Testing Portal everyone (auth disabled)

Serial lookup

Search a serial number to see its full test history.

Serial 001609239

Tests8
Approved1
Failures7

Tests over time

Test history

DateMeasurement IDID recordArticleResult
2025-10-13 11:08 27560 638959433053318773-7796 S0000174 Fail View
2025-10-13 11:20 27561 638959439940550921-4185 S0000174 Fail View
2025-10-16 06:31 28257 638961859082789387-1076 S0000174 Fail View
2025-10-16 06:33 28258 638961859524402013-2985 S0000174 Fail View
2025-10-16 06:35 28259 638961860751394721-4365 S0000174 Fail View
2025-10-16 07:11 28260 638961882495277481-5735 S0000174 Fail View
2026-01-19 08:44 58382 639044054590936675-1546 S0000174 Fail View
2026-02-02 06:46 60712 639056079421296900-2730 S0000174 Pass View

Test 27561

Result
Fail
Date
2025-10-13 11:20
Article
S0000174
ID record
638959439940550921-4185
ID production
53729
Temperature
25.76
Humidity
38.94
Test duration
41
Error ID
433
Error text
NZ2: Odběr proudu ze zdroje (TP45/TP25,26)

Measurement lines

StepNameValueMinMaxResult
0.0 Dekódování a uložení načteného SN 001609239 Pass
0.1 Uložení čísla výrobního příkazu 53729 Pass
0.2 Uložení ID obsluhy 1950 Pass
0.3 Uložení teploty okolí 25.76 Pass
0.4 Uložení vlhkosti okolí 38.94 Pass
0.5 Uložení Id testeru (uloženo na lokálním disku) Vez_Hokami_01-v01.01 Pass
0.6 Uložení id Artiklu (produktové číslo) S0000174 Pass
1.1 DMM: Kontrola hodnoty Odporu (TP2/TP3) 998.70877 900 1100 Pass
1.2 DMM: Kontrola hodnoty Odporu (TP4/TP3) 999.251072 900 1100 Pass
1.3 DMM: Kontrola hodnoty Odporu (TP48/TP25,26) 1003.47937 900 1100 Pass
1.4 DMM: Kontrola hodnoty Odporu (TP13/TP25,26) 100405.789 90000 110000 Pass
2.1 DMM: Kontrola hodnoty Odporu (TP36/TP37) 1066.05005 1012 1120 Pass
2.2 DMM: Kontrola hodnoty Odporu (TP40/TP41) 1038.54475 1012 1120 Pass
4.0 DMM: Kontrola hodnoty napětí (TP22/TP25,26) -0.692079775 -0.75 -0.65 Pass
4.1 NZ1: Odběr proudu ze zdroje (TP25/TP25,26) 0.009986895 0.009 1 Pass
5.1 NZ1: Odběr proudu ze zdroje (TP22/TP25,26) 0.03104912 0.025 0.035 Pass
5.2 DMM: Kontrola hodnoty napětí (TP49/TP25,26) 8.77005994 8.7 9 Pass
5.3 DMM: Kontrola hodnoty napětí (TP17/TP25,26) 5.05490589 4.9 5.1 Pass
5.4 DMM: Kontrola hodnoty napětí (TP16/TP25,26) 5.00318272 4.9 5.1 Pass
5.5 DMM: Kontrola hodnoty napětí (TP29/TP25,26) 5.0032004 4.9 5.1 Pass
5.6 DMM: Kontrola hodnoty napětí (TP14/TP25,26) 3.30191031 3.2 3.4 Pass
5.7 DMM: Kontrola hodnoty napětí (TP5/TP25,26) 3.30189747 3.2 3.4 Pass
5.8 DMM: Kontrola hodnoty napětí (TP24/TP25,26) 8.69900299 7.5 9 Pass
5.9 DMM: Kontrola hodnoty napětí (TP20/TP25,26) 0.207651446 0 0.65 Pass
6.1 NZ1: Odběr proudu ze zdroje (TP25,26/TP19) 2.723677E-05 -0.0001 0.0001 Pass
6.2 DMM: Kontrola hodnoty napětí (TP20/TP25,26) 0.339805493 -0.2 0.5 Pass
6.3 NZ1: Odběr proudu ze zdroje (TP25,26/TP19) 0.01994655 0.019 1 Pass
7.1 NZ1: Odběr proudu ze zdroje (TP19/TP25,26) 2.723677E-05 0 0.0001 Pass
