Testing Portal everyone (auth disabled)

Serial lookup

Search a serial number to see its full test history.

Serial 001791556

Tests11
Approved1
Failures10

Tests over time

Test history

DateMeasurement IDID recordArticleResult
2024-09-09 07:34 303 638614567935250894-9843 S0001055 Fail View
2024-09-09 07:47 304 638614576174253204-4001 S0001055 Fail View
2024-09-23 09:04 513 638626718023733530-4255 S0001055 Fail View
2024-12-05 15:11 5407 638690046054650320-1766 S0001055 Fail View
2024-12-05 15:33 5408 638690059428179741-4029 S0001055 Fail View
2025-09-05 11:20 25764 638926607643503145-2703 S0001055 Fail View
2025-11-06 17:34 40588 638980436179135332-9537 S0001055 Fail View
2026-07-09 14:55 77749 639192056731863485-6591 S0001055 Fail View
2026-07-09 15:26 77771 639192075495091633-7038 S0001055 Fail View
2026-08-11 04:53 81273 639220208058021312-8806 S0001055 Fail View
2026-08-11 04:54 81274 639220208321411482-3530 S0001055 Pass View

Test 40588

Result
Fail
Date
2025-11-06 17:34
Article
S0001055
ID record
638980436179135332-9537
ID production
49267
Temperature
26.4
Humidity
31.29
Test duration
54
Error ID
385
Error text
TestSW: [ADC_PA2] sense C

