Serial lookup
Search a serial number to see its full test history.
Serial 001577078
Tests3
Approved1
Failures2
Tests over time
Test history
| Date | Measurement ID | ID record | Article | Result | |
|---|---|---|---|---|---|
| 2025-09-24 17:20 | 27012 | 638943240306931353-8512 | S0000690-1 | Fail | View |
| 2025-09-24 17:40 | 27013 | 638943252110855182-6535 | S0000690-1 | Fail | View |
| 2025-10-09 06:19 | 27487 | 638955802770946765-3475 | S0000690-1 | Pass | View |
Test 27012
- Result
- Fail
- Date
- 2025-09-24 17:20
- Article
- S0000690-1
- ID record
- 638943240306931353-8512
- ID production
- 52038
- Temperature
- 26.7
- Humidity
- 30.17
- Test duration
- 4
- Error ID
- 084
- Error text
- DMM: Měření napětí: +12V (TP1/TP72)
Measurement lines
| Step | Name | Value | Min | Max | Result |
|---|---|---|---|---|---|
| 0.1 | Uložení čísla výrobního příkazu | 52038 | Pass | ||
| 0.2 | Uložení ID obsluhy | 0395 | Pass | ||
| 0.3 | Uložení teploty okolí | 26.7 | Pass | ||
| 0.4 | Uložení vlhkosti okolí | 30.17 | Pass | ||
| 0.5 | Uložení Id testeru (uloženo na lokálním disku) | Vez_Hokami_01-v01.01 | Pass | ||
| 0.6 | Uložení id Artiklu (produktové číslo) | S0000690-1 | Pass | ||
| 1.1 | DMM: Měření napětí: +12V (TP1/TP72) | 0.271434133 | 11.8 | 12.3 | Fail |
Measurements over time
No plottable values for this measurement.
Readings (1)
| Date | Value | Min | Max |
|---|---|---|---|
| 2025-10-09 06:19 | — | — | — |