2024-09-04 14:18 117 638610491010391758-7082 S0001055 Fail View
2024-09-04 14:45 118 638610506974024329-1251 S0001055 Fail View
2024-09-04 14:56 119 638610513558362910-7362 S0001055 Fail View
2024-09-23 08:48 524 638626708553972701-4829 S0001055 Fail View
2024-12-05 15:08 5423 638690044640990310-1385 S0001055 Fail View
2024-12-05 15:24 5424 638690054090776328-4412 S0001055 Fail View
2025-09-05 11:32 25772 638926615087314204-9021 S0001055 Fail View
2025-11-06 17:25 40594 638980430860671035-2619 S0001055 Fail View
2026-07-09 15:02 77754 639192061011499505-1916 S0001055 Fail View
2026-07-09 15:02 77755 639192061503487785-9949 S0001055 Fail View
2026-07-09 15:05 77756 639192062885456120-7661 S0001055 Fail View
2026-07-09 15:44 77785 639192086590841204-9526 S0001055 Fail View
2026-08-11 04:57 81275 639220209806147612-1733 S0001055 Fail View
2026-08-11 04:57 81276 639220210442951964-9514 S0001055 Fail View
2026-08-11 04:58 81277 639220210750082046-3964 S0001055 Fail View
2026-09-23 05:14 86086 639257372649206631-6164 S0001055 Fail View
2026-09-23 05:15 86087 639257373282538885-1747 S0001055 Fail View
2026-09-23 05:16 86088 639257373681161380-8130 S0001055 Fail View
2026-09-23 05:25 86093 639257379250356497-3217 S0001055 Fail View
2026-09-23 05:32 86098 639257383081671968-1274 S0001055 Fail View
2026-09-23 05:32 86099 639257383338221827-9069 S0001055 Fail View
2026-09-23 05:34 86100 639257384037053788-2817 S0001055 Fail View
2026-09-23 05:36 86101 639257385234025505-4942 S0001055 Fail View
2026-09-23 05:38 86102 639257386543478842-9631 S0001055 Fail View
2026-09-23 05:44 86103 639257390023852283-1687 S0001055 Fail View
2026-09-23 05:45 86104 639257390762551602-3218 S0001055 Fail View

Test 40594

Result
Fail
Date
2025-11-06 17:25
Article
S0001055
ID record
638980430860671035-2619
ID production
49267
Temperature
26.36
Humidity
31.09
Test duration
54
Error ID
358
Error text
TestSW: [ADC_PA1] sense B

