Serial 001791580

Tests13
Approved1
Failures12

Tests over time

Test history

DateMeasurement IDID recordArticleResult
2024-09-04 14:18 120 638610490692017824-6076 S0001055 Fail View
2024-09-04 14:44 121 638610506211302571-9122 S0001055 Fail View
2024-09-23 08:54 525 638626712179833309-7388 S0001055 Fail View
2024-12-05 15:02 5425 638690041226339881-7396 S0001055 Fail View
2024-12-05 15:18 5426 638690050503788650-1421 S0001055 Fail View
2025-09-05 11:34 25773 638926615940184172-8600 S0001055 Fail View
2025-11-06 17:26 40595 638980431637054293-8233 S0001055 Fail View
2026-07-09 14:56 77750 639192057461952391-5550 S0001055 Fail View
2026-07-09 15:30 77774 639192077659903818-4534 S0001055 Fail View
2026-07-09 15:31 77775 639192078342481215-9283 S0001055 Fail View
2026-07-09 15:32 77776 639192079224402463-4603 S0001055 Fail View
2026-07-09 15:34 77777 639192079918677658-2895 S0001055 Fail View
2026-08-11 04:53 81272 639220207238377596-2682 S0001055 Pass View

Test 40595

Result
Fail
Date
2025-11-06 17:26
Article
S0001055
ID record
638980431637054293-8233
ID production
49267
Temperature
26.4
Humidity
31.32
Test duration
55
Error ID
398
Error text
TestSW: [ADC_PA2] sense C

