Serial 001791556

Tests11
Approved1
Failures10

Tests over time

Test history

DateMeasurement IDID recordArticleResult
2024-09-09 07:34 303 638614567935250894-9843 S0001055 Fail View
2024-09-09 07:47 304 638614576174253204-4001 S0001055 Fail View
2024-09-23 09:04 513 638626718023733530-4255 S0001055 Fail View
2024-12-05 15:11 5407 638690046054650320-1766 S0001055 Fail View
2024-12-05 15:33 5408 638690059428179741-4029 S0001055 Fail View
2025-09-05 11:20 25764 638926607643503145-2703 S0001055 Fail View
2025-11-06 17:34 40588 638980436179135332-9537 S0001055 Fail View
2026-07-09 14:55 77749 639192056731863485-6591 S0001055 Fail View
2026-07-09 15:26 77771 639192075495091633-7038 S0001055 Fail View
2026-08-11 04:53 81273 639220208058021312-8806 S0001055 Fail View
2026-08-11 04:54 81274 639220208321411482-3530 S0001055 Pass View

Test 303

Result
Fail
Date
2024-09-09 07:34
Article
S0001055
ID record
638614567935250894-9843
ID production
49267
Temperature
28,15
Humidity
49,95
Test duration
55
Error ID
385
Error text
TestSW: [ADC_PA2] sense C