Measurement lines

StepNameValueMinMaxResult
0.0 Dekódování a uložení načteného SN 001791579 Pass
0.1 Uložení čísla výrobního příkazu 49267 Pass
0.2 Uložení ID obsluhy 1332 Pass
0.3 Uložení teploty okolí 26.36 Pass
0.4 Uložení vlhkosti okolí 31.09 Pass
0.5 Uložení Id testeru (uloženo na lokálním disku) Vez_Hokami_01-v01.01 Pass
0.6 Uložení id Artiklu (produktové číslo) S0001055 Pass
1.1 DMM: Kontrola hodnoty Odporu (TP6/TP4) 0.88568185 < 10 Pass
1.2 DMM: Kontrola hodnoty Odporu (TP6/TP5) 996.370879 800 1200 Pass
3.1 NZ3.1: Měření napětí: Zkrat? 28.00651 > 27.9 Pass
3.2 NZ3.1: Měření proudu: Kontrola odběru 0.0008558879 < 0.005 Pass
3.3 R11.12: Zapnutí (TP42/TP43) Pass
3.4 NZ3.1: Měření napětí: Zkrat? 28.00851 > 27.9 Pass
3.5 NZ3.1: Měření proudu: Kontrola odběru 0.0241684 < 0.04 Pass
4.1 DMM: Měření napětí: +BATT (TP49/TP44) 27.9635254 27.9 28.1 Pass
4.2 DMM: Měření napětí: +BATT (TP49/TP34) 27.9963984 27.9 28.1 Pass
4.3 DMM: Měření napětí: +12V (TP49/TP46) 11.8447481 11 12.2 Pass
4.4 DMM: Měření napětí: +5V (TP49/TP7) 4.99322753 4.9 5.1 Pass
4.5 DMM: Měření napětí: +3V3 (TP49/TP16) 3.30768113 3.2 3.4 Pass
4.6 DMM: Měření napětí: VDDA +3V3 (TP49/TP2) 3.30768429 3.2 3.4 Pass
4.7 DMM: Měření napětí: (TP49/TP8) 4.67540154 4.57 4.77 Pass
4.8 DMM: Měření napětí: (TP49/TP9) 4.67169275 4.57 4.77 Pass
4.9 DMM: Měření napětí: (TP49/TP10) 4.67081905 4.57 4.77 Pass
5.1 DMM: Měření napětí: (TP49/TP46) 0.531093646 < 1 Pass
5.2 DMM: Měření napětí: (TP49/TP46) 11.7612566 > 11.5 Pass
6.1 R9.12: Vypnutí (TP49/TP28) Pass
7.1 NZ3: Měření napětí: Zkrat? 28.00651 > 27.9 Pass
7.2 NZ3: Měření proudu: Kontrola odběru 0.0250996 < 0.06 Pass
7.3 R0.6: Zapnutí Ext. Programátoru Pass
8.1 TestSw: Ověření komunikace [TYP:AA NAME:eDrive NAME2:TestSW HW:Kolecko v4 SW: Pass
9.1 TestSW: [CHG_SIG (PC14)] = log1? 16384 16384 16384 Pass
9.2 EL1.1: Ověření proudu na zátěži -> Current? 2.015085 1.6 2.8 Pass
9.3 DMM: Měření napětí: Vstup U14 (TP39/TP32) 29.5853839 29 30.1 Pass
9.4 DMM: Měření napětí: Vstup U14 (TP39/TP33) 11.2658291 10.8 11.5 Pass
9.5 DMM: Měření napětí: Vstup U14 (TP39/TP40) 1.61333332 1.5 1.8 Pass
10.1 NZ3.1: Měření napětí: Zkrat? 28.00851 > 27.9 Pass
10.2 NZ3.1: Měření proudu: Kontrola odběru 0.02508192 < 0.06 Pass
10.3 TestSW: [ADC_PA03] 3826 3667 3937 Pass
12.1 TestSW: [PA15] - napájení sense ABC Pass
12.2 TestSW: [HALL_A (PB4)] = log0? 0 0 0 Pass
12.3 TestSW: [HALL_A (PB4)] = log1? 16 16 16 Pass
12.4 TestSW: [HALL_B (PB5)] = log0? 0 0 0 Pass
12.5 TestSW: [HALL_B (PB5)] = log1? 32 32 32 Pass
12.6 TestSW: [HALL_C (PB0)] = log0? 0 0 0 Pass
12.7 TestSW: [HALL_C (PB0)] = log1? 1 1 1 Pass
13.1 TestSW: [CON_ID (PC13)] = log1? 8192 8192 8192 Pass
13.10 TestSW: [BTN_FFWD][ADC_PA6]? 4085 4000 4096 Pass
13.11 TestSW: [BTN_FFWD][ADC_PA6]? 2025 1900 2100 Pass
13.12 TestSW: [BTN_STOP][ADC_PA5]? 4085 4000 4096 Pass
13.13 TestSW: [BTN_STOP][ADC_PA5]? 2027 1900 2100 Pass
13.2 TestSW: [CON_ID (PC13)] = log0? 0 0 0 Pass
13.3 TestSW: [BTN_DRV][PA11] na log1 Pass
13.4 TestSW: [BTN_FWD][ADC_PB1]? 4084 4000 4096 Pass
