Testing Portal everyone (auth disabled)

Serial lookup

Search a serial number to see its full test history.

Serial 001676313

Tests4
Approved0
Failures4

Tests over time

Test history

DateMeasurement IDID recordArticleResult
2025-09-05 10:44 25803 638926585918255982-4220 S0001055 Fail View
2025-11-06 17:18 40604 638980426552702921-9295 S0001055 Fail View
2026-07-09 16:22 77804 639192108766160014-4964 S0001055 Fail View
2026-07-09 16:23 77805 639192109403437576-7258 S0001055 Fail View

Test 40604

Result
Fail
Date
2025-11-06 17:18
Article
S0001055
ID record
638980426552702921-9295
ID production
49348
Temperature
26.3
Humidity
31.15
Test duration
54
Error ID
371
Error text
TestSW: [ADC_PA1] sense B

Measurement lines

StepNameValueMinMaxResult
0.0 Dekódování a uložení načteného SN 001676313 Pass
0.1 Uložení čísla výrobního příkazu 49348 Pass
0.2 Uložení ID obsluhy 1332 Pass
0.3 Uložení teploty okolí 26.3 Pass
0.4 Uložení vlhkosti okolí 31.15 Pass
0.5 Uložení Id testeru (uloženo na lokálním disku) Vez_Hokami_01-v01.01 Pass
0.6 Uložení id Artiklu (produktové číslo) S0001055 Pass
1.1 DMM: Kontrola hodnoty Odporu (TP6/TP4) 0.675046476 < 10 Pass
1.2 DMM: Kontrola hodnoty Odporu (TP6/TP5) 1009.57069 800 1200 Pass
3.1 NZ3.1: Měření napětí: Zkrat? 28.00851 > 27.9 Pass
3.2 NZ3.1: Měření proudu: Kontrola odběru 0.001053349 < 0.005 Pass
3.3 R11.12: Zapnutí (TP42/TP43) Pass
3.4 NZ3.1: Měření napětí: Zkrat? 28.00651 > 27.9 Pass
3.5 NZ3.1: Měření proudu: Kontrola odběru 0.02445426 < 0.04 Pass
4.1 DMM: Měření napětí: +BATT (TP49/TP44) 27.9596268 27.9 28.1 Pass
4.2 DMM: Měření napětí: +BATT (TP49/TP34) 27.9958998 27.9 28.1 Pass
4.3 DMM: Měření napětí: +12V (TP49/TP46) 11.8700839 11 12.2 Pass
4.4 DMM: Měření napětí: +5V (TP49/TP7) 4.99804073 4.9 5.1 Pass
4.5 DMM: Měření napětí: +3V3 (TP49/TP16) 3.31215835 3.2 3.4 Pass
4.6 DMM: Měření napětí: VDDA +3V3 (TP49/TP2) 3.31216778 3.2 3.4 Pass
4.7 DMM: Měření napětí: (TP49/TP8) 4.68010409 4.57 4.77 Pass
4.8 DMM: Měření napětí: (TP49/TP9) 4.67600023 4.57 4.77 Pass
4.9 DMM: Měření napětí: (TP49/TP10) 4.67567058 4.57 4.77 Pass
5.1 DMM: Měření napětí: (TP49/TP46) 0.556317385 < 1 Pass
5.2 DMM: Měření napětí: (TP49/TP46) 11.7801162 > 11.5 Pass
6.1 R9.12: Vypnutí (TP49/TP28) Pass
7.1 NZ3: Měření napětí: Zkrat? 28.00651 > 27.9 Pass
7.2 NZ3: Měření proudu: Kontrola odběru 0.02565952 < 0.06 Pass
7.3 R0.6: Zapnutí Ext. Programátoru Pass
8.1 TestSw: Ověření komunikace [TYP:AA NAME:eDrive NAME2:TestSW HW:Kolecko v4 SW: Pass
9.1 TestSW: [CHG_SIG (PC14)] = log1? 16384 16384 16384 Pass
9.2 EL1.1: Ověření proudu na zátěži -> Current? 2.112319 1.6 2.8 Pass
9.3 DMM: Měření napětí: Vstup U14 (TP39/TP32) 29.5787163 29 30.1 Pass
9.4 DMM: Měření napětí: Vstup U14 (TP39/TP33) 11.341326 10.8 11.5 Pass
9.5 DMM: Měření napětí: Vstup U14 (TP39/TP40) 1.58714718 1.5 1.8 Pass
10.1 NZ3.1: Měření napětí: Zkrat? 28.00851 > 27.9 Pass
10.2 NZ3.1: Měření proudu: Kontrola odběru 0.02550626 < 0.06 Pass
10.3 TestSW: [ADC_PA03] 3838 3667 3937 Pass
12.1 TestSW: [PA15] - napájení sense ABC Pass
12.2 TestSW: [HALL_A (PB4)] = log0? 0 0 0 Pass
12.3 TestSW: [HALL_A (PB4)] = log1? 16 16 16 Pass
12.4 TestSW: [HALL_B (PB5)] = log0? 0 0 0 Pass
12.5 TestSW: [HALL_B (PB5)] = log1? 32 32 32 Pass
12.6 TestSW: [HALL_C (PB0)] = log0? 0 0 0 Pass
