Serial 001676181

Tests4
Approved0
Failures4

Tests over time

Test history

DateMeasurement IDID recordArticleResult
2025-09-05 10:45 25781 638926586921144995-7216 S0001055 Fail View
2025-11-06 17:13 40599 638980423723682352-1222 S0001055 Fail View
2026-07-09 16:17 77798 639192105678756815-5150 S0001055 Fail View
2026-07-09 16:18 77799 639192106358317659-4158 S0001055 Fail View

Test 40599

Result
Fail
Date
2025-11-06 17:13
Article
S0001055
ID record
638980423723682352-1222
ID production
49348
Temperature
26.25
Humidity
31.15
Test duration
55
Error ID
385
Error text
TestSW: [ADC_PA2] sense C

Measurement lines

StepNameValueMinMaxResult
0.0 Dekódování a uložení načteného SN 001676181 Pass
0.1 Uložení čísla výrobního příkazu 49348 Pass
0.2 Uložení ID obsluhy 1332 Pass
0.3 Uložení teploty okolí 26.25 Pass
0.4 Uložení vlhkosti okolí 31.15 Pass
0.5 Uložení Id testeru (uloženo na lokálním disku) Vez_Hokami_01-v01.01 Pass
0.6 Uložení id Artiklu (produktové číslo) S0001055 Pass
1.1 DMM: Kontrola hodnoty Odporu (TP6/TP4) 0.742254382 < 10 Pass
1.2 DMM: Kontrola hodnoty Odporu (TP6/TP5) 1000.60759 800 1200 Pass
3.1 NZ3.1: Měření napětí: Zkrat? 28.00651 > 27.9 Pass
3.2 NZ3.1: Měření proudu: Kontrola odběru 0.001073977 < 0.005 Pass
3.3 R11.12: Zapnutí (TP42/TP43) Pass
3.4 NZ3.1: Měření napětí: Zkrat? 28.00651 > 27.9 Pass
3.5 NZ3.1: Měření proudu: Kontrola odběru 0.02428921 < 0.04 Pass
4.1 DMM: Měření napětí: +BATT (TP49/TP44) 27.9615674 27.9 28.1 Pass
4.2 DMM: Měření napětí: +BATT (TP49/TP34) 27.9958903 27.9 28.1 Pass
4.3 DMM: Měření napětí: +12V (TP49/TP46) 11.8291483 11 12.2 Pass
4.4 DMM: Měření napětí: +5V (TP49/TP7) 4.99549293 4.9 5.1 Pass
4.5 DMM: Měření napětí: +3V3 (TP49/TP16) 3.30730097 3.2 3.4 Pass
4.6 DMM: Měření napětí: VDDA +3V3 (TP49/TP2) 3.30731706 3.2 3.4 Pass
4.7 DMM: Měření napětí: (TP49/TP8) 4.67811116 4.57 4.77 Pass
4.8 DMM: Měření napětí: (TP49/TP9) 4.67355858 4.57 4.77 Pass
4.9 DMM: Měření napětí: (TP49/TP10) 4.67313023 4.57 4.77 Pass
5.1 DMM: Měření napětí: (TP49/TP46) 0.556116677 < 1 Pass
5.2 DMM: Měření napětí: (TP49/TP46) 11.739815 > 11.5 Pass
6.1 R9.12: Vypnutí (TP49/TP28) Pass
7.1 NZ3: Měření napětí: Zkrat? 28.00651 > 27.9 Pass
7.2 NZ3: Měření proudu: Kontrola odběru 0.02544733 < 0.06 Pass
7.3 R0.6: Zapnutí Ext. Programátoru Pass
8.1 TestSw: Ověření komunikace [TYP:AA NAME:eDrive NAME2:TestSW HW:Kolecko v4 SW: Pass
9.1 TestSW: [CHG_SIG (PC14)] = log1? 16384 16384 16384 Pass
9.2 EL1.1: Ověření proudu na zátěži -> Current? 1.928278 1.6 2.8 Pass
9.3 DMM: Měření napětí: Vstup U14 (TP39/TP32) 29.6025587 29 30.1 Pass
9.4 DMM: Měření napětí: Vstup U14 (TP39/TP33) 11.2320088 10.8 11.5 Pass
9.5 DMM: Měření napětí: Vstup U14 (TP39/TP40) 1.54663169 1.5 1.8 Pass
10.1 NZ3.1: Měření napětí: Zkrat? 28.00851 > 27.9 Pass
10.2 NZ3.1: Měření proudu: Kontrola odběru 0.02524105 < 0.06 Pass
10.3 TestSW: [ADC_PA03] 3825 3667 3937 Pass
12.1 TestSW: [PA15] - napájení sense ABC Pass
12.2 TestSW: [HALL_A (PB4)] = log0? 0 0 0 Pass
12.3 TestSW: [HALL_A (PB4)] = log1? 16 16 16 Pass
12.4 TestSW: [HALL_B (PB5)] = log0? 0 0 0 Pass
12.5 TestSW: [HALL_B (PB5)] = log1? 32 32 32 Pass
12.6 TestSW: [HALL_C (PB0)] = log0? 0 0 0 Pass
12.7 TestSW: [HALL_C (PB0)] = log1? 1 1 1 Pass
13.1 TestSW: [CON_ID (PC13)] = log1? 8192 8192 8192 Pass
13.10 TestSW: [BTN_FFWD][ADC_PA6]? 4085 4000 4096 Pass
13.11 TestSW: [BTN_FFWD][ADC_PA6]? 2028 1900 2100 Pass