Measurement lines

StepNameValueMinMaxResult
0.3 Uložení teploty okolí 28,15 Pass
0.4 Uložení vlhkosti okolí 49,95 Pass
0.5 Uložení Id testeru (uloženo na lokálním disku) Vez_Hokami_01-v01.01 Pass
0.6 Uložení id Artiklu (produktové číslo) S0001055 Pass
1.1 DMM: Kontrola hodnoty Odporu (TP6/TP4) 0,664135006 < 10 Pass
1.2 DMM: Kontrola hodnoty Odporu (TP6/TP5) 999,126454 800 1200 Pass
3.1 NZ3.1: Měření napětí: Zkrat? 28,00651 > 27,9 Pass
3.2 NZ3.1: Měření proudu: Kontrola odběru 0,001353928 < 0,005 Pass
3.3 R11.12: Zapnutí (TP42/TP43) Pass
3.4 NZ3.1: Měření napětí: Zkrat? 28,00851 > 27,9 Pass
3.5 NZ3.1: Měření proudu: Kontrola odběru 0,02401221 < 0,04 Pass
4.1 DMM: Měření napětí: +BATT (TP49/TP44) 27,9807122 27,9 28,1 Pass
4.2 DMM: Měření napětí: +BATT (TP49/TP34) 27,9991492 27,9 28,1 Pass
4.3 DMM: Měření napětí: +12V (TP49/TP46) 11,7392003 11 12,2 Pass
4.4 DMM: Měření napětí: +5V (TP49/TP7) 4,98873918 4,9 5,1 Pass
4.5 DMM: Měření napětí: +3V3 (TP49/TP16) 3,2897158 3,2 3,4 Pass
4.6 DMM: Měření napětí: VDDA +3V3 (TP49/TP2) 3,28972353 3,2 3,4 Pass
4.7 DMM: Měření napětí: (TP49/TP8) 4,66913946 4,57 4,77 Pass
4.8 DMM: Měření napětí: (TP49/TP9) 4,66670506 4,57 4,77 Pass
4.9 DMM: Měření napětí: (TP49/TP10) 4,66717762 4,57 4,77 Pass
5.1 DMM: Měření napětí: (TP49/TP46) 0,533783262 < 1 Pass
5.2 DMM: Měření napětí: (TP49/TP46) 11,6558548 > 11,5 Pass
6.1 R9.12: Vypnutí (TP49/TP28) Pass
7.1 NZ3: Měření napětí: Zkrat? 28,00851 > 27,9 Pass
7.2 NZ3: Měření proudu: Kontrola odběru 0,02385605 < 0,06 Pass
7.3 R0.6: Zapnutí Ext. Programátoru Pass
8.1 TestSw: Ověření komunikace [TYP:AA NAME:eDrive NAME2:TestSW HW:Kolecko v4 SW: Pass
9.1 TestSW: [CHG_SIG (PC14)] = log1? 16384 16384 16384 Pass
9.2 EL1.1: Ověření proudu na zátěži -> Current? 2,03112 1,6 2,8 Pass
9.3 DMM: Měření napětí: Vstup U14 (TP39/TP32) 29,6828343 29 30,1 Pass
9.4 DMM: Měření napětí: Vstup U14 (TP39/TP33) 11,2126514 10,8 11,5 Pass
9.5 DMM: Měření napětí: Vstup U14 (TP39/TP40) 1,62697983 1,5 1,8 Pass
10.1 NZ3.1: Měření napětí: Zkrat? 28,00851 > 27,9 Pass
10.2 NZ3.1: Měření proudu: Kontrola odběru 0,02523221 < 0,06 Pass
10.3 TestSW: [ADC_PA03] 3858 3667 3937 Pass
12.1 TestSW: [PA15] - napájení sense ABC Pass
12.2 TestSW: [HALL_A (PB4)] = log0? 0 0 0 Pass
12.3 TestSW: [HALL_A (PB4)] = log1? 16 16 16 Pass
12.4 TestSW: [HALL_B (PB5)] = log0? 0 0 0 Pass
12.5 TestSW: [HALL_B (PB5)] = log1? 32 32 32 Pass
12.6 TestSW: [HALL_C (PB0)] = log0? 0 0 0 Pass
12.7 TestSW: [HALL_C (PB0)] = log1? 1 1 1 Pass
13.1 TestSW: [CON_ID (PC13)] = log1? 8192 8192 8192 Pass
13.10 TestSW: [BTN_FFWD][ADC_PA6]? 4085 4000 4096 Pass
13.11 TestSW: [BTN_FFWD][ADC_PA6]? 2027 1900 2100 Pass
13.12 TestSW: [BTN_STOP][ADC_PA5]? 4085 4000 4096 Pass
13.13 TestSW: [BTN_STOP][ADC_PA5]? 2024 1900 2100 Pass
13.2 TestSW: [CON_ID (PC13)] = log0? 0 0 0 Pass
13.3 TestSW: [BTN_DRV][PA11] na log1 Pass
13.4 TestSW: [BTN_FWD][ADC_PB1]? 4084 4000 4096 Pass
13.5 TestSW: [BTN_FWD][ADC_PB1]? 2013 1900 2100 Pass
13.6 TestSW: [BTN_REV][ADC_PA4]? 4085 4000 4096 Pass
