Serial 001791577

Tests18
Approved1
Failures17

Tests over time

Test history

DateMeasurement IDID recordArticleResult
2024-09-04 14:06 112 638610483354289866-8151 S0001055 Fail View
2024-09-04 14:28 113 638610496647410178-6006 S0001055 Fail View
2024-09-23 08:40 522 638626703861855352-9107 S0001055 Fail View
2024-12-05 15:09 5419 638690045347578008-1434 S0001055 Fail View
2024-12-05 15:23 5420 638690053423493414-7160 S0001055 Fail View
2025-09-05 11:31 25770 638926614658429713-5924 S0001055 Fail View
2025-11-06 17:37 40592 638980438088384798-4910 S0001055 Fail View
2026-07-09 15:22 77768 639192073284021356-6117 S0001055 Fail View
2026-07-09 15:23 77769 639192074081305022-8129 S0001055 Fail View
2026-07-09 15:25 77770 639192074775211055-8962 S0001055 Fail View
2026-07-09 15:38 77781 639192082876397769-8704 S0001055 Fail View
2026-07-09 15:40 77782 639192083938420667-9924 S0001055 Fail View
2026-08-11 05:02 81281 639220213635683812-4805 S0001055 Fail View
2026-08-11 05:03 81282 639220213899747345-1973 S0001055 Fail View
2026-09-23 05:17 86089 639257374405244824-8905 S0001055 Fail View
2026-09-23 05:23 86090 639257377966590201-2611 S0001055 Fail View
2026-09-23 05:27 86094 639257379852218894-8357 S0001055 Fail View
2026-09-23 05:28 86095 639257380400504176-7403 S0001055 Pass View

Test 40592

Result
Fail
Date
2025-11-06 17:37
Article
S0001055
ID record
638980438088384798-4910
ID production
49267
Temperature
26.37
Humidity
31.36
Test duration
54
Error ID
371
Error text
TestSW: [ADC_PA1] sense B

