DateMeasurement IDID recordArticleResult
2024-09-09 09:17 311 638614630285353655-2578 S0001055 Fail View
2024-09-09 09:56 312 638614653393638359-1604 S0001055 Fail View
2024-09-09 10:05 313 638614658961195391-7476 S0001055 Fail View
2024-09-23 09:19 515 638626727057512382-3969 S0001055 Fail View
2024-12-05 14:59 5411 638690039139202765-8350 S0001055 Fail View
2024-12-05 15:30 5412 638690057708714188-6156 S0001055 Fail View
2025-09-05 11:23 25766 638926609805697372-8443 S0001055 Fail View
2025-11-06 17:39 40590 638980439426395464-4368 S0001055 Fail View
2026-07-09 15:15 77762 639192068747640023-1240 S0001055 Fail View
2026-07-09 15:16 77763 639192069420887805-8903 S0001055 Fail View
2026-07-09 15:17 77764 639192070059883446-2385 S0001055 Pass View

Test 40590

Result
Fail
Date
2025-11-06 17:39
Article
S0001055
ID record
638980439426395464-4368
ID production
49267
Temperature
26.37
Humidity
31.36
Test duration
55
Error ID
398
Error text
TestSW: [ADC_PA2] sense C

Measurement lines

StepNameValueMinMaxResult
0.0 Dekódování a uložení načteného SN 001791562 Pass
0.1 Uložení čísla výrobního příkazu 49267 Pass
0.2 Uložení ID obsluhy 1332 Pass
0.3 Uložení teploty okolí 26.37 Pass
0.4 Uložení vlhkosti okolí 31.36 Pass
0.5 Uložení Id testeru (uloženo na lokálním disku) Vez_Hokami_01-v01.01 Pass
0.6 Uložení id Artiklu (produktové číslo) S0001055 Pass
1.1 DMM: Kontrola hodnoty Odporu (TP6/TP4) 0.71761143 < 10 Pass
1.2 DMM: Kontrola hodnoty Odporu (TP6/TP5) 1000.06396 800 1200 Pass
3.1 NZ3.1: Měření napětí: Zkrat? 28.00851 > 27.9 Pass
3.2 NZ3.1: Měření proudu: Kontrola odběru 0.0008234952 < 0.005 Pass
3.3 R11.12: Zapnutí (TP42/TP43) Pass
3.4 NZ3.1: Měření napětí: Zkrat? 28.00851 > 27.9 Pass
3.5 NZ3.1: Měření proudu: Kontrola odběru 0.02414777 < 0.04 Pass
4.1 DMM: Měření napětí: +BATT (TP49/TP44) 27.9683236 27.9 28.1 Pass
4.2 DMM: Měření napětí: +BATT (TP49/TP34) 27.9969668 27.9 28.1 Pass
4.3 DMM: Měření napětí: +12V (TP49/TP46) 11.95098 11 12.2 Pass
4.4 DMM: Měření napětí: +5V (TP49/TP7) 4.98118793 4.9 5.1 Pass
4.5 DMM: Měření napětí: +3V3 (TP49/TP16) 3.30831037 3.2 3.4 Pass
4.6 DMM: Měření napětí: VDDA +3V3 (TP49/TP2) 3.30831685 3.2 3.4 Pass
4.7 DMM: Měření napětí: (TP49/TP8) 4.66292294 4.57 4.77 Pass
4.8 DMM: Měření napětí: (TP49/TP9) 4.6592855 4.57 4.77 Pass
4.9 DMM: Měření napětí: (TP49/TP10) 4.65893167 4.57 4.77 Pass
5.1 DMM: Měření napětí: (TP49/TP46) 0.50996746 < 1 Pass
5.2 DMM: Měření napětí: (TP49/TP46) 11.8642902 > 11.5 Pass