13.5 TestSW: [BTN_FWD][ADC_PB1]? 2013 1900 2100 Pass
13.6 TestSW: [BTN_REV][ADC_PA4]? 4085 4000 4096 Pass
13.7 TestSW: [BTN_REV][ADC_PA4]? 2027 1900 2100 Pass
13.8 TestSW: [BTN_ULCK][ADC_PA7]? 4085 4000 4096 Pass
13.9 TestSW: [BTN_ULCK][ADC_PA7]? 2028 1900 2100 Pass
14.1 TestSW: [LED1][PB2] na log1 Pass
14.10 DMM: Měření napětí: LED3 (TP49/TP14) 3.30339127 > 3 Pass
14.11 TestSW: [LED3][PB11] na log0 Pass
14.12 DMM: Měření napětí: LED3 (TP49/TP14) 0.0034843917 < 0.1 Pass
14.13 TestSW: [LED4][PB12] na log1 Pass
14.14 DMM: Měření napětí: LED4 (TP49/TP12) 3.30460394 > 3 Pass
14.15 TestSW: [LED4][PB12] na log0 Pass
14.16 DMM: Měření napětí: LED4 (TP49/TP12) 0.00347271033 < 0.1 Pass
14.2 DMM: Měření napětí: LED1 (TP49/TP13) 3.30318914 > 3 Pass
14.3 TestSW: [LED1][PB2] na log0 Pass
14.4 DMM: Měření napětí: LED1 (TP49/TP13) 0.00360864412 < 0.1 Pass
14.5 TestSW: [LED2][PB10] na log1 Pass
14.6 DMM: Měření napětí: LED1 (TP49/TP11) 3.30336615 > 3 Pass
14.7 TestSW: [LED2][PB10] na log0 Pass
14.8 DMM: Měření napětí: LED1 (TP49/TP11) 0.00349444084 < 0.1 Pass
14.9 TestSW: [LED3][PB11] na log1 Pass
15.1 TestSW: ntc 58 49 90 Pass
16.1 DMM: Měření frekvence (TP49/TP55) 19995.1042 19600 20400 Pass
16.2 DMM: Měření frekvence (TP49/TP56) 19995.1004 19600 20400 Pass
16.3 DMM: Měření napětí (TP49/TP52) 14.0030812 13.3 14.7 Pass
17.1 DMM: Měření frekvence (TP49/TP61) 19995.0985 19600 20400 Pass
17.2 DMM: Měření frekvence (TP49/TP62) 19995.1004 19600 20400 Pass
17.3 DMM: Měření napětí (TP49/TP58) 14.0117384 13.3 14.7 Pass
18.1 DMM: Měření frekvence (TP49/TP67) 19995.0967 19600 20400 Pass
18.2 DMM: Měření frekvence (TP49/TP68) 19995.1004 19600 20400 Pass
18.3 DMM: Měření napětí (TP49/TP58) 14.0093901 13.3 14.7 Pass
19.1 DMM: Měření napětí: +5V (TP49/TP7) -0.000426984229 < 0.5 Pass
20.0.1 TestSW: [ADC_PA0] sense A do var VA = 2253 Pass
20.0.2 TestSW: [ADC_PA1] sense B do var VB = 2263 Pass
20.0.3 TestSW: [ADC_PA2] sense C do var VC = 2260 Pass
20.0.5 Analysis: VA VA[2253] 2210 2340 Pass
20.0.6 Analysis: VB VB[2263] 2210 2340 Pass
20.0.7 Analysis: VC VC[2260] 2210 2340 Pass
20.1.3 TestSW: [ADC_PA1] sense B 2100 1998[VB] 2098[VB] Fail
20.1.2 TestSW: [ADC_PA0] sense A 2421 2418[VA] 2518[VA] Pass
20.1.1 EL1.2: Ověření proudu na zátěži -> Current? 4.989853 4.7 5.3 Pass
20.1 NZ3.1: Měření napětí: Zkrat? 28.00851 > 27.9 Pass
20.2 NZ3.1: Měření proudu: Kontrola odběru 0.03769442 < 0.06 Pass

Measurements over time

Hover for exact values · drag to zoom · double-click to reset

Readings (18)
DateValueMinMax
2026-07-09 15:02 1.001 10
2026-07-09 15:02 0.972 10
2026-07-09 15:05 0.962 10
2026-07-09 15:44 0.957 10
2026-08-11 04:57 0.769 10
2026-08-11 04:57 0.759 10
2026-08-11 04:58 0.75 10
2026-09-23 05:14 0.784 10
2026-09-23 05:15 0.777 10
2026-09-23 05:16 0.978 10
2026-09-23 05:25 0.933 10
2026-09-23 05:32 0.802 10
2026-09-23 05:32 0.784 10
2026-09-23 05:34 0.798 10
2026-09-23 05:36 0.777 10
2026-09-23 05:38 0.777 10
2026-09-23 05:44 0.782 10
2026-09-23 05:45 0.782 10