Tests7
Approved0
Failures7

Tests over time

Test history

DateMeasurement IDID recordArticleResult
2025-09-05 10:49 25782 638926589748398488-1805 S0001055 Fail View
2025-11-06 17:08 40600 638980420325771203-3759 S0001055 Fail View
2026-02-05 07:32 51265 639058734979627464-4271 S0001055 Fail View
2026-07-09 16:12 77794 639192102925471102-2298 S0001055 Fail View
2026-07-09 16:13 77795 639192103554876122-5937 S0001055 Fail View
2026-07-09 16:14 77796 639192104213483551-9616 S0001055 Fail View
2026-07-09 16:15 77797 639192104914145718-5307 S0001055 Fail View

Test 40600

Result
Fail
Date
2025-11-06 17:08
Article
S0001055
ID record
638980420325771203-3759
ID production
49348
Temperature
26.34
Humidity
31.21
Test duration
54
Error ID
371
Error text
TestSW: [ADC_PA1] sense B

Measurement lines

StepNameValueMinMaxResult
0.0 Dekódování a uložení načteného SN 001676182 Pass
0.1 Uložení čísla výrobního příkazu 49348 Pass
0.2 Uložení ID obsluhy 1332 Pass
0.3 Uložení teploty okolí 26.34 Pass
0.4 Uložení vlhkosti okolí 31.21 Pass
0.5 Uložení Id testeru (uloženo na lokálním disku) Vez_Hokami_01-v01.01 Pass
0.6 Uložení id Artiklu (produktové číslo) S0001055 Pass
1.1 DMM: Kontrola hodnoty Odporu (TP6/TP4) 0.81933424 < 10 Pass
1.2 DMM: Kontrola hodnoty Odporu (TP6/TP5) 1002.4591 800 1200 Pass
3.1 NZ3.1: Měření napětí: Zkrat? 28.00851 > 27.9 Pass
3.2 NZ3.1: Měření proudu: Kontrola odběru 0.001294968 < 0.005 Pass
3.3 R11.12: Zapnutí (TP42/TP43) Pass
3.4 NZ3.1: Měření napětí: Zkrat? 28.00851 > 27.9 Pass
3.5 NZ3.1: Měření proudu: Kontrola odběru 0.02466052 < 0.04 Pass
4.1 DMM: Měření napětí: +BATT (TP49/TP44) 27.9587973 27.9 28.1 Pass
4.2 DMM: Měření napětí: +BATT (TP49/TP34) 27.9962409 27.9 28.1 Pass
4.3 DMM: Měření napětí: +12V (TP49/TP46) 11.8840149 11 12.2 Pass
4.4 DMM: Měření napětí: +5V (TP49/TP7) 4.98207755 4.9 5.1 Pass
4.5 DMM: Měření napětí: +3V3 (TP49/TP16) 3.30534114 3.2 3.4 Pass
4.6 DMM: Měření napětí: VDDA +3V3 (TP49/TP2) 3.30534399 3.2 3.4 Pass
4.7 DMM: Měření napětí: (TP49/TP8) 4.66400572 4.57 4.77 Pass
4.8 DMM: Měření napětí: (TP49/TP9) 4.66219187 4.57 4.77 Pass
4.9 DMM: Měření napětí: (TP49/TP10) 4.66098478 4.57 4.77 Pass
5.1 DMM: Měření napětí: (TP49/TP46) 0.559237865 < 1 Pass
5.2 DMM: Měření napětí: (TP49/TP46) 11.7956908 > 11.5 Pass
6.1 R9.12: Vypnutí (TP49/TP28) Pass
7.1 NZ3: Měření napětí: Zkrat? 28.00851 > 27.9 Pass
7.2 NZ3: Měření proudu: Kontrola odběru 0.02560059 < 0.06 Pass
7.3 R0.6: Zapnutí Ext. Programátoru Pass
8.1 TestSw: Ověření komunikace [TYP:AA NAME:eDrive NAME2:TestSW HW:Kolecko v4 SW: Pass
9.1 TestSW: [CHG_SIG (PC14)] = log1? 16384 16384 16384 Pass
9.2 EL1.1: Ověření proudu na zátěži -> Current? 2.024252 1.6 2.8 Pass
9.3 DMM: Měření napětí: Vstup U14 (TP39/TP32) 29.5692815 29 30.1 Pass
9.4 DMM: Měření napětí: Vstup U14 (TP39/TP33) 11.3070485 10.8 11.5 Pass
9.5 DMM: Měření napětí: Vstup U14 (TP39/TP40) 1.55229213 1.5 1.8 Pass
10.1 NZ3.1: Měření napětí: Zkrat? 28.00851 > 27.9 Pass
10.2 NZ3.1: Měření proudu: Kontrola odběru 0.02537071 < 0.06 Pass
10.3 TestSW: [ADC_PA03] 3816 3667 3937 Pass
12.1 TestSW: [PA15] - napájení sense ABC Pass
12.2 TestSW: [HALL_A (PB4)] = log0? 0 0 0 Pass
12.3 TestSW: [HALL_A (PB4)] = log1? 16 16 16 Pass
12.4 TestSW: [HALL_B (PB5)] = log0? 0 0 0 Pass
12.5 TestSW: [HALL_B (PB5)] = log1? 32 32 32 Pass
12.6 TestSW: [HALL_C (PB0)] = log0? 0 0 0 Pass