7.2 DMM: Kontrola hodnoty napětí (TP20/TP25,26) 6.00265618 5.95 7 Pass
7.3 DMM: Kontrola hodnoty napětí (TP50/TP25,26) 3.30206464 3.2 3.4 Pass
7.4 DMM: Kontrola hodnoty napětí (TP15/TP25,26) 0.135738214 0 0.5 Pass
7.5 NZ1: Odběr proudu ze zdroje (TP19/TP25,26) 0.0006150199 0.00057 0.00063 Pass
7.6 NZ2: Odběr proudu ze zdroje (TP42/TP25,26) 0.0001113352 -0.001 0.0002 Pass
7.7 NZ1: Odběr proudu ze zdroje (TP19/TP25,26) 2.723677E-05 -0.001 0.0001 Pass
7.8 DMM: Kontrola hodnoty napětí (TP38/TP25,26) 8.95370319 8.7 9 Pass
9.1 NZ1: Odběr proudu ze zdroje (TP22/TP25,26) 0.040421 0 0.099 Pass
9.1 analýza #OK Pass
10.2 NZ1: Odběr proudu ze zdroje (TP19/DLO) 2.723677E-05 -0.001 0.0002 Pass
10.3 NZ2: Odběr proudu ze zdroje (TP42/TP25,26) 9.580504E-05 -0.001 0.0002 Pass
10.4 NZ1: Odběr proudu ze zdroje (TP19/DLO) 0.02615093 0.015 0.03 Pass
11.1 DMM: Kontrola hodnoty proudu (TP25,26/NZ1-) 0.145487827 0.13 1 Pass
11.2 NZ1: Odběr proudu ze zdroje (TP19/DLO) 0.02246096 0.015 0.03 Pass
12.1 NZ2: Odběr proudu ze zdroje (TP22/TP25,26) 0.04288439 0.02 0.05 Pass
12.2 NZ1: Odběr proudu ze zdroje (TP19/DLO) 2.723677E-05 -0.001 0.0001 Pass
12.3 NZ1: Odběr proudu ze zdroje (TP19/DLO) 0.02249361 0.015 0.03 Pass
13.1 NZ1: Odběr proudu ze zdroje (TP19/DLO) -5.417849E-06 -0.001 0.0001 Pass
14.1 NZ1: Odběr proudu ze zdroje (TP22/TP25,26) 0.0453845 0.03 0.06 Pass
15.1 Test oscilátorů 0 (0x00) 0 (0x00) 0 (0x00) Pass
16.1 Test komunikace mezi U2 a U3 přes RS485 0 (0x00) 0 (0x00) 0 (0x00) Pass
17.1 Test eeprom a ověření velikosti 0 (0x00) 0 (0x00) 0 (0x00) Pass
17.2 Test SPI FLASH 0 (0x00) 0 (0x00) 255 (0xff) Pass
18.1 Analysis: hodnota na max True d_VCC_ADC[3397]<=d_max[3441.62522937691] Pass
19.1 Analysis: hodnota na max True d_U5V_ADC[3105]<=d_max[3126.00054286182] Pass
19.1 NZ2: Odběr proudu ze zdroje (TP19/TP25,26) 2.516567E-05 -0.0001 0.0001 Pass
19.2 DMM: Změřit napětí VBATT a uložit (TP20/TP25,26) VarDouble: d_VBATT = 5.98987786 Pass
19.3 Analysis: hodnota na max True d_VBATT_ADC[2326]<=d_max[2346.74491091718] Pass
20.1 NZ2: Odběr proudu ze zdroje (TP42/TP25,26) 0.0005137356 -0.0001 0.005 Pass
20.2 Přečti hodnotu PA4[HW_CH_DET] 0 0 0 Pass
20.3 DMM: Kontrola hodnoty napětí (TP38/TP25,26) 0.0187231867 0 0.49 Pass
20.4 DMM: Kontrola hodnoty napětí (TP38/TP25,26) 11.9432799 11.7 15 Pass
21.1 NZ2: Odběr proudu ze zdroje (TP39/TP25,26) 0.0002830348 -0.0001 0.001 Pass
21.2 DMM: Kontrola hodnoty napětí (TP43/TP25,26) 11.9287522 11.7 15 Pass
22.2 DMM: Kontrola hodnoty proudu (TP7/R15R) 0.180438904 0.15 0.185 Pass
22.2 DMM: Kontrola hodnoty proudu (TP7/R15R) 0 -0.0005 0.0005 Pass
25.1 NZ2: Odběr proudu ze zdroje (TP45/TP25,26) 5.14416E-05 0.195 0.22 Fail

Measurements over time

Hover for exact values · drag to zoom · double-click to reset

Readings (2)
DateValueMinMax
2026-01-19 08:44 1609239
2026-02-02 06:46 1609239