Measurement lines

StepNameValueMinMaxResult
0.0 Dekódování a uložení načteného SN 001791580 Pass
0.1 Uložení čísla výrobního příkazu 49267 Pass
0.2 Uložení ID obsluhy 1332 Pass
0.3 Uložení teploty okolí 26.4 Pass
0.4 Uložení vlhkosti okolí 31.32 Pass
0.5 Uložení Id testeru (uloženo na lokálním disku) Vez_Hokami_01-v01.01 Pass
0.6 Uložení id Artiklu (produktové číslo) S0001055 Pass
1.1 DMM: Kontrola hodnoty Odporu (TP6/TP4) 0.704640791 < 10 Pass
1.2 DMM: Kontrola hodnoty Odporu (TP6/TP5) 1005.02578 800 1200 Pass
3.1 NZ3.1: Měření napětí: Zkrat? 28.00651 > 27.9 Pass
3.2 NZ3.1: Měření proudu: Kontrola odběru 0.0008735916 < 0.005 Pass
3.3 R11.12: Zapnutí (TP42/TP43) Pass
3.4 NZ3.1: Měření napětí: Zkrat? 28.00651 > 27.9 Pass
3.5 NZ3.1: Měření proudu: Kontrola odběru 0.02455738 < 0.04 Pass
4.1 DMM: Měření napětí: +BATT (TP49/TP44) 27.9695252 27.9 28.1 Pass
4.2 DMM: Měření napětí: +BATT (TP49/TP34) 27.9966554 27.9 28.1 Pass
4.3 DMM: Měření napětí: +12V (TP49/TP46) 11.8475812 11 12.2 Pass
4.4 DMM: Měření napětí: +5V (TP49/TP7) 5.00328654 4.9 5.1 Pass
4.5 DMM: Měření napětí: +3V3 (TP49/TP16) 3.30967864 3.2 3.4 Pass
4.6 DMM: Měření napětí: VDDA +3V3 (TP49/TP2) 3.3096902 3.2 3.4 Pass
4.7 DMM: Měření napětí: (TP49/TP8) 4.68416519 4.57 4.77 Pass
4.8 DMM: Měření napětí: (TP49/TP9) 4.68043057 4.57 4.77 Pass
4.9 DMM: Měření napětí: (TP49/TP10) 4.67950092 4.57 4.77 Pass
5.1 DMM: Měření napětí: (TP49/TP46) 0.523067417 < 1 Pass
5.2 DMM: Měření napětí: (TP49/TP46) 11.758622 > 11.5 Pass
6.1 R9.12: Vypnutí (TP49/TP28) Pass
7.1 NZ3: Měření napětí: Zkrat? 28.00851 > 27.9 Pass
7.2 NZ3: Měření proudu: Kontrola odběru 0.02555636 < 0.06 Pass
7.3 R0.6: Zapnutí Ext. Programátoru Pass
8.1 TestSw: Ověření komunikace [TYP:AA NAME:eDrive NAME2:TestSW HW:Kolecko v4 SW: Pass
9.1 TestSW: [CHG_SIG (PC14)] = log1? 16384 16384 16384 Pass
9.2 EL1.1: Ověření proudu na zátěži -> Current? 2.106181 1.6 2.8 Pass
9.3 DMM: Měření napětí: Vstup U14 (TP39/TP32) 29.5764719 29 30.1 Pass
9.4 DMM: Měření napětí: Vstup U14 (TP39/TP33) 11.3167891 10.8 11.5 Pass
9.5 DMM: Měření napětí: Vstup U14 (TP39/TP40) 1.60526923 1.5 1.8 Pass
10.1 NZ3.1: Měření napětí: Zkrat? 28.00851 > 27.9 Pass
10.2 NZ3.1: Měření proudu: Kontrola odběru 0.02554752 < 0.06 Pass
10.3 TestSW: [ADC_PA03] 3827 3667 3937 Pass
12.1 TestSW: [PA15] - napájení sense ABC Pass
12.2 TestSW: [HALL_A (PB4)] = log0? 0 0 0 Pass
12.3 TestSW: [HALL_A (PB4)] = log1? 16 16 16 Pass
12.4 TestSW: [HALL_B (PB5)] = log0? 0 0 0 Pass
12.5 TestSW: [HALL_B (PB5)] = log1? 32 32 32 Pass
12.6 TestSW: [HALL_C (PB0)] = log0? 0 0 0 Pass
12.7 TestSW: [HALL_C (PB0)] = log1? 1 1 1 Pass
13.1 TestSW: [CON_ID (PC13)] = log1? 8192 8192 8192 Pass
13.10 TestSW: [BTN_FFWD][ADC_PA6]? 4085 4000 4096 Pass
13.11 TestSW: [BTN_FFWD][ADC_PA6]? 2024 1900 2100 Pass
13.12 TestSW: [BTN_STOP][ADC_PA5]? 4085 4000 4096 Pass
13.13 TestSW: [BTN_STOP][ADC_PA5]? 2026 1900 2100 Pass
13.2 TestSW: [CON_ID (PC13)] = log0? 0 0 0 Pass
13.3 TestSW: [BTN_DRV][PA11] na log1 Pass
13.4 TestSW: [BTN_FWD][ADC_PB1]? 4084 4000 4096 Pass
13.5 TestSW: [BTN_FWD][ADC_PB1]? 2009 1900 2100 Pass
13.6 TestSW: [BTN_REV][ADC_PA4]? 4085 4000 4096 Pass
13.7 TestSW: [BTN_REV][ADC_PA4]? 2027 1900 2100 Pass
13.8 TestSW: [BTN_ULCK][ADC_PA7]? 4085 4000 4096 Pass
