Testing Portal everyone (auth disabled)

Serial lookup

Search a serial number to see its full test history.

Serial 000797152

Tests14
Approved1
Failures13

Tests over time

Test history

DateMeasurement IDID recordArticleResult
2024-09-19 12:33 346 638623387300018643-6041 S0001055 Fail View
2024-09-19 12:41 347 638623392208302988-5790 S0001055 Fail View
2024-09-19 12:42 348 638623392950854439-6507 S0001055 Fail View
2024-12-05 14:32 5333 638690022816728924-1879 S0001055 Fail View
2024-12-05 14:39 5334 638690027102964199-6831 S0001055 Fail View
2025-07-16 11:29 22214 638882549124900138-9377 S0001055 Fail View
2025-07-16 11:30 22215 638882549876914365-8935 S0001055 Fail View
2025-07-16 11:32 22216 638882550717837208-7445 S0001055 Fail View
2025-07-16 11:34 22217 638882551977991212-6980 S0001055 Fail View
2025-07-16 11:35 22218 638882552795311921-6176 S0001055 Pass View
2025-11-06 16:54 40578 638980412336203268-1311 S0001055 Fail View
2026-07-09 16:50 77822 639192125584608437-3885 S0001055 Fail View
2026-07-09 16:51 77823 639192126238100578-2421 S0001055 Fail View
2026-07-09 16:52 77824 639192126896309818-4343 S0001055 Fail View

Test 40578

Result
Fail
Date
2025-11-06 16:54
Article
S0001055
ID record
638980412336203268-1311
ID production
46078
Temperature
26.25
Humidity
31.03
Test duration
54
Error ID
371
Error text
TestSW: [ADC_PA1] sense B