13.7 TestSW: [BTN_REV][ADC_PA4]? 2027 1900 2100 Pass
13.8 TestSW: [BTN_ULCK][ADC_PA7]? 4086 4000 4096 Pass
13.9 TestSW: [BTN_ULCK][ADC_PA7]? 2026 1900 2100 Pass
14.1 TestSW: [LED1][PB2] na log1 Pass
14.10 DMM: Měření napětí: LED3 (TP49/TP14) 3,2855965 > 3 Pass
14.11 TestSW: [LED3][PB11] na log0 Pass
14.12 DMM: Měření napětí: LED3 (TP49/TP14) 0,00352979738 < 0,1 Pass
14.13 TestSW: [LED4][PB12] na log1 Pass
14.14 DMM: Měření napětí: LED4 (TP49/TP12) 3,28684538 > 3 Pass
14.15 TestSW: [LED4][PB12] na log0 Pass
14.16 DMM: Měření napětí: LED4 (TP49/TP12) 0,00349734623 < 0,1 Pass
14.2 DMM: Měření napětí: LED1 (TP49/TP13) 3,28541997 > 3 Pass
14.3 TestSW: [LED1][PB2] na log0 Pass
14.4 DMM: Měření napětí: LED1 (TP49/TP13) 0,00363642633 < 0,1 Pass
14.5 TestSW: [LED2][PB10] na log1 Pass
14.6 DMM: Měření napětí: LED1 (TP49/TP11) 3,28556143 > 3 Pass
14.7 TestSW: [LED2][PB10] na log0 Pass
14.8 DMM: Měření napětí: LED1 (TP49/TP11) 0,00359548613 < 0,1 Pass
14.9 TestSW: [LED3][PB11] na log1 Pass
15.1 TestSW: ntc 58 49 90 Pass
16.1 DMM: Měření frekvence (TP49/TP55) 19994,9064 19600 20400 Pass
16.2 DMM: Měření frekvence (TP49/TP56) 19994,9046 19600 20400 Pass
16.3 DMM: Měření napětí (TP49/TP52) 14,0074221 13,3 14,7 Pass
17.1 DMM: Měření frekvence (TP49/TP61) 19994,897 19600 20400 Pass
17.2 DMM: Měření frekvence (TP49/TP62) 19994,9027 19600 20400 Pass
17.3 DMM: Měření napětí (TP49/TP58) 14,0063041 13,3 14,7 Pass
18.1 DMM: Měření frekvence (TP49/TP67) 19994,8992 19600 20400 Pass
18.2 DMM: Měření frekvence (TP49/TP68) 19994,903 19600 20400 Pass
18.3 DMM: Měření napětí (TP49/TP58) 14,0101317 13,3 14,7 Pass
19.1 DMM: Měření napětí: +5V (TP49/TP7) 0,00578984388 < 0,5 Pass
20.0.1 TestSW: [ADC_PA0] sense A do var VA = 2272 Pass
20.0.2 TestSW: [ADC_PA1] sense B do var VB = 2265 Pass
20.0.3 TestSW: [ADC_PA2] sense C do var VC = 2274 Pass
20.0.5 Analysis: VA VA[2272] 2210 2340 Pass
20.0.6 Analysis: VB VB[2265] 2210 2340 Pass
20.0.7 Analysis: VC VC[2274] 2210 2340 Pass
20.1 NZ3.1: Měření napětí: Zkrat? 28,00851 > 27,9 Pass
20.1.1 EL1.2: Ověření proudu na zátěži -> Current? 4,989644 4,7 5,3 Pass
20.1.2 TestSW: [ADC_PA0] sense A 2441 2437[VA] 2537[VA] Pass
20.1.3 TestSW: [ADC_PA1] sense B 2100 2000[VB] 2100[VB] Pass
20.1.4 TestSW: [ADC_PA2] sense C 2273 2210 2340 Pass
20.2 NZ3.1: Měření proudu: Kontrola odběru 0,0373909 < 0,06 Pass
20.2.1 EL1.2: Ověření proudu na zátěži -> Current? 4,989657 4,7 5,3 Pass
20.2.2 TestSW: [ADC_PA0] sense A 2103 2007[VA] 2107[VA] Pass
20.2.3 TestSW: [ADC_PA1] sense B 2431 2430[VB] 2530[VB] Pass
20.2.4 TestSW: [ADC_PA2] sense C 2274 2210 2340 Pass
20.3.1 EL1.2: Ověření proudu na zátěži -> Current? 4,989647 4,7 5,3 Pass
20.3.2 TestSW: [ADC_PA0] sense A 2441 2437[VA] 2537[VA] Pass
20.3.3 TestSW: [ADC_PA1] sense B 2269 2210 2340 Pass
20.3.4 TestSW: [ADC_PA2] sense C 2111 2009[VC] 2109[VC] Fail

Measurements over time

Hover for exact values · drag to zoom · double-click to reset

Readings (4)
DateValueMinMax
2026-07-09 14:55 1.006 10
2026-07-09 15:26 0.963 10
2026-08-11 04:53 0.84 10
2026-08-11 04:54 0.802 10