Testing Portal everyone (auth disabled)

Serial lookup

Search a serial number to see its full test history.

Serial 001676337

Tests7
Approved0
Failures7

Tests over time

Test history

DateMeasurement IDID recordArticleResult
2025-09-05 10:12 25807 638926566915049846-9147 S0001055 Fail View
2025-11-06 17:12 40608 638980422898917957-2183 S0001055 Fail View
2026-07-09 16:26 77807 639192111310406157-9403 S0001055 Fail View
2026-07-09 16:27 77808 639192111929755589-4514 S0001055 Fail View
2026-07-09 16:28 77809 639192112575286326-7623 S0001055 Fail View
2026-07-09 16:29 77810 639192113242717822-3402 S0001055 Fail View
2026-07-09 16:30 77811 639192113957316372-2106 S0001055 Fail View

Test 40608

Result
Fail
Date
2025-11-06 17:12
Article
S0001055
ID record
638980422898917957-2183
ID production
49348
Temperature
26.25
Humidity
31.15
Test duration
54
Error ID
371
Error text
TestSW: [ADC_PA1] sense B

Measurement lines

StepNameValueMinMaxResult
0.0 Dekódování a uložení načteného SN 001676337 Pass
0.1 Uložení čísla výrobního příkazu 49348 Pass
0.2 Uložení ID obsluhy 1332 Pass
0.3 Uložení teploty okolí 26.25 Pass
0.4 Uložení vlhkosti okolí 31.15 Pass
0.5 Uložení Id testeru (uloženo na lokálním disku) Vez_Hokami_01-v01.01 Pass
0.6 Uložení id Artiklu (produktové číslo) S0001055 Pass
1.1 DMM: Kontrola hodnoty Odporu (TP6/TP4) 0.783139878 < 10 Pass
1.2 DMM: Kontrola hodnoty Odporu (TP6/TP5) 1005.90669 800 1200 Pass
3.1 NZ3.1: Měření napětí: Zkrat? 28.00851 > 27.9 Pass
3.2 NZ3.1: Měření proudu: Kontrola odběru 0.001047433 < 0.005 Pass
3.3 R11.12: Zapnutí (TP42/TP43) Pass
3.4 NZ3.1: Měření napětí: Zkrat? 28.00651 > 27.9 Pass
3.5 NZ3.1: Měření proudu: Kontrola odběru 0.02457508 < 0.04 Pass
4.1 DMM: Měření napětí: +BATT (TP49/TP44) 27.9626165 27.9 28.1 Pass
4.2 DMM: Měření napětí: +BATT (TP49/TP34) 27.9955885 27.9 28.1 Pass
4.3 DMM: Měření napětí: +12V (TP49/TP46) 11.840203 11 12.2 Pass
4.4 DMM: Měření napětí: +5V (TP49/TP7) 5.00347503 4.9 5.1 Pass
4.5 DMM: Měření napětí: +3V3 (TP49/TP16) 3.30843264 3.2 3.4 Pass
4.6 DMM: Měření napětí: VDDA +3V3 (TP49/TP2) 3.30843072 3.2 3.4 Pass
4.7 DMM: Měření napětí: (TP49/TP8) 4.68575755 4.57 4.77 Pass
4.8 DMM: Měření napětí: (TP49/TP9) 4.68163645 4.57 4.77 Pass
4.9 DMM: Měření napětí: (TP49/TP10) 4.6821586 4.57 4.77 Pass
5.1 DMM: Měření napětí: (TP49/TP46) 0.555405864 < 1 Pass
5.2 DMM: Měření napětí: (TP49/TP46) 11.7576038 > 11.5 Pass
6.1 R9.12: Vypnutí (TP49/TP28) Pass
7.1 NZ3: Měření napětí: Zkrat? 28.00851 > 27.9 Pass
7.2 NZ3: Měření proudu: Kontrola odběru 0.02550334 < 0.06 Pass
7.3 R0.6: Zapnutí Ext. Programátoru Pass
8.1 TestSw: Ověření komunikace [TYP:AA NAME:eDrive NAME2:TestSW HW:Kolecko v4 SW: Pass
9.1 TestSW: [CHG_SIG (PC14)] = log1? 16384 16384 16384 Pass
9.2 EL1.1: Ověření proudu na zátěži -> Current? 2.120451 1.6 2.8 Pass
9.3 DMM: Měření napětí: Vstup U14 (TP39/TP32) 29.5522414 29 30.1 Pass
9.4 DMM: Měření napětí: Vstup U14 (TP39/TP33) 11.3427423 10.8 11.5 Pass
9.5 DMM: Měření napětí: Vstup U14 (TP39/TP40) 1.62110658 1.5 1.8 Pass
10.1 NZ3.1: Měření napětí: Zkrat? 28.00851 > 27.9 Pass
10.2 NZ3.1: Měření proudu: Kontrola odběru 0.02536187 < 0.06 Pass
10.3 TestSW: [ADC_PA03] 3839 3667 3937 Pass
12.1 TestSW: [PA15] - napájení sense ABC Pass
12.2 TestSW: [HALL_A (PB4)] = log0? 0 0 0 Pass
12.3 TestSW: [HALL_A (PB4)] = log1? 16 16 16 Pass
12.4 TestSW: [HALL_B (PB5)] = log0? 0 0 0 Pass
12.5 TestSW: [HALL_B (PB5)] = log1? 32 32 32 Pass