13.12 TestSW: [BTN_STOP][ADC_PA5]? 4085 4000 4096 Pass
13.13 TestSW: [BTN_STOP][ADC_PA5]? 2036 1900 2100 Pass
13.2 TestSW: [CON_ID (PC13)] = log0? 0 0 0 Pass
13.3 TestSW: [BTN_DRV][PA11] na log1 Pass
13.4 TestSW: [BTN_FWD][ADC_PB1]? 4084 4000 4096 Pass
13.5 TestSW: [BTN_FWD][ADC_PB1]? 2010 1900 2100 Pass
13.6 TestSW: [BTN_REV][ADC_PA4]? 4085 4000 4096 Pass
13.7 TestSW: [BTN_REV][ADC_PA4]? 2028 1900 2100 Pass
13.8 TestSW: [BTN_ULCK][ADC_PA7]? 4085 4000 4096 Pass
13.9 TestSW: [BTN_ULCK][ADC_PA7]? 2038 1900 2100 Pass
14.1 TestSW: [LED1][PB2] na log1 Pass
14.10 DMM: Měření napětí: LED3 (TP49/TP14) 3.30334668 > 3 Pass
14.11 TestSW: [LED3][PB11] na log0 Pass
14.12 DMM: Měření napětí: LED3 (TP49/TP14) 0.00347834144 < 0.1 Pass
14.13 TestSW: [LED4][PB12] na log1 Pass
14.14 DMM: Měření napětí: LED4 (TP49/TP12) 3.30462986 > 3 Pass
14.15 TestSW: [LED4][PB12] na log0 Pass
14.16 DMM: Měření napětí: LED4 (TP49/TP12) 0.00346004886 < 0.1 Pass
14.2 DMM: Měření napětí: LED1 (TP49/TP13) 3.30306925 > 3 Pass
14.3 TestSW: [LED1][PB2] na log0 Pass
14.4 DMM: Měření napětí: LED1 (TP49/TP13) 0.00362769764 < 0.1 Pass
14.5 TestSW: [LED2][PB10] na log1 Pass
14.6 DMM: Měření napětí: LED1 (TP49/TP11) 3.30330276 > 3 Pass
14.7 TestSW: [LED2][PB10] na log0 Pass
14.8 DMM: Měření napětí: LED1 (TP49/TP11) 0.00349909544 < 0.1 Pass
14.9 TestSW: [LED3][PB11] na log1 Pass
15.1 TestSW: ntc 78 49 90 Pass
16.1 DMM: Měření frekvence (TP49/TP55) 19995.2059 19600 20400 Pass
16.2 DMM: Měření frekvence (TP49/TP56) 19995.204 19600 20400 Pass
16.3 DMM: Měření napětí (TP49/TP52) 14.007631 13.3 14.7 Pass
17.1 DMM: Měření frekvence (TP49/TP61) 19995.2002 19600 20400 Pass
17.2 DMM: Měření frekvence (TP49/TP62) 19995.204 19600 20400 Pass
17.3 DMM: Měření napětí (TP49/TP58) 14.0063153 13.3 14.7 Pass
18.1 DMM: Měření frekvence (TP49/TP67) 19995.1984 19600 20400 Pass
18.2 DMM: Měření frekvence (TP49/TP68) 19995.1889 19600 20400 Pass
18.3 DMM: Měření napětí (TP49/TP58) 14.0253627 13.3 14.7 Pass
19.1 DMM: Měření napětí: +5V (TP49/TP7) -0.00178712297 < 0.5 Pass
20.0.1 TestSW: [ADC_PA0] sense A do var VA = 2265 Pass
20.0.2 TestSW: [ADC_PA1] sense B do var VB = 2261 Pass
20.0.3 TestSW: [ADC_PA2] sense C do var VC = 2262 Pass
20.0.5 Analysis: VA VA[2265] 2210 2340 Pass
20.0.6 Analysis: VB VB[2261] 2210 2340 Pass
20.0.7 Analysis: VC VC[2262] 2210 2340 Pass
20.1 NZ3.1: Měření napětí: Zkrat? 28.00851 > 27.9 Pass
20.1.1 EL1.2: Ověření proudu na zátěži -> Current? 4.989802 4.7 5.3 Pass
20.1.2 TestSW: [ADC_PA0] sense A 2435 2430[VA] 2530[VA] Pass
20.1.3 TestSW: [ADC_PA1] sense B 2094 1996[VB] 2096[VB] Pass
20.1.4 TestSW: [ADC_PA2] sense C 2262 2210 2340 Pass
20.2 NZ3.1: Měření proudu: Kontrola odběru 0.0376178 < 0.06 Pass
20.2.1 EL1.2: Ověření proudu na zátěži -> Current? 4.989727 4.7 5.3 Pass
20.2.2 TestSW: [ADC_PA0] sense A 2095 2000[VA] 2100[VA] Pass
20.2.3 TestSW: [ADC_PA1] sense B 2427 2426[VB] 2526[VB] Pass
20.2.4 TestSW: [ADC_PA2] sense C 2261 2210 2340 Pass
20.3.1 EL1.2: Ověření proudu na zátěži -> Current? 4.989753 4.7 5.3 Pass
20.3.2 TestSW: [ADC_PA0] sense A 2435 2430[VA] 2530[VA] Pass
20.3.3 TestSW: [ADC_PA1] sense B 2263 2210 2340 Pass
20.3.4 TestSW: [ADC_PA2] sense C 2099 1997[VC] 2097[VC] Fail

Measurements over time

Hover for exact values · drag to zoom · double-click to reset

Readings (2)
DateValueMinMax
2026-07-09 16:17 1.076 10
2026-07-09 16:18 0.975 10