6.1 R9.12: Vypnutí (TP49/TP28) Pass
7.1 NZ3: Měření napětí: Zkrat? 28.00851 > 27.9 Pass
7.2 NZ3: Měření proudu: Kontrola odběru 0.02580979 < 0.06 Pass
7.3 R0.6: Zapnutí Ext. Programátoru Pass
8.1 TestSw: Ověření komunikace [TYP:AA NAME:eDrive NAME2:TestSW HW:Kolecko v4 SW: Pass
9.1 TestSW: [CHG_SIG (PC14)] = log1? 16384 16384 16384 Pass
9.2 EL1.1: Ověření proudu na zátěži -> Current? 2.102492 1.6 2.8 Pass
9.3 DMM: Měření napětí: Vstup U14 (TP39/TP32) 29.5917522 29 30.1 Pass
9.4 DMM: Měření napětí: Vstup U14 (TP39/TP33) 11.2945512 10.8 11.5 Pass
9.5 DMM: Měření napětí: Vstup U14 (TP39/TP40) 1.5950855 1.5 1.8 Pass
10.1 NZ3.1: Měření napětí: Zkrat? 28.00851 > 27.9 Pass
10.2 NZ3.1: Měření proudu: Kontrola odběru 0.02578622 < 0.06 Pass
10.3 TestSW: [ADC_PA03] 3846 3667 3937 Pass
12.1 TestSW: [PA15] - napájení sense ABC Pass
12.2 TestSW: [HALL_A (PB4)] = log0? 0 0 0 Pass
12.3 TestSW: [HALL_A (PB4)] = log1? 16 16 16 Pass
12.4 TestSW: [HALL_B (PB5)] = log0? 0 0 0 Pass
12.5 TestSW: [HALL_B (PB5)] = log1? 32 32 32 Pass
12.6 TestSW: [HALL_C (PB0)] = log0? 0 0 0 Pass
12.7 TestSW: [HALL_C (PB0)] = log1? 1 1 1 Pass
13.1 TestSW: [CON_ID (PC13)] = log1? 8192 8192 8192 Pass
13.10 TestSW: [BTN_FFWD][ADC_PA6]? 4085 4000 4096 Pass
13.11 TestSW: [BTN_FFWD][ADC_PA6]? 2025 1900 2100 Pass
13.12 TestSW: [BTN_STOP][ADC_PA5]? 4085 4000 4096 Pass
13.13 TestSW: [BTN_STOP][ADC_PA5]? 2025 1900 2100 Pass
13.2 TestSW: [CON_ID (PC13)] = log0? 0 0 0 Pass
13.3 TestSW: [BTN_DRV][PA11] na log1 Pass
13.4 TestSW: [BTN_FWD][ADC_PB1]? 4084 4000 4096 Pass
13.5 TestSW: [BTN_FWD][ADC_PB1]? 2014 1900 2100 Pass
13.6 TestSW: [BTN_REV][ADC_PA4]? 4085 4000 4096 Pass
13.7 TestSW: [BTN_REV][ADC_PA4]? 2028 1900 2100 Pass
13.8 TestSW: [BTN_ULCK][ADC_PA7]? 4085 4000 4096 Pass
13.9 TestSW: [BTN_ULCK][ADC_PA7]? 2029 1900 2100 Pass
14.1 TestSW: [LED1][PB2] na log1 Pass
14.10 DMM: Měření napětí: LED3 (TP49/TP14) 3.3039383 > 3 Pass
14.11 TestSW: [LED3][PB11] na log0 Pass
14.12 DMM: Měření napětí: LED3 (TP49/TP14) 0.00351201866 < 0.1 Pass
14.13 TestSW: [LED4][PB12] na log1 Pass
14.14 DMM: Měření napětí: LED4 (TP49/TP12) 3.30513546 > 3 Pass
14.15 TestSW: [LED4][PB12] na log0 Pass
14.16 DMM: Měření napětí: LED4 (TP49/TP12) 0.00349735155 < 0.1 Pass
14.2 DMM: Měření napětí: LED1 (TP49/TP13) 3.30376929 > 3 Pass
14.3 TestSW: [LED1][PB2] na log0 Pass
14.4 DMM: Měření napětí: LED1 (TP49/TP13) 0.00361714313 < 0.1 Pass
14.5 TestSW: [LED2][PB10] na log1 Pass