12.7 TestSW: [HALL_C (PB0)] = log1? 1 1 1 Pass
13.1 TestSW: [CON_ID (PC13)] = log1? 8192 8192 8192 Pass
13.10 TestSW: [BTN_FFWD][ADC_PA6]? 4079 4000 4096 Pass
13.11 TestSW: [BTN_FFWD][ADC_PA6]? 2027 1900 2100 Pass
13.12 TestSW: [BTN_STOP][ADC_PA5]? 4079 4000 4096 Pass
13.13 TestSW: [BTN_STOP][ADC_PA5]? 2029 1900 2100 Pass
13.2 TestSW: [CON_ID (PC13)] = log0? 0 0 0 Pass
13.3 TestSW: [BTN_DRV][PA11] na log1 Pass
13.4 TestSW: [BTN_FWD][ADC_PB1]? 4078 4000 4096 Pass
13.5 TestSW: [BTN_FWD][ADC_PB1]? 2009 1900 2100 Pass
13.6 TestSW: [BTN_REV][ADC_PA4]? 4079 4000 4096 Pass
13.7 TestSW: [BTN_REV][ADC_PA4]? 2030 1900 2100 Pass
13.8 TestSW: [BTN_ULCK][ADC_PA7]? 4079 4000 4096 Pass
13.9 TestSW: [BTN_ULCK][ADC_PA7]? 2032 1900 2100 Pass
14.1 TestSW: [LED1][PB2] na log1 Pass
14.10 DMM: Měření napětí: LED3 (TP49/TP14) 3.30098183 > 3 Pass
14.11 TestSW: [LED3][PB11] na log0 Pass
14.12 DMM: Měření napětí: LED3 (TP49/TP14) 0.00347656771 < 0.1 Pass
14.13 TestSW: [LED4][PB12] na log1 Pass
14.14 DMM: Měření napětí: LED4 (TP49/TP12) 3.30222807 > 3 Pass
14.15 TestSW: [LED4][PB12] na log0 Pass
14.16 DMM: Měření napětí: LED4 (TP49/TP12) 0.00345927567 < 0.1 Pass
14.2 DMM: Měření napětí: LED1 (TP49/TP13) 3.30074439 > 3 Pass
14.3 TestSW: [LED1][PB2] na log0 Pass
14.4 DMM: Měření napětí: LED1 (TP49/TP13) 0.0036407718 < 0.1 Pass
14.5 TestSW: [LED2][PB10] na log1 Pass
14.6 DMM: Měření napětí: LED1 (TP49/TP11) 3.30095583 > 3 Pass
14.7 TestSW: [LED2][PB10] na log0 Pass
14.8 DMM: Měření napětí: LED1 (TP49/TP11) 0.00349831841 < 0.1 Pass
14.9 TestSW: [LED3][PB11] na log1 Pass
15.1 TestSW: ntc 81 49 90 Pass
16.1 DMM: Měření frekvence (TP49/TP55) 19995.2115 19600 20400 Pass
16.2 DMM: Měření frekvence (TP49/TP56) 19995.2115 19600 20400 Pass
16.3 DMM: Měření napětí (TP49/TP52) 14.0016411 13.3 14.7 Pass
17.1 DMM: Měření frekvence (TP49/TP61) 19995.204 19600 20400 Pass
17.2 DMM: Měření frekvence (TP49/TP62) 19995.2115 19600 20400 Pass
17.3 DMM: Měření napětí (TP49/TP58) 14.0092682 13.3 14.7 Pass
18.1 DMM: Měření frekvence (TP49/TP67) 19995.2045 19600 20400 Pass
18.2 DMM: Měření frekvence (TP49/TP68) 19995.2078 19600 20400 Pass
18.3 DMM: Měření napětí (TP49/TP58) 14.0038932 13.3 14.7 Pass
19.1 DMM: Měření napětí: +5V (TP49/TP7) -0.000722320563 < 0.5 Pass
20.0.3 TestSW: [ADC_PA2] sense C do var VC = 2258 Pass
20.0.7 Analysis: VC VC[2258] 2210 2340 Pass
20.0.6 Analysis: VB VB[2255] 2210 2340 Pass
20.0.5 Analysis: VA VA[2259] 2210 2340 Pass
20.0.2 TestSW: [ADC_PA1] sense B do var VB = 2255 Pass
20.0.1 TestSW: [ADC_PA0] sense A do var VA = 2259 Pass
20.1 NZ3.1: Měření napětí: Zkrat? 28.00851 > 27.9 Pass
20.1.1 EL1.2: Ověření proudu na zátěži -> Current? 4.98977 4.7 5.3 Pass
20.1.2 TestSW: [ADC_PA0] sense A 2426 2424[VA] 2524[VA] Pass
20.1.3 TestSW: [ADC_PA1] sense B 2089 1990[VB] 2090[VB] Pass
20.1.4 TestSW: [ADC_PA2] sense C 2258 2210 2340 Pass
20.2 NZ3.1: Měření proudu: Kontrola odběru 0.03792723 < 0.06 Pass
20.2.1 EL1.2: Ověření proudu na zátěži -> Current? 4.989828 4.7 5.3 Pass
20.2.2 TestSW: [ADC_PA0] sense A 2090 1994[VA] 2094[VA] Pass
20.2.3 TestSW: [ADC_PA1] sense B 2419 2420[VB] 2520[VB] Fail

Measurements over time

Hover for exact values · drag to zoom · double-click to reset

Readings (4)
DateValueMinMax
2026-07-09 16:12 0.998 10
2026-07-09 16:13 0.973 10
2026-07-09 16:14 0.961 10
2026-07-09 16:15 0.97 10