Measurement lines

StepNameValueMinMaxResult
0.0 Dekódování a uložení načteného SN 001791556 Pass
0.1 Uložení čísla výrobního příkazu 49267 Pass
0.2 Uložení ID obsluhy 1332 Pass
0.3 Uložení teploty okolí 26.4 Pass
0.4 Uložení vlhkosti okolí 31.29 Pass
0.5 Uložení Id testeru (uloženo na lokálním disku) Vez_Hokami_01-v01.01 Pass
0.6 Uložení id Artiklu (produktové číslo) S0001055 Pass
1.1 DMM: Kontrola hodnoty Odporu (TP6/TP4) 0.700884588 < 10 Pass
1.2 DMM: Kontrola hodnoty Odporu (TP6/TP5) 999.297409 800 1200 Pass
3.1 NZ3.1: Měření napětí: Zkrat? 28.00851 > 27.9 Pass
3.2 NZ3.1: Měření proudu: Kontrola odběru 0.0008558879 < 0.005 Pass
3.3 R11.12: Zapnutí (TP42/TP43) Pass
3.4 NZ3.1: Měření napětí: Zkrat? 28.00851 > 27.9 Pass
3.5 NZ3.1: Měření proudu: Kontrola odběru 0.02378825 < 0.04 Pass
4.1 DMM: Měření napětí: +BATT (TP49/TP44) 27.9700321 27.9 28.1 Pass
4.2 DMM: Měření napětí: +BATT (TP49/TP34) 27.9970019 27.9 28.1 Pass
4.3 DMM: Měření napětí: +12V (TP49/TP46) 11.7482467 11 12.2 Pass
4.4 DMM: Měření napětí: +5V (TP49/TP7) 4.98891129 4.9 5.1 Pass
4.5 DMM: Měření napětí: +3V3 (TP49/TP16) 3.2888482 3.2 3.4 Pass
4.6 DMM: Měření napětí: VDDA +3V3 (TP49/TP2) 3.2888625 3.2 3.4 Pass
4.7 DMM: Měření napětí: (TP49/TP8) 4.66924596 4.57 4.77 Pass
4.8 DMM: Měření napětí: (TP49/TP9) 4.66683978 4.57 4.77 Pass
4.9 DMM: Měření napětí: (TP49/TP10) 4.66729622 4.57 4.77 Pass
5.1 DMM: Měření napětí: (TP49/TP46) 0.515994015 < 1 Pass
5.2 DMM: Měření napětí: (TP49/TP46) 11.662024 > 11.5 Pass
6.1 R9.12: Vypnutí (TP49/TP28) Pass
7.1 NZ3: Měření napětí: Zkrat? 28.00851 > 27.9 Pass
7.2 NZ3: Měření proudu: Kontrola odběru 0.02502888 < 0.06 Pass
7.3 R0.6: Zapnutí Ext. Programátoru Pass
8.1 TestSw: Ověření komunikace [TYP:AA NAME:eDrive NAME2:TestSW HW:Kolecko v4 SW: Pass
9.1 TestSW: [CHG_SIG (PC14)] = log1? 16384 16384 16384 Pass
9.2 EL1.1: Ověření proudu na zátěži -> Current? 1.999228 1.6 2.8 Pass
9.3 DMM: Měření napětí: Vstup U14 (TP39/TP32) 29.6031395 29 30.1 Pass
9.4 DMM: Měření napětí: Vstup U14 (TP39/TP33) 11.237538 10.8 11.5 Pass
9.5 DMM: Měření napětí: Vstup U14 (TP39/TP40) 1.60374795 1.5 1.8 Pass
10.1 NZ3.1: Měření napětí: Zkrat? 28.00851 > 27.9 Pass
10.2 NZ3.1: Měření proudu: Kontrola odběru 0.02511433 < 0.06 Pass
10.3 TestSW: [ADC_PA03] 3853 3667 3937 Pass
12.1 TestSW: [PA15] - napájení sense ABC Pass
12.2 TestSW: [HALL_A (PB4)] = log0? 0 0 0 Pass
12.3 TestSW: [HALL_A (PB4)] = log1? 16 16 16 Pass
12.4 TestSW: [HALL_B (PB5)] = log0? 0 0 0 Pass
12.5 TestSW: [HALL_B (PB5)] = log1? 32 32 32 Pass
12.6 TestSW: [HALL_C (PB0)] = log0? 0 0 0 Pass
12.7 TestSW: [HALL_C (PB0)] = log1? 1 1 1 Pass
13.1 TestSW: [CON_ID (PC13)] = log1? 8192 8192 8192 Pass
13.10 TestSW: [BTN_FFWD][ADC_PA6]? 4082 4000 4096 Pass
13.11 TestSW: [BTN_FFWD][ADC_PA6]? 2023 1900 2100 Pass
13.12 TestSW: [BTN_STOP][ADC_PA5]? 4082 4000 4096 Pass
13.13 TestSW: [BTN_STOP][ADC_PA5]? 2021 1900 2100 Pass
13.2 TestSW: [CON_ID (PC13)] = log0? 0 0 0 Pass
13.3 TestSW: [BTN_DRV][PA11] na log1 Pass
13.4 TestSW: [BTN_FWD][ADC_PB1]? 4081 4000 4096 Pass
13.5 TestSW: [BTN_FWD][ADC_PB1]? 2009 1900 2100 Pass
