Serial 001969238

Tests4
Approved0
Failures4

Tests over time

Test history

DateMeasurement IDID recordArticleResult
2025-10-30 15:11 40014 638974302405947979-6577 S0001055 Fail View
2025-10-30 15:12 40015 638974303027641506-8617 S0001055 Fail View
2026-07-09 13:00 77658 639191988090584344-2096 S0001055 Fail View
2026-07-09 13:01 77659 639191988649435813-5253 S0001055 Fail View

Test 40015

Result
Fail
Date
2025-10-30 15:12
Article
S0001055
ID record
638974303027641506-8617
ID production
52267
Temperature
26.24
Humidity
35.36
Test duration
55
Error ID
385
Error text
TestSW: [ADC_PA2] sense C

Measurement lines

StepNameValueMinMaxResult
0.0 Dekódování a uložení načteného SN 001969238 Pass
0.1 Uložení čísla výrobního příkazu 52267 Pass
0.2 Uložení ID obsluhy 1358 Pass
0.3 Uložení teploty okolí 26.24 Pass
0.4 Uložení vlhkosti okolí 35.36 Pass
0.5 Uložení Id testeru (uloženo na lokálním disku) Vez_Hokami_01-v01.01 Pass
0.6 Uložení id Artiklu (produktové číslo) S0001055 Pass
1.1 DMM: Kontrola hodnoty Odporu (TP6/TP4) 0.695800681 < 10 Pass
1.2 DMM: Kontrola hodnoty Odporu (TP6/TP5) 1000.32331 800 1200 Pass
3.1 NZ3.1: Měření napětí: Zkrat? 28.00651 > 27.9 Pass
3.2 NZ3.1: Měření proudu: Kontrola odběru 0.0003431591 < 0.005 Pass
3.3 R11.12: Zapnutí (TP42/TP43) Pass
3.4 NZ3.1: Měření napětí: Zkrat? 28.00651 > 27.9 Pass
3.5 NZ3.1: Měření proudu: Kontrola odběru 0.02435112 < 0.04 Pass
4.1 DMM: Měření napětí: +BATT (TP49/TP44) 27.9740306 27.9 28.1 Pass
4.2 DMM: Měření napětí: +BATT (TP49/TP34) 27.9969656 27.9 28.1 Pass
4.3 DMM: Měření napětí: +12V (TP49/TP46) 11.8065277 11 12.2 Pass
4.4 DMM: Měření napětí: +5V (TP49/TP7) 5.01784873 4.9 5.1 Pass
4.5 DMM: Měření napětí: +3V3 (TP49/TP16) 3.30180156 3.2 3.4 Pass
4.6 DMM: Měření napětí: VDDA +3V3 (TP49/TP2) 3.30180275 3.2 3.4 Pass
4.7 DMM: Měření napětí: (TP49/TP8) 4.69604739 4.57 4.77 Pass
4.8 DMM: Měření napětí: (TP49/TP9) 4.69165335 4.57 4.77 Pass
4.9 DMM: Měření napětí: (TP49/TP10) 4.69292259 4.57 4.77 Pass
5.1 DMM: Měření napětí: (TP49/TP46) 0.555830781 < 1 Pass
5.2 DMM: Měření napětí: (TP49/TP46) 11.7276159 > 11.5 Pass
6.1 R9.12: Vypnutí (TP49/TP28) Pass
7.1 NZ3: Měření napětí: Zkrat? 28.00651 > 27.9 Pass
7.2 NZ3: Měření proudu: Kontrola odběru 0.02562711 < 0.06 Pass
7.3 R0.6: Zapnutí Ext. Programátoru Pass
8.1 TestSw: Ověření komunikace [TYP:AA NAME:eDrive NAME2:TestSW HW:Kolecko v4 SW: Pass
9.1 TestSW: [CHG_SIG (PC14)] = log1? 16384 16384 16384 Pass
9.2 EL1.1: Ověření proudu na zátěži -> Current? 2.056885 1.6 2.8 Pass
9.3 DMM: Měření napětí: Vstup U14 (TP39/TP32) 29.5697839 29 30.1 Pass
9.4 DMM: Měření napětí: Vstup U14 (TP39/TP33) 11.3146243 10.8 11.5 Pass
9.5 DMM: Měření napětí: Vstup U14 (TP39/TP40) 1.64588836 1.5 1.8 Pass
10.1 NZ3.1: Měření napětí: Zkrat? 28.00651 > 27.9 Pass
10.2 NZ3.1: Měření proudu: Kontrola odběru 0.02552984 < 0.06 Pass
10.3 TestSW: [ADC_PA03] 3869 3667 3937 Pass
12.1 TestSW: [PA15] - napájení sense ABC Pass
12.2 TestSW: [HALL_A (PB4)] = log0? 0 0 0 Pass
12.3 TestSW: [HALL_A (PB4)] = log1? 16 16 16 Pass
12.4 TestSW: [HALL_B (PB5)] = log0? 0 0 0 Pass
12.5 TestSW: [HALL_B (PB5)] = log1? 32 32 32 Pass
12.6 TestSW: [HALL_C (PB0)] = log0? 0 0 0 Pass
12.7 TestSW: [HALL_C (PB0)] = log1? 1 1 1 Pass
13.1 TestSW: [CON_ID (PC13)] = log1? 8192 8192 8192 Pass
13.10 TestSW: [BTN_FFWD][ADC_PA6]? 4085 4000 4096 Pass
13.11 TestSW: [BTN_FFWD][ADC_PA6]? 2031 1900 2100 Pass