Measurement lines

StepNameValueMinMaxResult
0.0 Dekódování a uložení načteného SN 000797152 Pass
0.1 Uložení čísla výrobního příkazu 46078 Pass
0.2 Uložení ID obsluhy 1332 Pass
0.3 Uložení teploty okolí 26.25 Pass
0.4 Uložení vlhkosti okolí 31.03 Pass
0.5 Uložení Id testeru (uloženo na lokálním disku) Vez_Hokami_01-v01.01 Pass
0.6 Uložení id Artiklu (produktové číslo) S0001055 Pass
1.1 DMM: Kontrola hodnoty Odporu (TP6/TP4) 0.872940893 < 10 Pass
1.2 DMM: Kontrola hodnoty Odporu (TP6/TP5) 999.30082 800 1200 Pass
3.1 NZ3.1: Měření napětí: Zkrat? 28.00651 > 27.9 Pass
3.2 NZ3.1: Měření proudu: Kontrola odběru 0.000596588 < 0.005 Pass
3.3 R11.12: Zapnutí (TP42/TP43) Pass
3.4 NZ3.1: Měření napětí: Zkrat? 28.00851 > 27.9 Pass
3.5 NZ3.1: Měření proudu: Kontrola odběru 0.02429806 < 0.04 Pass
4.1 DMM: Měření napětí: +BATT (TP49/TP44) 27.960743 27.9 28.1 Pass
4.2 DMM: Měření napětí: +BATT (TP49/TP34) 27.9963791 27.9 28.1 Pass
4.3 DMM: Měření napětí: +12V (TP49/TP46) 11.8983402 11 12.2 Pass
4.4 DMM: Měření napětí: +5V (TP49/TP7) 5.01613548 4.9 5.1 Pass
4.5 DMM: Měření napětí: +3V3 (TP49/TP16) 3.30380396 3.2 3.4 Pass
4.6 DMM: Měření napětí: VDDA +3V3 (TP49/TP2) 3.30382892 3.2 3.4 Pass
4.7 DMM: Měření napětí: (TP49/TP8) 4.69522954 4.57 4.77 Pass
4.8 DMM: Měření napětí: (TP49/TP9) 4.69217631 4.57 4.77 Pass
4.9 DMM: Měření napětí: (TP49/TP10) 4.69206946 4.57 4.77 Pass
5.1 DMM: Měření napětí: (TP49/TP46) 0.518521411 < 1 Pass
5.2 DMM: Měření napětí: (TP49/TP46) 11.8238867 > 11.5 Pass
6.1 R9.12: Vypnutí (TP49/TP28) Pass
7.1 NZ3: Měření napětí: Zkrat? 28.00651 > 27.9 Pass
7.2 NZ3: Měření proudu: Kontrola odběru 0.01200973 < 0.06 Pass
7.3 R0.6: Zapnutí Ext. Programátoru Pass
8.1 TestSw: Ověření komunikace [TYP:AA NAME:eDrive NAME2:TestSW HW:Kolecko v4 SW: Pass
9.1 TestSW: [CHG_SIG (PC14)] = log1? 16384 16384 16384 Pass
9.2 EL1.1: Ověření proudu na zátěži -> Current? 2.066264 1.6 2.8 Pass
9.3 DMM: Měření napětí: Vstup U14 (TP39/TP32) 29.5914094 29 30.1 Pass
9.4 DMM: Měření napětí: Vstup U14 (TP39/TP33) 11.335822 10.8 11.5 Pass
9.5 DMM: Měření napětí: Vstup U14 (TP39/TP40) 1.62789276 1.5 1.8 Pass
10.1 NZ3.1: Měření napětí: Zkrat? 28.00851 > 27.9 Pass
10.2 NZ3.1: Měření proudu: Kontrola odběru 0.02492279 < 0.06 Pass
10.3 TestSW: [ADC_PA03] 3861 3667 3937 Pass
12.1 TestSW: [PA15] - napájení sense ABC Pass
12.2 TestSW: [HALL_A (PB4)] = log0? 0 0 0 Pass
12.3 TestSW: [HALL_A (PB4)] = log1? 16 16 16 Pass
12.4 TestSW: [HALL_B (PB5)] = log0? 0 0 0 Pass
12.5 TestSW: [HALL_B (PB5)] = log1? 32 32 32 Pass
12.6 TestSW: [HALL_C (PB0)] = log0? 0 0 0 Pass
12.7 TestSW: [HALL_C (PB0)] = log1? 1 1 1 Pass
13.1 TestSW: [CON_ID (PC13)] = log1? 8192 8192 8192 Pass
13.10 TestSW: [BTN_FFWD][ADC_PA6]? 4086 4000 4096 Pass
13.11 TestSW: [BTN_FFWD][ADC_PA6]? 2000 1900 2100 Pass
13.12 TestSW: [BTN_STOP][ADC_PA5]? 4086 4000 4096 Pass
13.13 TestSW: [BTN_STOP][ADC_PA5]? 1999 1900 2100 Pass
13.2 TestSW: [CON_ID (PC13)] = log0? 0 0 0 Pass
