 638980280812081232-5978 S0001055 Fail View
2026-07-09 13:50 77711 639192017701657214-7551 S0001055 Fail View
2026-07-09 13:51 77712 639192018249371196-4152 S0001055 Fail View
2026-07-09 13:52 77713 639192019343560994-2557 S0001055 Fail View
2026-07-09 14:15 77736 639192032690638428-3278 S0001055 Fail View
2026-07-09 14:37 77740 639192046123369904-2980 S0001055 Fail View

Test 40630

Result
Fail
Date
2025-11-06 13:15
Article
S0001055
ID record
638980280812081232-5978
ID production
52267
Temperature
26.43
Humidity
32.28
Test duration
54
Error ID
358
Error text
TestSW: [ADC_PA1] sense B

Measurement lines

StepNameValueMinMaxResult
0.0 Dekódování a uložení načteného SN 001968854 Pass
0.1 Uložení čísla výrobního příkazu 52267 Pass
0.2 Uložení ID obsluhy 0681 Pass
0.3 Uložení teploty okolí 26.43 Pass
0.4 Uložení vlhkosti okolí 32.28 Pass
0.5 Uložení Id testeru (uloženo na lokálním disku) Vez_Hokami_01-v01.01 Pass
0.6 Uložení id Artiklu (produktové číslo) S0001055 Pass
1.1 DMM: Kontrola hodnoty Odporu (TP6/TP4) 0.860425059 < 10 Pass
1.2 DMM: Kontrola hodnoty Odporu (TP6/TP5) 1001.15367 800 1200 Pass
3.1 NZ3.1: Měření napětí: Zkrat? 28.00651 > 27.9 Pass
3.2 NZ3.1: Měření proudu: Kontrola odběru 0.001795955 < 0.005 Pass
3.3 R11.12: Zapnutí (TP42/TP43) Pass
3.4 NZ3.1: Měření napětí: Zkrat? 28.00851 > 27.9 Pass
3.5 NZ3.1: Měření proudu: Kontrola odběru 0.02468115 < 0.04 Pass
4.1 DMM: Měření napětí: +BATT (TP49/TP44) 27.9707191 27.9 28.1 Pass
4.2 DMM: Měření napětí: +BATT (TP49/TP34) 27.996623 27.9 28.1 Pass
4.3 DMM: Měření napětí: +12V (TP49/TP46) 11.8489974 11 12.2 Pass
4.4 DMM: Měření napětí: +5V (TP49/TP7) 4.99603907 4.9 5.1 Pass
4.5 DMM: Měření napětí: +3V3 (TP49/TP16) 3.32001704 3.2 3.4 Pass
4.6 DMM: Měření napětí: VDDA +3V3 (TP49/TP2) 3.32002164 3.2 3.4 Pass
4.7 DMM: Měření napětí: (TP49/TP8) 4.67634349 4.57 4.77 Pass
4.8 DMM: Měření napětí: (TP49/TP9) 4.67177994 4.57 4.77 Pass
4.9 DMM: Měření napětí: (TP49/TP10) 4.67142113 4.57 4.77 Pass
5.1 DMM: Měření napětí: (TP49/TP46) 0.573156107 < 1 Pass
5.2 DMM: Měření napětí: (TP49/TP46) 11.7629864 > 11.5 Pass
6.1 R9.12: Vypnutí (TP49/TP28) Pass
7.1 NZ3: Měření napětí: Zkrat? 28.00851 > 27.9 Pass
7.2 NZ3: Měření proudu: Kontrola odběru 0.02433342 < 0.06 Pass
7.3 R0.6: Zapnutí Ext. Programátoru Pass
8.1 TestSw: Ověření komunikace [TYP:AA NAME:eDrive NAME2:TestSW HW:Kolecko v4 SW: Pass
9.1 TestSW: [CHG_SIG (PC14)] = log1? 16384 16384 16384 Pass
9.2 EL1.1: Ověření proudu na zátěži -> Current? 2.063977 1.6 2.8 Pass
9.3 DMM: Měření napětí: Vstup U14 (TP39/TP32) 29.621414 29 30.1 Pass
9.4 DMM: Měření napětí: Vstup U14 (TP39/TP33) 11.3172453 10.8 11.5 Pass
9.5 DMM: Měření napětí: Vstup U14 (TP39/TP40) 1.56239303 1.5 1.8 Pass
10.1 NZ3.1: Měření napětí: Zkrat? 28.00851 > 27.9 Pass
10.2 NZ3.1: Měření proudu: Kontrola odběru 0.02546501 < 0.06 Pass
10.3 TestSW: [ADC_PA03] 3835 3667 3937 Pass
12.1 TestSW: [PA15] - napájení sense ABC Pass
12.2 TestSW: [HALL_A (PB4)] = log0? 0 0 0 Pass
12.3 TestSW: [HALL_A (PB4)] = log1? 16 16 16 Pass
12.4 TestSW: [HALL_B (PB5)] = log0? 0 0 0 Pass
12.5 TestSW: [HALL_B (PB5)] = log1? 32 32 32 Pass