13.12 TestSW: [BTN_STOP][ADC_PA5]? 4085 4000 4096 Pass
13.13 TestSW: [BTN_STOP][ADC_PA5]? 2039 1900 2100 Pass
13.2 TestSW: [CON_ID (PC13)] = log0? 0 0 0 Pass
13.3 TestSW: [BTN_DRV][PA11] na log1 Pass
13.4 TestSW: [BTN_FWD][ADC_PB1]? 4085 4000 4096 Pass
13.5 TestSW: [BTN_FWD][ADC_PB1]? 2010 1900 2100 Pass
13.6 TestSW: [BTN_REV][ADC_PA4]? 4085 4000 4096 Pass
13.7 TestSW: [BTN_REV][ADC_PA4]? 2039 1900 2100 Pass
13.8 TestSW: [BTN_ULCK][ADC_PA7]? 4085 4000 4096 Pass
13.9 TestSW: [BTN_ULCK][ADC_PA7]? 2034 1900 2100 Pass
14.1 TestSW: [LED1][PB2] na log1 Pass
14.10 DMM: Měření napětí: LED3 (TP49/TP14) 3.29762069 > 3 Pass
14.11 TestSW: [LED3][PB11] na log0 Pass
14.12 DMM: Měření napětí: LED3 (TP49/TP14) 0.00353873828 < 0.1 Pass
14.13 TestSW: [LED4][PB12] na log1 Pass
14.14 DMM: Měření napětí: LED4 (TP49/TP12) 3.298912 > 3 Pass
14.15 TestSW: [LED4][PB12] na log0 Pass
14.16 DMM: Měření napětí: LED4 (TP49/TP12) 0.00351346652 < 0.1 Pass
14.2 DMM: Měření napětí: LED1 (TP49/TP13) 3.29737473 > 3 Pass
14.3 TestSW: [LED1][PB2] na log0 Pass
14.4 DMM: Měření napětí: LED1 (TP49/TP13) 0.00367965823 < 0.1 Pass
14.5 TestSW: [LED2][PB10] na log1 Pass
14.6 DMM: Měření napětí: LED1 (TP49/TP11) 3.29756145 > 3 Pass
14.7 TestSW: [LED2][PB10] na log0 Pass
14.8 DMM: Měření napětí: LED1 (TP49/TP11) 0.00355498062 < 0.1 Pass
14.9 TestSW: [LED3][PB11] na log1 Pass
15.1 TestSW: ntc 77 49 90 Pass
16.1 DMM: Měření frekvence (TP49/TP55) 19995.2233 19600 20400 Pass
16.2 DMM: Měření frekvence (TP49/TP56) 19995.221 19600 20400 Pass
16.3 DMM: Měření napětí (TP49/TP52) 14.0056615 13.3 14.7 Pass
17.1 DMM: Měření frekvence (TP49/TP61) 19995.2191 19600 20400 Pass
17.2 DMM: Měření frekvence (TP49/TP62) 19995.221 19600 20400 Pass
17.3 DMM: Měření napětí (TP49/TP58) 14.0053345 13.3 14.7 Pass
18.1 DMM: Měření frekvence (TP49/TP67) 19995.2172 19600 20400 Pass
18.2 DMM: Měření frekvence (TP49/TP68) 19995.221 19600 20400 Pass
18.3 DMM: Měření napětí (TP49/TP58) 14.0049955 13.3 14.7 Pass
19.1 DMM: Měření napětí: +5V (TP49/TP7) 0.0111602017 < 0.5 Pass
20.0.1 TestSW: [ADC_PA0] sense A do var VA = 2280 Pass
20.0.2 TestSW: [ADC_PA1] sense B do var VB = 2272 Pass
20.0.3 TestSW: [ADC_PA2] sense C do var VC = 2279 Pass
20.0.5 Analysis: VA VA[2280] 2210 2340 Pass
20.0.6 Analysis: VB VB[2272] 2210 2340 Pass
20.0.7 Analysis: VC VC[2279] 2210 2340 Pass
20.1 NZ3.1: Měření napětí: Zkrat? 28.00851 > 27.9 Pass
20.1.1 EL1.2: Ověření proudu na zátěži -> Current? 4.98971 4.7 5.3 Pass
20.1.2 TestSW: [ADC_PA0] sense A 2461 2445[VA] 2545[VA] Pass
20.1.3 TestSW: [ADC_PA1] sense B 2093 2007[VB] 2107[VB] Pass
20.1.4 TestSW: [ADC_PA2] sense C 2279 2210 2340 Pass
20.2 NZ3.1: Měření proudu: Kontrola odběru 0.03855196 < 0.06 Pass
20.2.1 EL1.2: Ověření proudu na zátěži -> Current? 4.989779 4.7 5.3 Pass
20.2.2 TestSW: [ADC_PA0] sense A 2098 2015[VA] 2115[VA] Pass
20.2.3 TestSW: [ADC_PA1] sense B 2449 2437[VB] 2537[VB] Pass
20.2.4 TestSW: [ADC_PA2] sense C 2279 2210 2340 Pass
20.3.1 EL1.2: Ověření proudu na zátěži -> Current? 4.989677 4.7 5.3 Pass
20.3.2 TestSW: [ADC_PA0] sense A 2461 2445[VA] 2545[VA] Pass
20.3.3 TestSW: [ADC_PA1] sense B 2274 2210 2340 Pass
20.3.4 TestSW: [ADC_PA2] sense C 1986 2014[VC] 2114[VC] Fail

Measurements over time

Hover for exact values · drag to zoom · double-click to reset

Readings (2)
DateValueMinMax
2026-07-09 13:00 1.069 10
2026-07-09 13:01 1.029 10