13.3 TestSW: [BTN_DRV][PA11] na log1 Pass
13.4 TestSW: [BTN_FWD][ADC_PB1]? 4085 4000 4096 Pass
13.5 TestSW: [BTN_FWD][ADC_PB1]? 2014 1900 2100 Pass
13.6 TestSW: [BTN_REV][ADC_PA4]? 4085 4000 4096 Pass
13.7 TestSW: [BTN_REV][ADC_PA4]? 2008 1900 2100 Pass
13.8 TestSW: [BTN_ULCK][ADC_PA7]? 4085 4000 4096 Pass
13.9 TestSW: [BTN_ULCK][ADC_PA7]? 2007 1900 2100 Pass
14.1 TestSW: [LED1][PB2] na log1 Pass
14.10 DMM: Měření napětí: LED3 (TP49/TP14) 3.30002867 > 3 Pass
14.11 TestSW: [LED3][PB11] na log0 Pass
14.12 DMM: Měření napětí: LED3 (TP49/TP14) 0.00341473331 < 0.1 Pass
14.13 TestSW: [LED4][PB12] na log1 Pass
14.14 DMM: Měření napětí: LED4 (TP49/TP12) 3.30134751 > 3 Pass
14.15 TestSW: [LED4][PB12] na log0 Pass
14.16 DMM: Měření napětí: LED4 (TP49/TP12) 0.00340288132 < 0.1 Pass
14.2 DMM: Měření napětí: LED1 (TP49/TP13) 3.29978797 > 3 Pass
14.3 TestSW: [LED1][PB2] na log0 Pass
14.4 DMM: Měření napětí: LED1 (TP49/TP13) 0.0035190985 < 0.1 Pass
14.5 TestSW: [LED2][PB10] na log1 Pass
14.6 DMM: Měření napětí: LED1 (TP49/TP11) 3.29995909 > 3 Pass
14.7 TestSW: [LED2][PB10] na log0 Pass
14.8 DMM: Měření napětí: LED1 (TP49/TP11) 0.00342417925 < 0.1 Pass
14.9 TestSW: [LED3][PB11] na log1 Pass
15.1 TestSW: ntc 57 49 90 Pass
16.1 DMM: Měření frekvence (TP49/TP55) 19995.2172 19600 20400 Pass
16.2 DMM: Měření frekvence (TP49/TP56) 19995.2172 19600 20400 Pass
16.3 DMM: Měření napětí (TP49/TP52) 14.0075647 13.3 14.7 Pass
17.1 DMM: Měření frekvence (TP49/TP61) 19995.2115 19600 20400 Pass
17.2 DMM: Měření frekvence (TP49/TP62) 19995.2172 19600 20400 Pass
17.3 DMM: Měření napětí (TP49/TP58) 14.0062284 13.3 14.7 Pass
18.1 DMM: Měření frekvence (TP49/TP67) 19995.2115 19600 20400 Pass
18.2 DMM: Měření frekvence (TP49/TP68) 19995.2153 19600 20400 Pass
18.3 DMM: Měření napětí (TP49/TP58) 14.0079584 13.3 14.7 Pass
19.1 DMM: Měření napětí: +5V (TP49/TP7) 0.012506034 < 0.5 Pass
20.0.3 TestSW: [ADC_PA2] sense C do var VC = 2281 Pass
20.0.7 Analysis: VC VC[2281] 2210 2340 Pass
20.0.6 Analysis: VB VB[2270] 2210 2340 Pass
20.0.5 Analysis: VA VA[2270] 2210 2340 Pass
20.0.2 TestSW: [ADC_PA1] sense B do var VB = 2270 Pass
20.0.1 TestSW: [ADC_PA0] sense A do var VA = 2270 Pass
20.1 NZ3.1: Měření napětí: Zkrat? 28.00851 > 27.9 Pass
20.1.1 EL1.2: Ověření proudu na zátěži -> Current? 4.989682 4.7 5.3 Pass
20.1.2 TestSW: [ADC_PA0] sense A 2443 2435[VA] 2535[VA] Pass
20.1.3 TestSW: [ADC_PA1] sense B 2104 2005[VB] 2105[VB] Pass
20.1.4 TestSW: [ADC_PA2] sense C 2281 2210 2340 Pass
20.2 NZ3.1: Měření proudu: Kontrola odběru 0.03807751 < 0.06 Pass
20.2.1 EL1.2: Ověření proudu na zátěži -> Current? 4.98986 4.7 5.3 Pass
20.2.2 TestSW: [ADC_PA0] sense A 2097 2005[VA] 2105[VA] Pass
20.2.3 TestSW: [ADC_PA1] sense B 2434 2435[VB] 2535[VB] Fail

Measurements over time

Hover for exact values · drag to zoom · double-click to reset

Readings (3)
DateValueMinMax
2026-07-09 16:50 1.025 10
2026-07-09 16:51 1.018 10
2026-07-09 16:52 0.991 10