Measurement lines

StepNameValueMinMaxResult
0.0 Dekódování a uložení načteného SN 001791577 Pass
0.1 Uložení čísla výrobního příkazu 49267 Pass
0.2 Uložení ID obsluhy 1332 Pass
0.3 Uložení teploty okolí 26.37 Pass
0.4 Uložení vlhkosti okolí 31.36 Pass
0.5 Uložení Id testeru (uloženo na lokálním disku) Vez_Hokami_01-v01.01 Pass
0.6 Uložení id Artiklu (produktové číslo) S0001055 Pass
1.1 DMM: Kontrola hodnoty Odporu (TP6/TP4) 0.924980444 < 10 Pass
1.2 DMM: Kontrola hodnoty Odporu (TP6/TP5) 996.868759 800 1200 Pass
3.1 NZ3.1: Měření napětí: Zkrat? 28.00651 > 27.9 Pass
3.2 NZ3.1: Měření proudu: Kontrola odběru 0.000906007 < 0.005 Pass
3.3 R11.12: Zapnutí (TP42/TP43) Pass
3.4 NZ3.1: Měření napětí: Zkrat? 28.00851 > 27.9 Pass
3.5 NZ3.1: Měření proudu: Kontrola odběru 0.02420376 < 0.04 Pass
4.1 DMM: Měření napětí: +BATT (TP49/TP44) 27.9596674 27.9 28.1 Pass
4.2 DMM: Měření napětí: +BATT (TP49/TP34) 27.996989 27.9 28.1 Pass
4.3 DMM: Měření napětí: +12V (TP49/TP46) 11.9150892 11 12.2 Pass
4.4 DMM: Měření napětí: +5V (TP49/TP7) 4.99505244 4.9 5.1 Pass
4.5 DMM: Měření napětí: +3V3 (TP49/TP16) 3.29328607 3.2 3.4 Pass
4.6 DMM: Měření napětí: VDDA +3V3 (TP49/TP2) 3.293298 3.2 3.4 Pass
4.7 DMM: Měření napětí: (TP49/TP8) 4.67538247 4.57 4.77 Pass
4.8 DMM: Měření napětí: (TP49/TP9) 4.67319396 4.57 4.77 Pass
4.9 DMM: Měření napětí: (TP49/TP10) 4.67334705 4.57 4.77 Pass
5.1 DMM: Měření napětí: (TP49/TP46) 0.524784492 < 1 Pass
5.2 DMM: Měření napětí: (TP49/TP46) 11.829756 > 11.5 Pass
6.1 R9.12: Vypnutí (TP49/TP28) Pass
7.1 NZ3: Měření napětí: Zkrat? 28.00851 > 27.9 Pass
7.2 NZ3: Měření proudu: Kontrola odběru 0.02543261 < 0.06 Pass
7.3 R0.6: Zapnutí Ext. Programátoru Pass
8.1 TestSw: Ověření komunikace [TYP:AA NAME:eDrive NAME2:TestSW HW:Kolecko v4 SW: Pass
9.1 TestSW: [CHG_SIG (PC14)] = log1? 16384 16384 16384 Pass
9.2 EL1.1: Ověření proudu na zátěži -> Current? 2.112677 1.6 2.8 Pass
9.3 DMM: Měření napětí: Vstup U14 (TP39/TP32) 29.5856068 29 30.1 Pass
9.4 DMM: Měření napětí: Vstup U14 (TP39/TP33) 11.2919968 10.8 11.5 Pass
9.5 DMM: Měření napětí: Vstup U14 (TP39/TP40) 1.57407268 1.5 1.8 Pass
10.1 NZ3.1: Měření napětí: Zkrat? 28.00851 > 27.9 Pass
10.2 NZ3.1: Měření proudu: Kontrola odběru 0.0252882 < 0.06 Pass
10.3 TestSW: [ADC_PA03] 3857 3667 3937 Pass
12.1 TestSW: [PA15] - napájení sense ABC Pass
12.2 TestSW: [HALL_A (PB4)] = log0? 0 0 0 Pass
12.3 TestSW: [HALL_A (PB4)] = log1? 16 16 16 Pass
12.4 TestSW: [HALL_B (PB5)] = log0? 0 0 0 Pass
12.5 TestSW: [HALL_B (PB5)] = log1? 32 32 32 Pass
12.6 TestSW: [HALL_C (PB0)] = log0? 0 0 0 Pass
12.7 TestSW: [HALL_C (PB0)] = log1? 1 1 1 Pass
13.1 TestSW: [CON_ID (PC13)] = log1? 8192 8192 8192 Pass
13.10 TestSW: [BTN_FFWD][ADC_PA6]? 4085 4000 4096 Pass
13.11 TestSW: [BTN_FFWD][ADC_PA6]? 2027 1900 2100 Pass
13.12 TestSW: [BTN_STOP][ADC_PA5]? 4085 4000 4096 Pass
13.13 TestSW: [BTN_STOP][ADC_PA5]? 2025 1900 2100 Pass
13.2 TestSW: [CON_ID (PC13)] = log0? 0 0 0 Pass
13.3 TestSW: [BTN_DRV][PA11] na log1 Pass
13.4 TestSW: [BTN_FWD][ADC_PB1]? 4084 4000 4096 Pass