13.9 TestSW: [BTN_ULCK][ADC_PA7]? 2028 1900 2100 Pass
14.1 TestSW: [LED1][PB2] na log1 Pass
14.10 DMM: Měření napětí: LED3 (TP49/TP14) 3.30553768 > 3 Pass
14.11 TestSW: [LED3][PB11] na log0 Pass
14.12 DMM: Měření napětí: LED3 (TP49/TP14) 0.0035231737 < 0.1 Pass
14.13 TestSW: [LED4][PB12] na log1 Pass
14.14 DMM: Měření napětí: LED4 (TP49/TP12) 3.30680155 > 3 Pass
14.15 TestSW: [LED4][PB12] na log0 Pass
14.16 DMM: Měření napětí: LED4 (TP49/TP12) 0.00349233208 < 0.1 Pass
14.2 DMM: Měření napětí: LED1 (TP49/TP13) 3.30532106 > 3 Pass
14.3 TestSW: [LED1][PB2] na log0 Pass
14.4 DMM: Měření napětí: LED1 (TP49/TP13) 0.00372288115 < 0.1 Pass
14.5 TestSW: [LED2][PB10] na log1 Pass
14.6 DMM: Měření napětí: LED1 (TP49/TP11) 3.30547398 > 3 Pass
14.7 TestSW: [LED2][PB10] na log0 Pass
14.8 DMM: Měření napětí: LED1 (TP49/TP11) 0.00359008867 < 0.1 Pass
14.9 TestSW: [LED3][PB11] na log1 Pass
15.1 TestSW: ntc 58 49 90 Pass
16.1 DMM: Měření frekvence (TP49/TP55) 19995.099 19600 20400 Pass
16.2 DMM: Měření frekvence (TP49/TP56) 19995.0985 19600 20400 Pass
16.3 DMM: Měření napětí (TP49/TP52) 14.0120751 13.3 14.7 Pass
17.1 DMM: Měření frekvence (TP49/TP61) 19995.0952 19600 20400 Pass
17.2 DMM: Měření frekvence (TP49/TP62) 19995.099 19600 20400 Pass
17.3 DMM: Měření napětí (TP49/TP58) 14.0077836 13.3 14.7 Pass
18.1 DMM: Měření frekvence (TP49/TP67) 19995.0948 19600 20400 Pass
18.2 DMM: Měření frekvence (TP49/TP68) 19995.0985 19600 20400 Pass
18.3 DMM: Měření napětí (TP49/TP58) 14.003157 13.3 14.7 Pass
19.1 DMM: Měření napětí: +5V (TP49/TP7) 0.0109024554 < 0.5 Pass
20.0.1 TestSW: [ADC_PA0] sense A do var VA = 2264 Pass
20.0.2 TestSW: [ADC_PA1] sense B do var VB = 2266 Pass
20.0.3 TestSW: [ADC_PA2] sense C do var VC = 2266 Pass
20.0.5 Analysis: VA VA[2264] 2210 2340 Pass
20.0.6 Analysis: VB VB[2266] 2210 2340 Pass
20.0.7 Analysis: VC VC[2266] 2210 2340 Pass
20.1 NZ3.1: Měření napětí: Zkrat? 28.00851 > 27.9 Pass
20.1.1 EL1.2: Ověření proudu na zátěži -> Current? 4.989746 4.7 5.3 Pass
20.1.2 TestSW: [ADC_PA0] sense A 2438 2429[VA] 2529[VA] Pass
20.1.3 TestSW: [ADC_PA1] sense B 2096 2001[VB] 2101[VB] Pass
20.1.4 TestSW: [ADC_PA2] sense C 2266 2210 2340 Pass
20.2 NZ3.1: Měření proudu: Kontrola odběru 0.03817476 < 0.06 Pass
20.2.1 EL1.2: Ověření proudu na zátěži -> Current? 4.989708 4.7 5.3 Pass
20.2.2 TestSW: [ADC_PA0] sense A 2090 1999[VA] 2099[VA] Pass
20.2.3 TestSW: [ADC_PA1] sense B 2434 2431[VB] 2531[VB] Pass
20.2.4 TestSW: [ADC_PA2] sense C 2266 2210 2340 Pass
20.3.1 EL1.2: Ověření proudu na zátěži -> Current? 4.989717 4.7 5.3 Pass
20.3.2 TestSW: [ADC_PA0] sense A 2439 2429[VA] 2529[VA] Pass
20.3.3 TestSW: [ADC_PA1] sense B 2269 2210 2340 Pass
20.3.4 TestSW: [ADC_PA2] sense C 2101 2001[VC] 2101[VC] Pass
20.4.1 EL1.2: Ověření proudu na zátěži -> Current? 4.989851 4.7 5.3 Pass
20.4.2 TestSW: [ADC_PA0] sense A 2090 1999[VA] 2099[VA] Pass
20.4.3 TestSW: [ADC_PA1] sense B 2264 2210 2340 Pass
20.4.4 TestSW: [ADC_PA2] sense C 2429 2431[VC] 2531[VC] Fail

Measurements over time

Hover for exact values · drag to zoom · double-click to reset

Readings (6)
DateValueMinMax
2026-07-09 14:56 1.007 10
2026-07-09 15:30 0.987 10
2026-07-09 15:31 0.967 10
2026-07-09 15:32 0.963 10
2026-07-09 15:34 0.946 10
2026-08-11 04:53 0.777 10