12.6 TestSW: [HALL_C (PB0)] = log0? 0 0 0 Pass
12.7 TestSW: [HALL_C (PB0)] = log1? 1 1 1 Pass
13.1 TestSW: [CON_ID (PC13)] = log1? 8192 8192 8192 Pass
13.10 TestSW: [BTN_FFWD][ADC_PA6]? 4085 4000 4096 Pass
13.11 TestSW: [BTN_FFWD][ADC_PA6]? 2038 1900 2100 Pass
13.12 TestSW: [BTN_STOP][ADC_PA5]? 4085 4000 4096 Pass
13.13 TestSW: [BTN_STOP][ADC_PA5]? 2039 1900 2100 Pass
13.2 TestSW: [CON_ID (PC13)] = log0? 0 0 0 Pass
13.3 TestSW: [BTN_DRV][PA11] na log1 Pass
13.4 TestSW: [BTN_FWD][ADC_PB1]? 4084 4000 4096 Pass
13.5 TestSW: [BTN_FWD][ADC_PB1]? 2010 1900 2100 Pass
13.6 TestSW: [BTN_REV][ADC_PA4]? 4085 4000 4096 Pass
13.7 TestSW: [BTN_REV][ADC_PA4]? 2033 1900 2100 Pass
13.8 TestSW: [BTN_ULCK][ADC_PA7]? 4085 4000 4096 Pass
13.9 TestSW: [BTN_ULCK][ADC_PA7]? 2042 1900 2100 Pass
14.1 TestSW: [LED1][PB2] na log1 Pass
14.10 DMM: Měření napětí: LED3 (TP49/TP14) 3.31562003 > 3 Pass
14.11 TestSW: [LED3][PB11] na log0 Pass
14.12 DMM: Měření napětí: LED3 (TP49/TP14) 0.00351578795 < 0.1 Pass
14.13 TestSW: [LED4][PB12] na log1 Pass
14.14 DMM: Měření napětí: LED4 (TP49/TP12) 3.31687569 > 3 Pass
14.15 TestSW: [LED4][PB12] na log0 Pass
14.16 DMM: Měření napětí: LED4 (TP49/TP12) 0.00350490293 < 0.1 Pass
14.2 DMM: Měření napětí: LED1 (TP49/TP13) 3.31541976 > 3 Pass
14.3 TestSW: [LED1][PB2] na log0 Pass
14.4 DMM: Měření napětí: LED1 (TP49/TP13) 0.003652375 < 0.1 Pass
14.5 TestSW: [LED2][PB10] na log1 Pass
14.6 DMM: Měření napětí: LED1 (TP49/TP11) 3.31558242 > 3 Pass
14.7 TestSW: [LED2][PB10] na log0 Pass
14.8 DMM: Měření napětí: LED1 (TP49/TP11) 0.00352975072 < 0.1 Pass
14.9 TestSW: [LED3][PB11] na log1 Pass
15.1 TestSW: ntc 79 49 90 Pass
16.1 DMM: Měření frekvence (TP49/TP55) 19995.2417 19600 20400 Pass
16.2 DMM: Měření frekvence (TP49/TP56) 19995.2422 19600 20400 Pass
16.3 DMM: Měření napětí (TP49/TP52) 14.0100547 13.3 14.7 Pass
17.1 DMM: Měření frekvence (TP49/TP61) 19995.2384 19600 20400 Pass
17.2 DMM: Měření frekvence (TP49/TP62) 19995.2398 19600 20400 Pass
17.3 DMM: Měření napětí (TP49/TP58) 14.0060181 13.3 14.7 Pass
18.1 DMM: Měření frekvence (TP49/TP67) 19995.2365 19600 20400 Pass
18.2 DMM: Měření frekvence (TP49/TP68) 19995.2422 19600 20400 Pass
18.3 DMM: Měření napětí (TP49/TP58) 14.007596 13.3 14.7 Pass
19.1 DMM: Měření napětí: +5V (TP49/TP7) -0.00156339602 < 0.5 Pass
20.0.1 TestSW: [ADC_PA0] sense A do var VA = 2254 Pass
20.0.2 TestSW: [ADC_PA1] sense B do var VB = 2252 Pass
20.0.3 TestSW: [ADC_PA2] sense C do var VC = 2251 Pass
20.0.5 Analysis: VA VA[2254] 2210 2340 Pass
20.0.6 Analysis: VB VB[2252] 2210 2340 Pass
20.0.7 Analysis: VC VC[2251] 2210 2340 Pass
20.1.3 TestSW: [ADC_PA1] sense B 1962 1987[VB] 2087[VB] Fail
20.1.2 TestSW: [ADC_PA0] sense A 2431 2419[VA] 2519[VA] Pass
20.1.1 EL1.2: Ověření proudu na zátěži -> Current? 4.989771 4.7 5.3 Pass
20.1 NZ3.1: Měření napětí: Zkrat? 28.00851 > 27.9 Pass
20.2 NZ3.1: Měření proudu: Kontrola odběru 0.03810699 < 0.06 Pass

Measurements over time

Hover for exact values · drag to zoom · double-click to reset

Readings (5)
DateValueMinMax
2026-07-09 13:50 1.034 10
2026-07-09 13:51 1.001 10
2026-07-09 13:52 1.035 10
2026-07-09 14:15 0.981 10
2026-07-09 14:37 0.961 10