13.5 TestSW: [BTN_FWD][ADC_PB1]? 2012 1900 2100 Pass
13.6 TestSW: [BTN_REV][ADC_PA4]? 4085 4000 4096 Pass
13.7 TestSW: [BTN_REV][ADC_PA4]? 2024 1900 2100 Pass
13.8 TestSW: [BTN_ULCK][ADC_PA7]? 4085 4000 4096 Pass
13.9 TestSW: [BTN_ULCK][ADC_PA7]? 2025 1900 2100 Pass
14.1 TestSW: [LED1][PB2] na log1 Pass
14.10 DMM: Měření napětí: LED3 (TP49/TP14) 3.28895663 > 3 Pass
14.11 TestSW: [LED3][PB11] na log0 Pass
14.12 DMM: Měření napětí: LED3 (TP49/TP14) 0.00349049098 < 0.1 Pass
14.13 TestSW: [LED4][PB12] na log1 Pass
14.14 DMM: Měření napětí: LED4 (TP49/TP12) 3.29023215 > 3 Pass
14.15 TestSW: [LED4][PB12] na log0 Pass
14.16 DMM: Měření napětí: LED4 (TP49/TP12) 0.00347540543 < 0.1 Pass
14.2 DMM: Měření napětí: LED1 (TP49/TP13) 3.28874414 > 3 Pass
14.3 TestSW: [LED1][PB2] na log0 Pass
14.4 DMM: Měření napětí: LED1 (TP49/TP13) 0.00362454023 < 0.1 Pass
14.5 TestSW: [LED2][PB10] na log1 Pass
14.6 DMM: Měření napětí: LED1 (TP49/TP11) 3.28892755 > 3 Pass
14.7 TestSW: [LED2][PB10] na log0 Pass
14.8 DMM: Měření napětí: LED1 (TP49/TP11) 0.00350422727 < 0.1 Pass
14.9 TestSW: [LED3][PB11] na log1 Pass
15.1 TestSW: ntc 56 49 90 Pass
16.1 DMM: Měření frekvence (TP49/TP55) 19995.1612 19600 20400 Pass
16.2 DMM: Měření frekvence (TP49/TP56) 19995.1593 19600 20400 Pass
16.3 DMM: Měření napětí (TP49/TP52) 14.0054076 13.3 14.7 Pass
17.1 DMM: Měření frekvence (TP49/TP61) 19995.1536 19600 20400 Pass
17.2 DMM: Měření frekvence (TP49/TP62) 19995.1588 19600 20400 Pass
17.3 DMM: Měření napětí (TP49/TP58) 14.0056798 13.3 14.7 Pass
18.1 DMM: Měření frekvence (TP49/TP67) 19995.1532 19600 20400 Pass
18.2 DMM: Měření frekvence (TP49/TP68) 19995.1574 19600 20400 Pass
18.3 DMM: Měření napětí (TP49/TP58) 14.0118957 13.3 14.7 Pass
19.1 DMM: Měření napětí: +5V (TP49/TP7) 0.000298874107 < 0.5 Pass
20.0.3 TestSW: [ADC_PA2] sense C do var VC = 2274 Pass
20.0.7 Analysis: VC VC[2274] 2210 2340 Pass
20.0.6 Analysis: VB VB[2261] 2210 2340 Pass
20.0.5 Analysis: VA VA[2270] 2210 2340 Pass
20.0.2 TestSW: [ADC_PA1] sense B do var VB = 2261 Pass
20.0.1 TestSW: [ADC_PA0] sense A do var VA = 2270 Pass
20.1 NZ3.1: Měření napětí: Zkrat? 28.00851 > 27.9 Pass
20.1.1 EL1.2: Ověření proudu na zátěži -> Current? 4.98983 4.7 5.3 Pass
20.1.2 TestSW: [ADC_PA0] sense A 2438 2435[VA] 2535[VA] Pass
20.1.3 TestSW: [ADC_PA1] sense B 2096 1996[VB] 2096[VB] Pass
20.1.4 TestSW: [ADC_PA2] sense C 2274 2210 2340 Pass
20.2 NZ3.1: Měření proudu: Kontrola odběru 0.03774157 < 0.06 Pass
20.2.1 EL1.2: Ověření proudu na zátěži -> Current? 4.989707 4.7 5.3 Pass
20.2.2 TestSW: [ADC_PA0] sense A 2103 2005[VA] 2105[VA] Pass
20.2.3 TestSW: [ADC_PA1] sense B 2424 2426[VB] 2526[VB] Fail

Measurements over time

Hover for exact values · drag to zoom · double-click to reset

Readings (11)
DateValueMinMax
2026-07-09 15:22 0.985 10
2026-07-09 15:23 0.96 10
2026-07-09 15:25 0.945 10
2026-07-09 15:38 0.977 10
2026-07-09 15:40 0.945 10
2026-08-11 05:02 0.974 10
2026-08-11 05:03 0.832 10
2026-09-23 05:17 1.19 10
2026-09-23 05:23 1.088 10
2026-09-23 05:27 0.905 10
2026-09-23 05:28 0.993 10