14.6 DMM: Měření napětí: LED1 (TP49/TP11) 3.30391801 > 3 Pass
14.7 TestSW: [LED2][PB10] na log0 Pass
14.8 DMM: Měření napětí: LED1 (TP49/TP11) 0.00352233462 < 0.1 Pass
14.9 TestSW: [LED3][PB11] na log1 Pass
15.1 TestSW: ntc 56 49 90 Pass
16.1 DMM: Měření frekvence (TP49/TP55) 19995.0985 19600 20400 Pass
16.2 DMM: Měření frekvence (TP49/TP56) 19995.0967 19600 20400 Pass
16.3 DMM: Měření napětí (TP49/TP52) 14.0064707 13.3 14.7 Pass
17.1 DMM: Měření frekvence (TP49/TP61) 19995.0929 19600 20400 Pass
17.2 DMM: Měření frekvence (TP49/TP62) 19995.0971 19600 20400 Pass
17.3 DMM: Měření napětí (TP49/TP58) 14.01032 13.3 14.7 Pass
18.1 DMM: Měření frekvence (TP49/TP67) 19995.0929 19600 20400 Pass
18.2 DMM: Měření frekvence (TP49/TP68) 19995.0967 19600 20400 Pass
18.3 DMM: Měření napětí (TP49/TP58) 14.0006201 13.3 14.7 Pass
19.1 DMM: Měření napětí: +5V (TP49/TP7) -0.000405888399 < 0.5 Pass
20.0.1 TestSW: [ADC_PA0] sense A do var VA = 2260 Pass
20.0.2 TestSW: [ADC_PA1] sense B do var VB = 2257 Pass
20.0.3 TestSW: [ADC_PA2] sense C do var VC = 2260 Pass
20.0.5 Analysis: VA VA[2260] 2210 2340 Pass
20.0.6 Analysis: VB VB[2257] 2210 2340 Pass
20.0.7 Analysis: VC VC[2260] 2210 2340 Pass
20.1 NZ3.1: Měření napětí: Zkrat? 28.00851 > 27.9 Pass
20.1.1 EL1.2: Ověření proudu na zátěži -> Current? 4.989789 4.7 5.3 Pass
20.1.2 TestSW: [ADC_PA0] sense A 2428 2425[VA] 2525[VA] Pass
20.1.3 TestSW: [ADC_PA1] sense B 2089 1992[VB] 2092[VB] Pass
20.1.4 TestSW: [ADC_PA2] sense C 2259 2210 2340 Pass
20.2 NZ3.1: Měření proudu: Kontrola odběru 0.03811876 < 0.06 Pass
20.2.1 EL1.2: Ověření proudu na zátěži -> Current? 4.989692 4.7 5.3 Pass
20.2.2 TestSW: [ADC_PA0] sense A 2091 1995[VA] 2095[VA] Pass
20.2.3 TestSW: [ADC_PA1] sense B 2425 2422[VB] 2522[VB] Pass
20.2.4 TestSW: [ADC_PA2] sense C 2259 2210 2340 Pass
20.3.1 EL1.2: Ověření proudu na zátěži -> Current? 4.989769 4.7 5.3 Pass
20.3.2 TestSW: [ADC_PA0] sense A 2428 2425[VA] 2525[VA] Pass
20.3.3 TestSW: [ADC_PA1] sense B 2259 2210 2340 Pass
20.3.4 TestSW: [ADC_PA2] sense C 2095 1995[VC] 2095[VC] Pass
20.4.1 EL1.2: Ověření proudu na zátěži -> Current? 4.9898 4.7 5.3 Pass
20.4.2 TestSW: [ADC_PA0] sense A 2091 1995[VA] 2095[VA] Pass
20.4.3 TestSW: [ADC_PA1] sense B 2255 2210 2340 Pass
20.4.4 TestSW: [ADC_PA2] sense C 2424 2425[VC] 2525[VC] Fail

Measurements over time

Hover for exact values · drag to zoom · double-click to reset

Readings (3)
DateValueMinMax
2026-07-09 15:15 1.011 10
2026-07-09 15:16 0.971 10
2026-07-09 15:17 0.965 10