Serial lookup
Search a serial number to see its full test history.
Serial 001594744
Tests3
Approved0
Failures3
Tests over time
Test history
| Date | Measurement ID | ID record | Article | Result | |
|---|---|---|---|---|---|
| 2025-08-11 19:36 | 23973 | 638905305586506139-8319 | SB-VBB-050_P04 | Fail | View |
| 2025-08-11 19:36 | 23974 | 638905305825526618-1689 | SB-VBB-050_P04 | Fail | View |
| 2025-09-17 14:08 | 26701 | 638937076772401693-5918 | SB-VBB-050_P04 | Fail | View |
Test 26701
- Result
- Fail
- Date
- 2025-09-17 14:08
- Article
- SB-VBB-050_P04
- ID record
- 638937076772401693-5918
- ID production
- 48297
- Temperature
- 26.68
- Humidity
- 37.26
- Test duration
- 3
- Error ID
- 077
- Error text
- DMM: Měření napětí: +3V3_PERM (TP41/TP65)
Measurement lines
| Step | Name | Value | Min | Max | Result |
|---|---|---|---|---|---|
| 0.1 | Uložení čísla výrobního příkazu | 48297 | Pass | ||
| 0.2 | Uložení ID obsluhy | 0736 | Pass | ||
| 0.3 | Uložení teploty okolí | 26.68 | Pass | ||
| 0.4 | Uložení vlhkosti okolí | 37.26 | Pass | ||
| 0.5 | Uložení Id testeru (uloženo na lokálním disku) | Vez_Hokami_01-v01.01 | Pass | ||
| 0.6 | Uložení id Artiklu (produktové číslo) | SB-VBB-050_P04 | Pass | ||
| 0.6 | DMM: Status? | 0000000000000000 | xxxxxxxxx000000x | Pass | |
| 0.7 | NZ3: Status? | 0000000000000000 | xxxxxxxxx000000x | Pass | |
| 0.8 | EL: Status? | 0000000000000000 | xxxxxxxxx000000x | Pass | |
| 1.1 | NZ3: Měření napětí: Zkrat? | 1.815988 | < | 4.9 | Pass |
| 1.2 | DMM: Měření napětí: +3V3_PERM (TP41/TP65) | 2.88718959 | 3.25 | 3.35 | Fail |
Measurements over time
Hover for exact values · drag to zoom · double-click to reset
Readings (3)
| Date | Value | Min | Max |
|---|---|---|---|
| 2025-08-11 19:36 | 48297 | — | — |
| 2025-08-11 19:36 | 48297 | — | — |
| 2025-09-17 14:08 | 48297 | — | — |