12.7 TestSW: [HALL_C (PB0)] = log1? 1 1 1 Pass
13.1 TestSW: [CON_ID (PC13)] = log1? 8192 8192 8192 Pass
13.10 TestSW: [BTN_FFWD][ADC_PA6]? 4085 4000 4096 Pass
13.11 TestSW: [BTN_FFWD][ADC_PA6]? 2032 1900 2100 Pass
13.12 TestSW: [BTN_STOP][ADC_PA5]? 4085 4000 4096 Pass
13.13 TestSW: [BTN_STOP][ADC_PA5]? 2036 1900 2100 Pass
13.2 TestSW: [CON_ID (PC13)] = log0? 0 0 0 Pass
13.3 TestSW: [BTN_DRV][PA11] na log1 Pass
13.4 TestSW: [BTN_FWD][ADC_PB1]? 4084 4000 4096 Pass
13.5 TestSW: [BTN_FWD][ADC_PB1]? 2011 1900 2100 Pass
13.6 TestSW: [BTN_REV][ADC_PA4]? 4085 4000 4096 Pass
13.7 TestSW: [BTN_REV][ADC_PA4]? 2030 1900 2100 Pass
13.8 TestSW: [BTN_ULCK][ADC_PA7]? 4085 4000 4096 Pass
13.9 TestSW: [BTN_ULCK][ADC_PA7]? 2036 1900 2100 Pass
14.1 TestSW: [LED1][PB2] na log1 Pass
14.10 DMM: Měření napětí: LED3 (TP49/TP14) 3.30777847 > 3 Pass
14.11 TestSW: [LED3][PB11] na log0 Pass
14.12 DMM: Měření napětí: LED3 (TP49/TP14) 0.00352225508 < 0.1 Pass
14.13 TestSW: [LED4][PB12] na log1 Pass
14.14 DMM: Měření napětí: LED4 (TP49/TP12) 3.30904851 > 3 Pass
14.15 TestSW: [LED4][PB12] na log0 Pass
14.16 DMM: Měření napětí: LED4 (TP49/TP12) 0.0035145957 < 0.1 Pass
14.2 DMM: Měření napětí: LED1 (TP49/TP13) 3.30757185 > 3 Pass
14.3 TestSW: [LED1][PB2] na log0 Pass
14.4 DMM: Měření napětí: LED1 (TP49/TP13) 0.00373768854 < 0.1 Pass
14.5 TestSW: [LED2][PB10] na log1 Pass
14.6 DMM: Měření napětí: LED1 (TP49/TP11) 3.30774696 > 3 Pass
14.7 TestSW: [LED2][PB10] na log0 Pass
14.8 DMM: Měření napětí: LED1 (TP49/TP11) 0.00353594815 < 0.1 Pass
14.9 TestSW: [LED3][PB11] na log1 Pass
15.1 TestSW: ntc 75 49 90 Pass
16.1 DMM: Měření frekvence (TP49/TP55) 19995.1682 19600 20400 Pass
16.2 DMM: Měření frekvence (TP49/TP56) 19995.1682 19600 20400 Pass
16.3 DMM: Měření napětí (TP49/TP52) 14.0057326 13.3 14.7 Pass
17.1 DMM: Měření frekvence (TP49/TP61) 19995.1645 19600 20400 Pass
17.2 DMM: Měření frekvence (TP49/TP62) 19995.1682 19600 20400 Pass
17.3 DMM: Měření napětí (TP49/TP58) 14.0013783 13.3 14.7 Pass
18.1 DMM: Měření frekvence (TP49/TP67) 19995.1607 19600 20400 Pass
18.2 DMM: Měření frekvence (TP49/TP68) 19995.1663 19600 20400 Pass
18.3 DMM: Měření napětí (TP49/TP58) 14.0067856 13.3 14.7 Pass
19.1 DMM: Měření napětí: +5V (TP49/TP7) 0.0123739479 < 0.5 Pass
20.0.3 TestSW: [ADC_PA2] sense C do var VC = 2264 Pass
20.0.7 Analysis: VC VC[2264] 2210 2340 Pass
20.0.6 Analysis: VB VB[2268] 2210 2340 Pass
20.0.5 Analysis: VA VA[2264] 2210 2340 Pass
20.0.2 TestSW: [ADC_PA1] sense B do var VB = 2268 Pass
20.0.1 TestSW: [ADC_PA0] sense A do var VA = 2264 Pass
20.1 NZ3.1: Měření napětí: Zkrat? 28.00851 > 27.9 Pass
20.1.1 EL1.2: Ověření proudu na zátěži -> Current? 4.989676 4.7 5.3 Pass
20.1.2 TestSW: [ADC_PA0] sense A 2432 2429[VA] 2529[VA] Pass
20.1.3 TestSW: [ADC_PA1] sense B 2101 2003[VB] 2103[VB] Pass
20.1.4 TestSW: [ADC_PA2] sense C 2264 2210 2340 Pass
20.2 NZ3.1: Měření proudu: Kontrola odběru 0.03798616 < 0.06 Pass
20.2.1 EL1.2: Ověření proudu na zátěži -> Current? 4.989852 4.7 5.3 Pass
20.2.2 TestSW: [ADC_PA0] sense A 2095 1999[VA] 2099[VA] Pass
20.2.3 TestSW: [ADC_PA1] sense B 2432 2433[VB] 2533[VB] Fail

Measurements over time

Hover for exact values · drag to zoom · double-click to reset

Readings (2)
DateValueMinMax
2026-07-09 16:22 1.124 10
2026-07-09 16:23 0.991 10