13.6 TestSW: [BTN_REV][ADC_PA4]? 4082 4000 4096 Pass
13.7 TestSW: [BTN_REV][ADC_PA4]? 2023 1900 2100 Pass
13.8 TestSW: [BTN_ULCK][ADC_PA7]? 4082 4000 4096 Pass
13.9 TestSW: [BTN_ULCK][ADC_PA7]? 2022 1900 2100 Pass
14.1 TestSW: [LED1][PB2] na log1 Pass
14.10 DMM: Měření napětí: LED3 (TP49/TP14) 3.28476022 > 3 Pass
14.11 TestSW: [LED3][PB11] na log0 Pass
14.12 DMM: Měření napětí: LED3 (TP49/TP14) 0.00347623392 < 0.1 Pass
14.13 TestSW: [LED4][PB12] na log1 Pass
14.14 DMM: Měření napětí: LED4 (TP49/TP12) 3.28608475 > 3 Pass
14.15 TestSW: [LED4][PB12] na log0 Pass
14.16 DMM: Měření napětí: LED4 (TP49/TP12) 0.00346396679 < 0.1 Pass
14.2 DMM: Měření napětí: LED1 (TP49/TP13) 3.284667 > 3 Pass
14.3 TestSW: [LED1][PB2] na log0 Pass
14.4 DMM: Měření napětí: LED1 (TP49/TP13) 0.00356188401 < 0.1 Pass
14.5 TestSW: [LED2][PB10] na log1 Pass
14.6 DMM: Měření napětí: LED1 (TP49/TP11) 3.28481425 > 3 Pass
14.7 TestSW: [LED2][PB10] na log0 Pass
14.8 DMM: Měření napětí: LED1 (TP49/TP11) 0.00346145311 < 0.1 Pass
14.9 TestSW: [LED3][PB11] na log1 Pass
15.1 TestSW: ntc 58 49 90 Pass
16.1 DMM: Měření frekvence (TP49/TP55) 19995.0293 19600 20400 Pass
16.2 DMM: Měření frekvence (TP49/TP56) 19995.0274 19600 20400 Pass
16.3 DMM: Měření napětí (TP49/TP52) 14.0069619 13.3 14.7 Pass
17.1 DMM: Měření frekvence (TP49/TP61) 19995.0194 19600 20400 Pass
17.2 DMM: Měření frekvence (TP49/TP62) 19995.0232 19600 20400 Pass
17.3 DMM: Měření napětí (TP49/TP58) 14.0056265 13.3 14.7 Pass
18.1 DMM: Měření frekvence (TP49/TP67) 19995.0194 19600 20400 Pass
18.2 DMM: Měření frekvence (TP49/TP68) 19995.0251 19600 20400 Pass
18.3 DMM: Měření napětí (TP49/TP58) 14.0094734 13.3 14.7 Pass
19.1 DMM: Měření napětí: +5V (TP49/TP7) 0.0117375743 < 0.5 Pass
20.0.1 TestSW: [ADC_PA0] sense A do var VA = 2271 Pass
20.0.2 TestSW: [ADC_PA1] sense B do var VB = 2264 Pass
20.0.3 TestSW: [ADC_PA2] sense C do var VC = 2274 Pass
20.0.5 Analysis: VA VA[2271] 2210 2340 Pass
20.0.6 Analysis: VB VB[2264] 2210 2340 Pass
20.0.7 Analysis: VC VC[2274] 2210 2340 Pass
20.1 NZ3.1: Měření napětí: Zkrat? 28.00851 > 27.9 Pass
20.1.1 EL1.2: Ověření proudu na zátěži -> Current? 4.989833 4.7 5.3 Pass
20.1.2 TestSW: [ADC_PA0] sense A 2441 2436[VA] 2536[VA] Pass
20.1.3 TestSW: [ADC_PA1] sense B 2096 1999[VB] 2099[VB] Pass
20.1.4 TestSW: [ADC_PA2] sense C 2274 2210 2340 Pass
20.2 NZ3.1: Měření proudu: Kontrola odběru 0.03744394 < 0.06 Pass
20.2.1 EL1.2: Ověření proudu na zátěži -> Current? 4.989734 4.7 5.3 Pass
20.2.2 TestSW: [ADC_PA0] sense A 2100 2006[VA] 2106[VA] Pass
20.2.3 TestSW: [ADC_PA1] sense B 2430 2429[VB] 2529[VB] Pass
20.2.4 TestSW: [ADC_PA2] sense C 2274 2210 2340 Pass
20.3.1 EL1.2: Ověření proudu na zátěži -> Current? 4.989725 4.7 5.3 Pass
20.3.2 TestSW: [ADC_PA0] sense A 2441 2436[VA] 2536[VA] Pass
20.3.3 TestSW: [ADC_PA1] sense B 2267 2210 2340 Pass
20.3.4 TestSW: [ADC_PA2] sense C 2110 2009[VC] 2109[VC] Fail

Measurements over time

Hover for exact values · drag to zoom · double-click to reset

Readings (4)
DateValueMinMax
2026-07-09 14:55 1.006 10
2026-07-09 15:26 0.963 10
2026-08-11 04:53 0.84 10
2026-08-11 04:54 0.802 10