12.6 TestSW: [HALL_C (PB0)] = log0? 0 0 0 Pass
12.7 TestSW: [HALL_C (PB0)] = log1? 1 1 1 Pass
13.1 TestSW: [CON_ID (PC13)] = log1? 8192 8192 8192 Pass
13.10 TestSW: [BTN_FFWD][ADC_PA6]? 4085 4000 4096 Pass
13.11 TestSW: [BTN_FFWD][ADC_PA6]? 2040 1900 2100 Pass
13.12 TestSW: [BTN_STOP][ADC_PA5]? 4085 4000 4096 Pass
13.13 TestSW: [BTN_STOP][ADC_PA5]? 2037 1900 2100 Pass
13.2 TestSW: [CON_ID (PC13)] = log0? 0 0 0 Pass
13.3 TestSW: [BTN_DRV][PA11] na log1 Pass
13.4 TestSW: [BTN_FWD][ADC_PB1]? 4084 4000 4096 Pass
13.5 TestSW: [BTN_FWD][ADC_PB1]? 2010 1900 2100 Pass
13.6 TestSW: [BTN_REV][ADC_PA4]? 4084 4000 4096 Pass
13.7 TestSW: [BTN_REV][ADC_PA4]? 2030 1900 2100 Pass
13.8 TestSW: [BTN_ULCK][ADC_PA7]? 4085 4000 4096 Pass
13.9 TestSW: [BTN_ULCK][ADC_PA7]? 2028 1900 2100 Pass
14.1 TestSW: [LED1][PB2] na log1 Pass
14.10 DMM: Měření napětí: LED3 (TP49/TP14) 3.30367559 > 3 Pass
14.11 TestSW: [LED3][PB11] na log0 Pass
14.12 DMM: Měření napětí: LED3 (TP49/TP14) 0.00346762253 < 0.1 Pass
14.13 TestSW: [LED4][PB12] na log1 Pass
14.14 DMM: Měření napětí: LED4 (TP49/TP12) 3.30486986 > 3 Pass
14.15 TestSW: [LED4][PB12] na log0 Pass
14.16 DMM: Měření napětí: LED4 (TP49/TP12) 0.00346391155 < 0.1 Pass
14.2 DMM: Měření napětí: LED1 (TP49/TP13) 3.30355707 > 3 Pass
14.3 TestSW: [LED1][PB2] na log0 Pass
14.4 DMM: Měření napětí: LED1 (TP49/TP13) 0.00356264188 < 0.1 Pass
14.5 TestSW: [LED2][PB10] na log1 Pass
14.6 DMM: Měření napětí: LED1 (TP49/TP11) 3.30366807 > 3 Pass
14.7 TestSW: [LED2][PB10] na log0 Pass
14.8 DMM: Měření napětí: LED1 (TP49/TP11) 0.0034819855 < 0.1 Pass
14.9 TestSW: [LED3][PB11] na log1 Pass
15.1 TestSW: ntc 79 49 90 Pass
16.1 DMM: Měření frekvence (TP49/TP55) 19995.2266 19600 20400 Pass
16.2 DMM: Měření frekvence (TP49/TP56) 19995.2271 19600 20400 Pass
16.3 DMM: Měření napětí (TP49/TP52) 14.0095971 13.3 14.7 Pass
17.1 DMM: Měření frekvence (TP49/TP61) 19995.2196 19600 20400 Pass
17.2 DMM: Měření frekvence (TP49/TP62) 19995.2228 19600 20400 Pass
17.3 DMM: Měření napětí (TP49/TP58) 14.0091268 13.3 14.7 Pass
18.1 DMM: Měření frekvence (TP49/TP67) 19995.2191 19600 20400 Pass
18.2 DMM: Měření frekvence (TP49/TP68) 19995.2228 19600 20400 Pass
18.3 DMM: Měření napětí (TP49/TP58) 14.0087744 13.3 14.7 Pass
19.1 DMM: Měření napětí: +5V (TP49/TP7) 0.00164290334 < 0.5 Pass
20.0.3 TestSW: [ADC_PA2] sense C do var VC = 2267 Pass
20.0.7 Analysis: VC VC[2267] 2210 2340 Pass
20.0.6 Analysis: VB VB[2265] 2210 2340 Pass
20.0.5 Analysis: VA VA[2271] 2210 2340 Pass
20.0.2 TestSW: [ADC_PA1] sense B do var VB = 2265 Pass
20.0.1 TestSW: [ADC_PA0] sense A do var VA = 2271 Pass
20.1 NZ3.1: Měření napětí: Zkrat? 28.00851 > 27.9 Pass
20.1.1 EL1.2: Ověření proudu na zátěži -> Current? 4.989857 4.7 5.3 Pass
20.1.2 TestSW: [ADC_PA0] sense A 2440 2436[VA] 2536[VA] Pass
20.1.3 TestSW: [ADC_PA1] sense B 2100 2000[VB] 2100[VB] Pass
20.1.4 TestSW: [ADC_PA2] sense C 2267 2210 2340 Pass
20.2 NZ3.1: Měření proudu: Kontrola odběru 0.03801563 < 0.06 Pass
20.2.1 EL1.2: Ověření proudu na zátěži -> Current? 4.989708 4.7 5.3 Pass
20.2.2 TestSW: [ADC_PA0] sense A 2101 2006[VA] 2106[VA] Pass
20.2.3 TestSW: [ADC_PA1] sense B 2428 2430[VB] 2530[VB] Fail

Measurements over time

Hover for exact values · drag to zoom · double-click to reset

Readings (5)
DateValueMinMax
2026-07-09 16:26 1.109 10
2026-07-09 16:27 0.994 10
2026-07-09 16:28 0.968 10
2026-07-09 16:29 0.957 10
2026-07-09 16:30 0.957 10